메뉴 건너뛰기




Volumn 11, Issue 1, 2012, Pages 169-176

A Comparative study between thermostat/hygrometer-based conventional and artificial neural network-based predictive/adaptive thermal controls in residential buildings

Author keywords

Adaptive controls; Artificial neural network; PMV control; Predictive controls; Thermal comfort

Indexed keywords

COMPUTER CIRCUITS; ENERGY EFFICIENCY; NEURAL NETWORKS; THERMAL COMFORT;

EID: 84861608239     PISSN: 13467581     EISSN: 13472852     Source Type: Journal    
DOI: 10.3130/jaabe.11.169     Document Type: Article
Times cited : (10)

References (22)
  • 2
    • 0036758568 scopus 로고    scopus 로고
    • Energy conservation in buildings through efficient A/C control using neural networks
    • Ben-Nakhi, A.E. and Mahmoud, M.A. (2002) Energy conservation in buildings through efficient A/C control using neural networks. Applied Energy, 73, pp.5-23.
    • (2002) Applied Energy , vol.73 , pp. 5-23
    • Ben-Nakhi, A.E.1    Mahmoud, M.A.2
  • 4
    • 84876672184 scopus 로고    scopus 로고
    • DWYER, Available from, 2004-10-15-17:35
    • DWYER (2008) HU-1142. Available from: http://omnicontrols.com/lists/DwyerRh.htm; 2004-10-15-17:35.
    • (2008) HU-1142
  • 5
    • 34648849604 scopus 로고    scopus 로고
    • National Semiconductor, Available from, 2008-11-29-11:00
    • National Semiconductor, LM35 Precision Centigrade Temperature Sensors, Available from: www.national.com; 2008-11-29-11:00.
    • LM35 Precision Centigrade Temperature Sensors
  • 6
    • 77649235720 scopus 로고    scopus 로고
    • Global Controls, Available from:, 2005-03-28-11:00
    • Global Controls (2005) EE70 Series. Available from: http://images.google.com/imgres?imgurl=http://www.global-controls.net/home/images/Airtest/Air%2520Velocity/EE70.gif&imgrefurl=http://www.global-controls.net/air_velocity.html&h=264&w=375&sz=35&tbnid=DzhOvOu6mtQJ:&tbnh=83&tbnw=118&start=12&prev=/images%3Fq%3Dee70%26hl%3Den%26lr%3D%26sa%3DN; 2005-03-28-11:00.
    • (2005) EE70 Series
  • 7
    • 33745977431 scopus 로고    scopus 로고
    • Quasi-adaptive fuzzy heating control of solar buildings
    • Gouda, G.G., Danaher, S., and Underwood, C.P. (2006) Quasi-adaptive fuzzy heating control of solar buildings. Building and Environment, 41, pp.1881-1891.
    • (2006) Building and Environment , vol.41 , pp. 1881-1891
    • Gouda, G.G.1    Danaher, S.2    Underwood, C.P.3
  • 9
    • 0033879856 scopus 로고    scopus 로고
    • Artificial neural networks for the prediction of the energy consumption of a passive solar building
    • Kalogirou, S.A. and Bojic, M. (2000) Artificial neural networks for the prediction of the energy consumption of a passive solar building. Energy. 25, pp.479-491.
    • (2000) Energy , vol.25 , pp. 479-491
    • Kalogirou, S.A.1    Bojic, M.2
  • 10
    • 80054109430 scopus 로고    scopus 로고
    • Lakewood Engineering, Available from, 2005-11-19-2:30
    • Lakewood Engineering (2005) 2069 ET Radiant Heater. Available from: http://www.lakewoodeng.com/; 2005-11-19-2:30.
    • (2005) 2069 ET Radiant Heater
  • 11
    • 77649235261 scopus 로고    scopus 로고
    • Predictive Control of the Radiant Floor Heating System in Apartment Buildings
    • Lee, J.Y., Yeo, M.S., and Kim, K.W. (2002) Predictive Control of the Radiant Floor Heating System in Apartment Buildings. Journal of Asian Architecture and Building Engineering, 1 (1), pp.105-112.
    • (2002) Journal of Asian Architecture and Building Engineering , vol.1 , Issue.1 , pp. 105-112
    • Lee, J.Y.1    Yeo, M.S.2    Kim, K.W.3
  • 12
    • 77649233065 scopus 로고    scopus 로고
    • LG, Available from, 2008-11-23-5:04
    • LG (2008) DH30 GoldStar Dehumidifier. Available from: http://www.dealtime.com/xPF-LG-LG-Gold-Star-30-Pint-Dehumidifier-DH30-RB; 2008-11-23-5:04.
