메뉴 건너뛰기




Volumn , Issue , 2011, Pages 7492-7495

Overview of the boston retinal prosthesis: Challenges and opportunities to restore useful vision to the blind

Author keywords

[No Author keywords available]

Indexed keywords

ANALOG TO DIGITAL CONVERTERS; CIRCUIT COMPONENTS; CURRENT DRIVERS; ELECTRODE IMPEDANCE; EXTERNAL SOURCES; FINAL ASSEMBLY; IMPLANTED DEVICE; IN-VITRO; IN-VIVO; OUTPUT VOLTAGES; PHYSIOLOGICAL SALINE; PRE-CLINICAL; RETINAL PROSTHESIS; SPUTTERED IRIDIUM OXIDE; STIMULATING ELECTRODES; STIMULATION PULSE; TELEMETRY CHANNELS; YUCATAN MINI-PIGS;

EID: 84861666632     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/IEMBS.2011.6093610     Document Type: Conference Paper
Times cited : (26)

References (21)
  • 4
    • 0345445897 scopus 로고    scopus 로고
    • Perceptual efficacy of electrical stimulation of human retina with a microelectrode array during short-term surgical trials
    • J.F. Rizzo III, J. Wyatt, J. Loewenstein, S. Kelly, and D. Shire, "Perceptual Efficacy of Electrical Stimulation of Human Retina with a Microelectrode Array During Short-Term Surgical Trials," Invest. Ophthalmol. Vis. Sci., vol. 44, 2003, pp. 5362-5369.
    • (2003) Invest. Ophthalmol. Vis. Sci. , vol.44 , pp. 5362-5369
    • Rizzo Iii., J.F.1    Wyatt, J.2    Loewenstein, J.3    Kelly, S.4    Shire, D.5
  • 5
    • 0345014794 scopus 로고    scopus 로고
    • Methods and perceptual thresholds for short-term electrical stimulation of human retina with microelectrode arrays
    • J.F. Rizzo III, J. Wyatt, J. Loewenstein, S. Kelly, and D. Shire, "Methods and Perceptual Thresholds for Short-Term Electrical Stimulation of Human Retina with Microelectrode Arrays," Invest. Ophthalmol. Vis. Sci., vol. 44, 2003, pp. 5355-5361.
    • (2003) Invest. Ophthalmol. Vis. Sci. , vol.44 , pp. 5355-5361
    • Rizzo Iii., J.F.1    Wyatt, J.2    Loewenstein, J.3    Kelly, S.4    Shire, D.5
  • 7
    • 33847669848 scopus 로고    scopus 로고
    • Experimental implantation of epiretinal retina implants (EPI-RET) with an IOL-type receiver unit
    • H. Gerding, F.P. Benner, S. Taneri, "Experimental Implantation of Epiretinal Retina Implants (EPI-RET) With an IOL-Type Receiver Unit," J. Neural Eng., vol. 4, 2007, pp. S38-S49.
    • (2007) J. Neural Eng. , vol.4
    • Gerding, H.1    Benner, F.P.2    Taneri, S.3
  • 9
    • 31044443749 scopus 로고    scopus 로고
    • Implantation and testing of subretinal film electrodes in domestic pigs
    • T. Schanze, H.G. Sachs, C. Wiesenack, U. Brunner, H. Sailer, "Implantation and Testing of Subretinal Film Electrodes in Domestic Pigs," Exp. Eye Res., vol. 82, 2006, pp. 332-340.
    • (2006) Exp. Eye Res. , vol.82 , pp. 332-340
    • Schanze, T.1    Sachs, H.G.2    Wiesenack, C.3    Brunner, U.4    Sailer, H.5
  • 10
    • 41149178026 scopus 로고    scopus 로고
    • A suprachoroidal electrical retinal stimulator design for long-term animal experiments and in-vivo assessment of its feasibility and biocompatibility in rabbits
    • J.A. Zhou, S.J. Woo, S.I. Park, E.T. Kim, J.M. Seo, H. Chung, S.J. Kim, "A Suprachoroidal Electrical Retinal Stimulator Design for Long-Term Animal Experiments and In-Vivo Assessment of Its Feasibility and Biocompatibility in Rabbits," J. Biomed. Biotech., vol. 2008, pp. 547428-1 - 547428-10.
    • (2008) J. Biomed. Biotech. , pp. 5474281-54742810
    • Zhou, J.A.1    Woo, S.J.2    Park, S.I.3    Kim, E.T.4    Seo, J.M.5    Chung, H.6    Kim, S.J.7
  • 13
    • 70350186466 scopus 로고    scopus 로고
    • The IMI retinal implant system
    • M.S. Humayun, J.D. Weiland, G. Chader, E. Greenbaum, Eds., Biomedical Engineering, and Clinical Advances, New York, Springer
    • R. Hornig, T. Zehnder, M. Velikey-Parel, T. Laube, M. Feucht, G. Richard, "The IMI Retinal Implant System," in M.S. Humayun, J.D. Weiland, G. Chader, E. Greenbaum, eds., Artificial Sight: Basic Research, Biomedical Engineering, and Clinical Advances, New York: Springer, 2007, pp. 111-128.
    • (2007) Artificial Sight: Basic Research , pp. 111-128
    • Hornig, R.1    Zehnder, T.2    Velikey-Parel, M.3    Laube, T.4    Feucht, M.5    Richard, G.6
  • 14
    • 65549142134 scopus 로고    scopus 로고
    • Restoring neuroretinal function: New potentials
    • E. Zrenner, "Restoring Neuroretinal Function: New Potentials," Doc. Ophthalmol., vol. 115, 2007, pp. 56-59.
    • (2007) Doc. Ophthalmol. , vol.115 , pp. 56-59
    • Zrenner, E.1
  • 17
    • 33847649689 scopus 로고    scopus 로고
    • Responses of ganglion cells to repetitive electrical stimulation of the retina
    • R.J. Jensen, J.F. Rizzo III, "Responses of Ganglion Cells to Repetitive Electrical Stimulation of the Retina," J. Neural Eng., vol. 4, 2007, pp. S1-S6.
    • (2007) J. Neural Eng. , vol.4
    • Jensen, R.J.1    Rizzo Iii., J.F.2
  • 19
    • 54049125391 scopus 로고    scopus 로고
    • A low-power fully implantable 15-channel retinal stimulator chip
    • L.S. Theogarajan, "A Low-Power Fully Implantable 15-Channel Retinal Stimulator Chip," IEEE J. Solid-State Circuits, vol. 43, 2008, pp. 2322-2337.
    • (2008) IEEE J. Solid-State Circuits , vol.43 , pp. 2322-2337
    • Theogarajan, L.S.1
  • 20
    • 67649884471 scopus 로고    scopus 로고
    • Extraction of a chronically-implanted, microfabricated, subretinal electrode array
    • J. Chen, H.A. Shah, C. Herbert, J.I. Loewenstein, J.F. Rizzo, "Extraction of a Chronically-Implanted, Microfabricated, Subretinal Electrode Array," Ophthalmic Res., vol. 43, No. 3, 2009, pp. 128- 137.
    • (2009) Ophthalmic Res. , vol.43 , Issue.3 , pp. 128-137
    • Chen, J.1    Shah, H.A.2    Herbert, C.3    Loewenstein, J.I.4    Rizzo, J.F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.