Enhanced dosimetry procedures and assessment for EBT2 radiochromic film

Author keywords

external beam therapy; film dosimetry; gamma analysis; radiochromicfilm; tissue heterogeneity

Indexed keywords

DOSIMETRY; IMAGE ENHANCEMENT; PROCESSING;

EID: 84861594721     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.3694100     Document Type: Article
Times cited : (77)

References (22)
  • 1
    • 0001326870 scopus 로고
    • Sensitometry of the response of a new radiochromic film dosimeter to gamma radiation and electron beams
    • 10.1016/0168-9002(91)90506-L
    • W. L. MacLaughlin Sensitometry of the response of a new radiochromic film dosimeter to gamma radiation and electron beams., Nucl. Instrum. Methods Phys. Res. A 302, 165-117 (1991). 10.1016/0168-9002(91)90506-L
    • (1991) Nucl. Instrum. Methods Phys. Res. A , vol.302 , pp. 165-117
    • MacLaughlin, W.L.1
  • 2
    • 84861624555 scopus 로고    scopus 로고
    • International Specialty Products, Gafchromic EBT2 self-developing film for radiotherapy, ISP White Paper, October
    • International Specialty Products, GAFchromic EBT2 Dosimetry Film Manual, Gafchromic EBT2 self-developing film for radiotherapy, ISP White Paper, October, 2010.
    • (2010) GAFchromic EBT2 Dosimetry Film Manual
  • 3
    • 35649019280 scopus 로고    scopus 로고
    • High sensitivity radiochromic film dosimetry using an optical common-mode rejection and a reflective-mode flatbed color scanner
    • DOI 10.1118/1.2795828
    • H. Ohuchia High sensitivity radiochromic film dosimetry using an optical common-mode rejection and a reflective-mode flatbed color scanner., Med. Phys. 34, 4207-4212 (2007). 10.1118/1.2795828 (Pubitemid 350030821)
    • (2007) Medical Physics , vol.34 , Issue.11 , pp. 4207-4212
    • Ohuchi, H.1
  • 4
    • 84861643858 scopus 로고    scopus 로고
    • SU-GGT275: On improving the accuracy of EBT2 film dosimetry using a flatbed scanner
    • G, 10.1118/1.3468667
    • T. Pawlicki and G. Kim G, SU-GGT275: On improving the accuracy of EBT2 film dosimetry using a flatbed scanner., Med. Phys. 37, 3248-3249 (2010). 10.1118/1.3468667
    • (2010) Med. Phys. , vol.37 , pp. 3248-3249
    • Pawlicki, T.1    Kim, G.2
  • 5
    • 80051700455 scopus 로고    scopus 로고
    • Evaluation of Gafchromic EBT2 dosimetry system for radiotherapy quality assurance
    • 10.1007/s13246-011-0072-6
    • T. Alami, T. Kairn, and J. Kenny Evaluation of Gafchromic EBT2 dosimetry system for radiotherapy quality assurance., Australas. Phys. Eng. Sci. Med. 34, 251-260 (2011). 10.1007/s13246-011-0072-6
    • (2011) Australas. Phys. Eng. Sci. Med. , vol.34 , pp. 251-260
    • Alami, T.1    Kairn, T.2    Kenny, J.3
  • 6
    • 78650102411 scopus 로고    scopus 로고
    • A comprehensive study of the Gafchromic EBT2 radiographic film. A comparison with EBT
    • 10.1118/1.3512792
    • C. Andres, A comprehensive study of the Gafchromic EBT2 radiographic film. A comparison with EBT., Med. Phys. 37, 6271-6278 (2010). 10.1118/1.3512792
    • (2010) Med. Phys. , vol.37 , pp. 6271-6278
    • Andres, C.1
  • 7
    • 80053577338 scopus 로고    scopus 로고
    • Characterizing the marker-dye correction for Gafchromic EBT2 film: A comparison of three analysis methods
    • 10.1118/1.3639997
    • T. McCaw, J. Micka, and L. A. DeWerd Characterizing the marker-dye correction for Gafchromic EBT2 film: A comparison of three analysis methods., Med. Phys. 38, 5771-5777 (2011). 10.1118/1.3639997
    • (2011) Med. Phys. , vol.38 , pp. 5771-5777
    • McCaw, T.1    Micka, J.2    Dewerd, L.A.3
  • 8
    • 59249097881 scopus 로고    scopus 로고
    • Optimizing the dynamic range extension of a radiochromic film dosimetry system
    • 10.1118/1.3049597
    • S. Devic, N. Tomic, C. Soares, and E. Podgorsak, Optimizing the dynamic range extension of a radiochromic film dosimetry system., Med. Phys. 36 (2), 429-437 (2009). 10.1118/1.3049597
    • (2009) Med. Phys. , vol.36 , Issue.2 , pp. 429-437
    • Devic, S.1    Tomic, N.2    Soares, C.3    Podgorsak, E.4
  • 9
    • 78049427805 scopus 로고    scopus 로고
    • Local heterogeneities in early batches of EBT2 film: A suggested solution