    • (2008) DH30 GoldStar Dehumidifier
  • 13
    • 84876667530 scopus 로고    scopus 로고
    • MathWorks, Available from, 2008-12-10-17:26
    • MathWorks (2008) MATLAB 14. Available from: http://www.mathworks.com; 2008-12-10-17:26.
    • (2008) MATLAB 14
  • 14
  • 15
    • 77649235003 scopus 로고    scopus 로고
    • Application of ANN (Artificial-Neural-Network) in Residential Thermal Control
    • Building Simulation 2009, University of Strathclyde, Glasgow, July 27-30
    • Moon, J.W., Jung, S.K., and Kim, J.J. (2009) Application of ANN (Artificial-Neural-Network) in Residential Thermal Control. 11TH International Building Performance Simulation Association Conference, Building Simulation 2009, University of Strathclyde, Glasgow, July 27-30, 2009, pp.64-71.
    • (2009) 11TH International Building Performance Simulation Association Conference , vol.2009 , pp. 64-71
    • Moon, J.W.1    Jung, S.K.2    Kim, J.J.3
  • 16
    • 0034961578 scopus 로고    scopus 로고
    • NEUROBAT, a predictive and adaptive heating control system using artificial neural networks
    • Morel, N., Bauer, M., El-Khoury, M., and Krauss, J. (2001) NEUROBAT, a predictive and adaptive heating control system using artificial neural networks. International Journal of Solar Energy, 21, pp.161-201.
    • (2001) International Journal of Solar Energy , vol.21 , pp. 161-201
    • Morel, N.1    Bauer, M.2    El-Khoury, M.3    Krauss, J.4
  • 17
    • 85038458851 scopus 로고    scopus 로고
    • NIQ, Available from, 2006-12-10-15:07
    • NIQ (2006) EZIO™. Available from: http://www.ezio.com/; 2006-12-10-15:07.
    • (2006) EZIO™
  • 18
    • 77649236523 scopus 로고    scopus 로고
    • OMEGA, Available from, 2007-02-18-12:00
    • OMEGA (2007) HX93A Temp/RH Transmitter. Available from: http://www.newportus.com/products/Envnmntl/HX93A.htm; 2007-02-18-12:00.
    • (2007) HX93A Temp/RH Transmitter
  • 19
    • 80054101544 scopus 로고    scopus 로고
    • VENTA SONIC, Available from, 2009-05-18-17:03
    • VENTA SONIC (2009) VS100 Cool and Warm Ultrasonic Humidifier. Available from: http://www.digitalfotoclub.com/sc/from-froogle.asp?id=964702410&rf=froogle&dfdate=5_18_2009; 2009-05-18-17:03.
    • (2009) VS100 Cool and Warm Ultrasonic Humidifier
  • 20
    • 77649238032 scopus 로고    scopus 로고
    • Development of Artificial Neural Network Model for the Prediction of Descending Time of Room Air Temperature
    • Yang, I.H. and Kim, K.W. (2000) Development of Artificial Neural Network Model for the Prediction of Descending Time of Room Air Temperature. International Journal of Air-Conditioning and Refrigeration, 12 (11).
    • (2000) International Journal of Air-Conditioning and Refrigeration , vol.12 , Issue.11
    • Yang, I.H.1    Kim, K.W.2
  • 21
    • 0038238083 scopus 로고    scopus 로고
    • Application of artificial neural network to predict the optimal start time for heating systems in building
    • Yang, I.H., Yeo, M.S., and Kim, K.W. (2003) Application of artificial neural network to predict the optimal start time for heating systems in building. Energy Conversion and Management, 44, pp.2791-2809.
    • (2003) Energy Conversion and Management , vol.44 , pp. 2791-2809
    • Yang, I.H.1    Yeo, M.S.2    Kim, K.W.3
  • 22
    • 25844500264 scopus 로고    scopus 로고
    • On-line building energy prediction using adaptive artificial neural networks
    • Yang, J., Rivard, H., and Zmeureanu, R. (2005) On-line building energy prediction using adaptive artificial neural networks. Energy and Buildings, 37, pp.1250-1259.
    • (2005) Energy and Buildings , vol.37 , pp. 1250-1259
    • Yang, J.1    Rivard, H.2    Zmeureanu, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.