메뉴 건너뛰기




Volumn 39, Issue 5, 2012, Pages 455-460

Classification of trace patterns of 226- and 1000-Hz tympanometry in healthy neonates

Author keywords

Hearing loss; Neonate; Tympanometry

Indexed keywords

ARTICLE; AUDITORY SCREENING; CLINICAL EVALUATION; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; EVOKED OTOACOUSTIC EMISSION; FALSE POSITIVE RESULT; FEMALE; HEARING LOSS; HUMAN; INTERMETHOD COMPARISON; MALE; MIDDLE EAR DISEASE; NEWBORN; NEWBORN ASSESSMENT; NEWBORN SCREENING; PURE TONE AUDIOMETRY; RISK FACTOR; SENSITIVITY AND SPECIFICITY; SENSORY ANALYSIS; SENSORY EVALUATION; TYMPANOMETRY;

EID: 84861804762     PISSN: 03858146     EISSN: 18791476     Source Type: Journal    
DOI: 10.1016/j.anl.2011.08.007     Document Type: Article
Times cited : (15)

References (22)
  • 1
    • 35148846825 scopus 로고    scopus 로고
    • Year 2007 position statement: principles and guidelines for early hearing detection and intervention programs
    • Year 2007 position statement: principles and guidelines for early hearing detection and intervention programs. Pediatrics 2007, 120:898-921.
    • (2007) Pediatrics , vol.120 , pp. 898-921
  • 2
    • 0017196534 scopus 로고
    • Tympanometric detection of middle ear effusion in infants and young children
    • Paradise J.L., Smith C.G., Bluestone C.D. Tympanometric detection of middle ear effusion in infants and young children. Pediatrics 1976, 58:198-210.
    • (1976) Pediatrics , vol.58 , pp. 198-210
    • Paradise, J.L.1    Smith, C.G.2    Bluestone, C.D.3
  • 3
    • 0025962885 scopus 로고
    • Developmental changes in multifrequency tympanograms
    • Holte L., Margolis R.H., Cavanaugh R.M. Developmental changes in multifrequency tympanograms. Audiology 1991, 30:1-24.
    • (1991) Audiology , vol.30 , pp. 1-24
    • Holte, L.1    Margolis, R.H.2    Cavanaugh, R.M.3
  • 4
    • 0027494672 scopus 로고
    • Ear-canal impedance and reflection coefficient in human infants and adults
    • Keefe D.H., Bulen J.C., Arehart K.H., Burns E.M. Ear-canal impedance and reflection coefficient in human infants and adults. J Acoust Soc Am 1993, 94:2617-2638.
    • (1993) J Acoust Soc Am , vol.94 , pp. 2617-2638
    • Keefe, D.H.1    Bulen, J.C.2    Arehart, K.H.3    Burns, E.M.4
  • 5
    • 0030861584 scopus 로고    scopus 로고
    • Developmental changes in tympanometry: a case study
    • Meyer S.E., Jardine C.A., Deverson W. Developmental changes in tympanometry: a case study. Br J Audiol 1997, 31:189-195.
    • (1997) Br J Audiol , vol.31 , pp. 189-195
    • Meyer, S.E.1    Jardine, C.A.2    Deverson, W.3
  • 7
    • 34249903785 scopus 로고    scopus 로고
    • Normative multifrequency tympanometry in infants and toddlers
    • Calandruccio L., Fitzgerald T.S., Prieve B.A. Normative multifrequency tympanometry in infants and toddlers. J Am Acad Audiol 2006, 17:470-480.
    • (2006) J Am Acad Audiol , vol.17 , pp. 470-480
    • Calandruccio, L.1    Fitzgerald, T.S.2    Prieve, B.A.3
  • 8
    • 0030070351 scopus 로고    scopus 로고
    • Tympanometry and otoacoustic emissions in a cohort of special care neonates
    • Sutton G.J., Gleadle P., Rowe S.J. Tympanometry and otoacoustic emissions in a cohort of special care neonates. Br J Audiol 1996, 30:9-17.
    • (1996) Br J Audiol , vol.30 , pp. 9-17
    • Sutton, G.J.1    Gleadle, P.2    Rowe, S.J.3
  • 11
    • 33748676850 scopus 로고    scopus 로고
    • Choice of probe tone and classification of trace patterns in tympanometry undertaken in early infancy
    • Baldwin M. Choice of probe tone and classification of trace patterns in tympanometry undertaken in early infancy. Int J Audiol 2006, 45:417-427.
    • (2006) Int J Audiol , vol.45 , pp. 417-427
    • Baldwin, M.1
  • 12
    • 0029336504 scopus 로고
    • Joint Committee on Infant Hearing 1994 Position Statement
    • Joint Committee on Infant Hearing 1994 Position Statement Int J Pediatr Otorhinolaryngol 1995, 32:265-274.
    • (1995) Int J Pediatr Otorhinolaryngol , vol.32 , pp. 265-274
  • 13
    • 0014528253 scopus 로고
    • The scope and application of current audiometric tests
    • Liden G. The scope and application of current audiometric tests. J Laryngol Otol 1969, 83:507-520.
    • (1969) J Laryngol Otol , vol.83 , pp. 507-520