    • 10.1088/0031-9155/55/15/L02
    • T. Kairn, T. Aland, and J. Kenny, Local heterogeneities in early batches of EBT2 film: A suggested solution., Phys. Med. Biol. 55, L37-L42 (2010). 10.1088/0031-9155/55/15/L02
    • (2010) Phys. Med. Biol. , vol.55
    • Kairn, T.1    Aland, T.2    Kenny, J.3
  • 10
    • 77951152389 scopus 로고    scopus 로고
    • Evaluation and optimization of the new EBT2 radiochromic film dosimetry system
    • 10.1088/0031-9155/55/9/012
    • L Richley, Evaluation and optimization of the new EBT2 radiochromic film dosimetry system. Phys. Med. Biol. 55, 2601-2617 (2010). 10.1088/0031-9155/55/9/ 012
    • (2010) Phys. Med. Biol. , vol.55 , pp. 2601-2617
    • Richley, L.1
  • 11
    • 77950551727 scopus 로고    scopus 로고
    • Technical note: Homogeneity of Gafchromic EBT2 film
    • 10.1118/1.3368601
    • B. Hartmann, Technical note: Homogeneity of Gafchromic EBT2 film., Med. Phys. 37, 1753-1756 (2010). 10.1118/1.3368601
    • (2010) Med. Phys. , vol.37 , pp. 1753-1756
    • Hartmann, B.1
  • 15
    • 46149099592 scopus 로고    scopus 로고
    • Radiochromic film dosimetry with flatbed scanners: A fast and accurate method for dose calibration and uniformity correction with single film exposure
    • DOI 10.1118/1.2936334
    • L. Menegotti, Radiochromic film dosimetry with flatbed scanners: A fast and accurate method for dose calibration and uniformity correction with single film exposure., Med. Phys. 35, 3078-3085 (2008). 10.1118/1.2936334 (Pubitemid 351904511)
    • (2008) Medical Physics , vol.35 , Issue.7 , pp. 3078-3085
    • Menegotti, L.1    Delana, A.2    Martignano, A.3
  • 16
    • 33750564064 scopus 로고    scopus 로고
    • Sensitivity of linear CCD array based film scanners used for film dosimetry
    • DOI 10.1118/1.2357836
    • S. Devic, Sensitivity of linear CCD array based film scanners used for film dosimetry., Med. Phys. 33, 3993-3996 (2006). 10.1118/1.2357836 (Pubitemid 44673090)
    • (2006) Medical Physics , vol.33 , Issue.11 , pp. 3993-3996
    • Devic, S.1    Wang, Y.-Z.2    Tomic, N.3    Podgorsak, E.B.4
  • 18
    • 46149100990 scopus 로고    scopus 로고
    • GafChromic EBT film dosimetry with flatbed CCD scanner: A novel background correction method and full dose uncertainty analysis
    • DOI 10.1118/1.2938522
    • S Saur and J Frengen, Gafchromic EBT film dosimetry with flatbed CCD scanner: A novel background correction method and full dose uncertainty analysis., Med. Phys. 35, 3094-3101 (2008). 10.1118/1.2938522 (Pubitemid 351904513)
    • (2008) Medical Physics , vol.35 , Issue.7 , pp. 3094-3101
    • Saur, S.1    Frengen, J.2
  • 19
    • 79959573017 scopus 로고    scopus 로고
    • Multichannel film dosimetry with nonuniformity correction
    • Lewis, and, 10.1118/1.3576105
    • A Micke, D. F Lewis, and X. Yu, Multichannel film dosimetry with nonuniformity correction., Med. Phys. 38, 2523-2534 (2011). 10.1118/1.3576105
    • (2011) Med. Phys. , vol.38 , pp. 2523-2534
    • Micke, A.1    Lewis, D.F.2    Yu, X.3
  • 20
    • 0031861573 scopus 로고    scopus 로고
    • A technique for the quantitative evaluation of dose distributions
    • DOI 10.1118/1.598248
    • D. A. Low, A technique for the quantitative evaluation of dose distributions., Med. Phys. 25, 656-661 (1998). 10.1118/1.598248 (Pubitemid 28234885)
    • (1998) Medical Physics , vol.25 , Issue.5 , pp. 656-661
    • Low, D.A.1    Harms, W.B.2    Mutic, S.3    Purdy, J.A.4
  • 21
    • 0036227283 scopus 로고    scopus 로고
    • A quantitative evaluation of IMRT dose distributions: Refinement and clinical assessment of the gamma evaluation
    • DOI 10.1016/S0167-8140(01)00497-2, PII S0167814001004972
    • T. Depuydt, A. Van Esch, and D. P. Huyskens, A quantitative evaluation of IMRT dose distributions: Refinement and clinical assessment of the gamma evaluation., Radiother. Oncol. 62, 309-319 (2002). 10.1016/S0167-8140(01)00497-2 (Pubitemid 34304194)
    • (2002) Radiotherapy and Oncology , vol.62 , Issue.3 , pp. 309-319
    • Depuydt, T.1    Van Esch, A.2    Huyskens, D.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.