메뉴 건너뛰기




Volumn 45, Issue 1-2, 2012, Pages 41-52

Effect of reinforcement on plastic shrinkage and settlement of self-consolidating concrete as repair material

Author keywords

Repair concrete; Restrained plastic settlement; Restrained plastic shrinkage; Self consolidating concrete

Indexed keywords

BLEEDING RATE; CONCRETE BLEEDING; CONCRETE STRAIN; CONCRETE SUBSTRATES; CONTROLLING FACTORS; EVAPORATION RATE; EXPERIMENTAL INVESTIGATIONS; LARGE DIAMETER; PLASTIC SHRINKAGE; REINFORCING BAR; REPAIR MATERIALS; RESTRAINED PLASTIC SETTLEMENT; RESTRAINED PLASTIC SHRINKAGE; RESTRAINT CONDITIONS; SELF-CONSOLIDATING CONCRETE; SETTLEMENT BEHAVIORS; STEEL BARS;

EID: 84861655491     PISSN: 13595997     EISSN: None     Source Type: Journal    
DOI: 10.1617/s11527-011-9747-4     Document Type: Article
Times cited : (21)

References (14)
  • 1
    • 25444479176 scopus 로고    scopus 로고
    • Prediction of restrained shrinkage based on restraint factors in patching repair mortar
    • DOI 10.1016/j.cemconres.2004.11.020, PII S0008884605000736
    • Abbasnia R, Ghoddousi P, Ahmadi J (2005) Prediction of restrained shrinkage based on restraint factors in patching repair mortar. Cem Concr Res 35:1909-1913 (Pubitemid 41375770)
    • (2005) Cement and Concrete Research , vol.35 , Issue.10 , pp. 1909-1913
    • Abbasnia, R.1    Godossi, P.2    Ahmadi, J.3
  • 3
    • 2542491571 scopus 로고    scopus 로고
    • The effect of reinforcement on early-age cracking due to autogenous shrinkage and thermal effects
    • Sule M, Breugel KV (2004) The effect of reinforcement on early-age cracking due to autogenous shrinkage and thermal effects. Cem Concr Compos 26:581-587
    • (2004) Cem Concr Compos , vol.26 , pp. 581-587
    • Sule, M.1    Breugel, K.V.2
  • 5
    • 1842533351 scopus 로고    scopus 로고
    • Effect of y type polypropylene fiber on plastic shrinkage cracking of cement mortar
    • Ma Y, Tan ZM, Wu K (2004) Effect of Y type polypropylene fiber on plastic shrinkage cracking of cement mortar. Mater Struct 37:92-95
    • (2004) Mater Struct , vol.37 , pp. 92-95
    • Ma, Y.1    Tan, Z.M.2    Wu, K.3
  • 7
    • 34250862111 scopus 로고    scopus 로고
    • A quantitative study on the plastic shrinkage cracking in high strength hybrid fibre reinforced concrete
    • DOI 10.1016/j.cemconcomp.2007.03.005, PII S0958946507000558
    • Sivakumar A, Santhanam M (2007) A quantitative study on the plastic shrinkage cracking in high strength hybrid fiber reinforced concrete. Cem Concr Compos 29:575-581 (Pubitemid 46977226)
    • (2007) Cement and Concrete Composites , vol.29 , Issue.7 , pp. 575-581
    • Sivakumar, A.1    Santhanam, M.2
  • 8
    • 33748526879 scopus 로고    scopus 로고
    • Evaluation of plastic shrinkage cracking of self-consolidating concrete
    • Turcry P, Loukili A (2006) A evaluation of plastic shrinkage cracking of self-consolidating concrete. ACI Mater J 103(4):272-279 (Pubitemid 44368795)
    • (2006) ACI Materials Journal , vol.103 , Issue.4 , pp. 272-279
    • Turcry, P.1    Loukili, A.2
  • 9
    • 84861415679 scopus 로고    scopus 로고
    • Durability of self-consolidating concrete used in repair applications
    • Duran-Herrera A, FIC-UANL Academic Group on Concrete Technology, Mexico (eds)
    • Khayat KH, Hwang SD (2005) Durability of self-consolidating concrete used in repair applications. In: Duran-Herrera A, FIC-UANL Academic Group on Concrete Technology, Mexico (eds) Proceedings of the international symposium on durability of concrete, pp 121-141
    • (2005) Proceedings of the International Symposium on Durability of Concrete , pp. 121-141
    • Khayat, K.H.1    Hwang, S.D.2
  • 11
    • 84861662192 scopus 로고
    • Standard test method for bleeding
    • ASTM Standard Designation C 232, vol 4.02. ASTM, Pennsylvania
    • ASTM Standard Designation C 232 (1992) Standard test method for bleeding. Annual book of ASTM standards, vol 4.02. ASTM, Pennsylvania
    • (1992) Annual Book of ASTM Standards
  • 12
    • 0038448648 scopus 로고    scopus 로고
    • Effect of silica fume on the plastic shrinkage and pore water pressure of high-strength concretes
    • DOI 10.1617/13751
    • Hammer TA (2001) Effect of silica fume on the plastic shrinkage and pore water pressure of high-strength concretes. Mater Struct 34:273-278 (Pubitemid 33700815)
    • (2001) Materials and Structures/Materiaux et Constructions , vol.34 , Issue.239 , pp. 273-278
    • Hammer, T.A.1
  • 13
    • 84861398879 scopus 로고    scopus 로고
    • A comparison between plastic shrinkage of concrete containing silica fume and the normal concrete
    • Ghoddousi P, Raiss ghasemi AM, Parhizkar T (2007) A comparison between plastic shrinkage of concrete containing silica fume and the normal concrete. Int J Civ Eng (IUST) 5(4):266-273
    • (2007) Int J Civ Eng (IUST) , vol.5 , Issue.4 , pp. 266-273
    • Ghoddousi, P.1    Raiss Ghasemi, A.M.2    Parhizkar, T.3
  • 14
    • 0029779063 scopus 로고    scopus 로고
    • Plastic shrinkage cracking of normal and high-strength concrete: A comparative study
    • Samman T, Mirza WH, Wafa FF (1996) Plastic shrinkage cracking of normal and high-strength concrete: a comparative study. ACI Mater J 93(1):36-40 (Pubitemid 126516183)
    • (1996) ACI Materials Journal , vol.93 , Issue.1 , pp. 36-40
    • Samman, T.A.1    Mirza, W.H.2    Wafa, F.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.