    • Liden, G.1
  • 14
    • 0014868102 scopus 로고
    • Clinical experience with impedance audiometry
    • Jerger J. Clinical experience with impedance audiometry. Arch Otolaryngol 1970, 92:311-324.
    • (1970) Arch Otolaryngol , vol.92 , pp. 311-324
    • Jerger, J.1
  • 15
    • 0022537786 scopus 로고
    • Objective diagnosis of otitis media in early infancy by tympanometry and ipsilateral acoustic reflex thresholds
    • Marchant C.D., McMillan P.M., Shurin P.A., Johnson C.E., Turczyk V.A., Feinstein J.C., et al. Objective diagnosis of otitis media in early infancy by tympanometry and ipsilateral acoustic reflex thresholds. J Pediatr 1986, 109:590-595.
    • (1986) J Pediatr , vol.109 , pp. 590-595
    • Marchant, C.D.1    McMillan, P.M.2    Shurin, P.A.3    Johnson, C.E.4    Turczyk, V.A.5    Feinstein, J.C.6
  • 16
    • 0029859024 scopus 로고    scopus 로고
    • Maturation of the middle and external ears: acoustic power-based responses and reflectance tympanometry
    • Keefe D.H., Levi E. Maturation of the middle and external ears: acoustic power-based responses and reflectance tympanometry. Ear Hear 1996, 17:361-373.
    • (1996) Ear Hear , vol.17 , pp. 361-373
    • Keefe, D.H.1    Levi, E.2
  • 17
    • 41549162511 scopus 로고    scopus 로고
    • Measuring middle ear admittance in newborns using 1000Hz tympanometry: a comparison of methodologies
    • Kei J., Mazlan R., Hickson L., Gavranich J., Linning R. Measuring middle ear admittance in newborns using 1000Hz tympanometry: a comparison of methodologies. J Am Acad Audiol 2007, 18:739-748.
    • (2007) J Am Acad Audiol , vol.18 , pp. 739-748
    • Kei, J.1    Mazlan, R.2    Hickson, L.3    Gavranich, J.4    Linning, R.5
  • 18
    • 34548226062 scopus 로고    scopus 로고
    • Evaluation of middle ear function in young children: clinical guidelines for the use of 226- and 1000-Hz tympanometry
    • Alaerts J., Luts H., Wouters J. Evaluation of middle ear function in young children: clinical guidelines for the use of 226- and 1000-Hz tympanometry. Otol Neurotol 2007, 28:727-732.
    • (2007) Otol Neurotol , vol.28 , pp. 727-732
    • Alaerts, J.1    Luts, H.2    Wouters, J.3
  • 19
    • 84861830691 scopus 로고    scopus 로고
    • Influence of middle ear conditions on measurement of evoked otoacoustic emissions
    • Park H.J., Goh E.K., Lee H.S., Jang H.J., Baek M.J., Yoon J.K., et al. Influence of middle ear conditions on measurement of evoked otoacoustic emissions. Korean J Otolaryngol 2001, 44:251-255.
    • (2001) Korean J Otolaryngol , vol.44 , pp. 251-255
    • Park, H.J.1    Goh, E.K.2    Lee, H.S.3    Jang, H.J.4    Baek, M.J.5    Yoon, J.K.6
  • 20
    • 0030808914 scopus 로고    scopus 로고
    • Neonatal hearing screening with otoscopy, auditory brain stem response, and otoacoustic emissions
    • Doyle K.J., Burggraaff B., Fujikawa S., Kim J., MacArthur C.J. Neonatal hearing screening with otoscopy, auditory brain stem response, and otoacoustic emissions. Otolaryngol Head Neck Surg 1997, 116:597-603.
    • (1997) Otolaryngol Head Neck Surg , vol.116 , pp. 597-603
    • Doyle, K.J.1    Burggraaff, B.2    Fujikawa, S.3    Kim, J.4    MacArthur, C.J.5
  • 21
    • 0027400220 scopus 로고
    • Abnormalities of the neonatal ear: otoscopic observations, histologic observations, and a model for contamination of the middle ear by cellular contents of amniotic fluid
    • Eavey R.D. Abnormalities of the neonatal ear: otoscopic observations, histologic observations, and a model for contamination of the middle ear by cellular contents of amniotic fluid. Laryngoscope 1993, 103(1 Pt 2 Suppl. 58):1-31.
    • (1993) Laryngoscope , vol.103 , Issue.1 PART 2 SUPPL. 58 , pp. 1-31
    • Eavey, R.D.1
  • 22
    • 77249176125 scopus 로고    scopus 로고
    • Tympanometry in infants with middle ear effusion having been identified using spiral computerized tomography
    • Zhiqi L., Kun Y., Zhiwu H. Tympanometry in infants with middle ear effusion having been identified using spiral computerized tomography. Am J Otolaryngol 2010, 31:96-103.
    • (2010) Am J Otolaryngol , vol.31 , pp. 96-103
    • Zhiqi, L.1    Kun, Y.2    Zhiwu, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.