메뉴 건너뛰기




Volumn 17, Issue 6, 2011, Pages 1012-1029

Distributed thermal response tests on a multi-pipe coaxial borehole heat exchanger

Author keywords

[No Author keywords available]

Indexed keywords

ALL DISTRIBUTED; BOREHOLE HEAT EXCHANGERS; FIBEROPTIC CABLES; FLOW REGIMES; GROUND THERMAL CONDUCTIVITY; HEAT INJECTION; LEG-TYPE; LINE SOURCES; LOCAL VARIATIONS; THERMAL POWER; THERMAL RESPONSE; THERMAL RESPONSE TEST; THERMAL SHUNT; VOLUMETRIC FLOW RATE;

EID: 84861615998     PISSN: 10789669     EISSN: None     Source Type: Journal    
DOI: 10.1080/10789669.2011.625304     Document Type: Article
Times cited : (36)

References (17)
  • 1
    • 84861612786 scopus 로고    scopus 로고
    • Licentiate of engineering thesis. The Royal Institute of Technology KTH, Stockholm, Sweden
    • Acuña, J. 2010. Improvements of U-pipe borehole heat exchangers. Licentiate of engineering thesis. The Royal Institute of Technology KTH, Stockholm, Sweden.
    • (2010) Improvements of U-pipe Borehole Heat Exchangers
    • Acuña, J.1
  • 5
    • 84861612784 scopus 로고    scopus 로고
    • Erdwärme-Systemtechnik GmbH & Co. KG, Brief report on Deliverable 8, design drafts, description of pre-prototype borehole heat exchanger
    • Erdwärme-Systemtechnik GmbH & Co. KG. 2006. GROUND-HIT. Brief report on Deliverable 8, design drafts, description of pre-prototype borehole heat exchanger.
    • (2006) Ground-Hit
  • 6
    • 34548172920 scopus 로고    scopus 로고
    • Thermal response tests using optical fiber thermometers
    • Geothermal Resources Council Transactions - GRC 2006 Annual Meeting: Geothermal Resources-Securing Our Energy Future
    • Fujii, H., H. Okubo, and R. Itoi. 2006. Thermal response tests using optical fiber thermometers. GRC Transactions 30:545-51. (Pubitemid 47309468)
    • (2006) Transactions - Geothermal Resources Council , vol.30 , pp. 545-551
    • Fujii, H.1    Okubo, H.2    Itoi, R.3
  • 7
    • 70350402110 scopus 로고    scopus 로고
    • An improved thermal response test for U-tube ground heat exchanger based on optical fiber thermometers
    • Fujii H., H. Okubo, K. Nishi, R. Itoi, K. Ohyama, and K. Shibata. 2009. An improved thermal response test for U-tube ground heat exchanger based on optical fiber thermometers. Geothermics 38:399-406.
    • (2009) Geothermics , vol.38 , pp. 399-406
    • Fujii, H.1    Okubo, H.2    Nishi, K.3    Itoi, R.4    Ohyama, K.5    Shibata, K.6
  • 14
    • 0001848788 scopus 로고
    • Theory of ground pipe heat source for the heat pump
    • Ingersoll, L. R., and H. J. Plass. 1948. Theory of ground pipe heat source for the heat pump. ASHVE Transactions 5:339-48.
    • (1948) ASHVE Transactions , vol.5 , pp. 339-348
    • Ingersoll, L.R.1    Plass, H.J.2
  • 16
    • 0020949218 scopus 로고
    • Fluid to duct wall heat transfer in duct system heat storages
    • Mogensen, P. 1983. Fluid to duct wall heat transfer in duct system heat storages. International Conference on Subsurface Heat Storage in Theory and Practice. Stockholm, Sweden, Appendix, Part II, pp. 652-7. (Pubitemid 14614236)
    • (1983) Document - Swedish Council for Building Research , Issue.PART 2 , pp. 652-657
    • Mogensen Palme1
  • 17


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.