-
1
-
-
33750724124
-
Outcome after closed functional treatment of humeral shaft fractures
-
DOI 10.1097/01.bot.0000246466.01287.04, PII 0000513120061000000001
-
Ekholm R, Tidermark J, Törnkvist H, Adami J, Ponzer S (2006) Outcome after closed functional treatment of humeral shaft fractures. J Orthop Trauma 20:591-596 (Pubitemid 44706898)
-
(2006)
Journal of Orthopaedic Trauma
, vol.20
, Issue.9
, pp. 591-596
-
-
Ekholm, R.1
Tidermark, J.2
Tornkvist, H.3
Adami, J.4
Ponzer, S.5
-
2
-
-
13844269288
-
Functional treatment of closed humeral shaft fractures
-
DOI 10.1007/s00264-004-0612-8
-
Toivanen JA, Nieminen J, Laine HJ, Honkonen SE, Järvinen MJ (2005) Functional treatment of closed humeral shaft fractures. Int Orthop 29:10-13 (Pubitemid 40248282)
-
(2005)
International Orthopaedics
, vol.29
, Issue.1
, pp. 10-13
-
-
Toivanen, J.A.K.1
Nieminen, J.2
Laine, H.-J.3
Honkonen, S.E.4
Jarvinen, M.J.5
-
3
-
-
77955690197
-
Fractures of the humeral shaft
-
Browner BD, Jupiter JB,Levine AM, Trafton PG (eds)., 3rd edn. WB Saunders Company
-
Schemitsch EH, Bhandari M (2003) Fractures of the humeral shaft. In: Browner BD, Jupiter JB,Levine AM, Trafton PG (eds). Skeletal trauma: basic science, management and reconstruction, 3rd edn. WB Saunders Company, pp 1487-1488
-
(2003)
Skeletal Trauma: Basic Science, Management and Reconstruction
, pp. 1487-1488
-
-
Schemitsch, E.H.1
Bhandari, M.2
-
4
-
-
2342641983
-
Plating of humeral shaft fractures - Has the pendulum swung back?
-
DOI 10.1016/j.injury.2003.10.021, PII S0020138303004650
-
Niall DM, O'Mahony J, McElwain JP (2004) Plating of humeral shaft fractures-has the pendulum swung back? Injury 35:580-586 (Pubitemid 38595393)
-
(2004)
Injury
, vol.35
, Issue.6
, pp. 580-586
-
-
Niall, D.M.1
O'Mahony, J.2
McElwain, J.P.3
-
5
-
-
34249061825
-
Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus. A randomised controlled study
-
DOI 10.1007/s00264-006-0200-1
-
Changulani M, Jain UK, Keswani T (2007) Comparison of the use of the humerus intramedullary nail and dynamic compression plate for the management of diaphyseal fractures of the humerus. A randomised controlled study. Int Orthop 31:391-395 (Pubitemid 46800766)
-
(2007)
International Orthopaedics
, vol.31
, Issue.3
, pp. 391-395
-
-
Changulani, M.1
Jain, U.K.2
Keswani, T.3
-
6
-
-
1242270571
-
Five years' clinical experience with the unreamed humeral nail in the treatment of humeral shaft fractures
-
DOI 10.1016/S0020-1383(03)00220-1
-
Fernandez FF, Matschke S, Hülsenbeck A, Egenolf M, Wentzensen A (2004) Five years' clinical experience with the unreamed humeral nail in the treatment of humeral shaft fractures. Injury 35:264-271 (Pubitemid 38221206)
-
(2004)
Injury
, vol.35
, Issue.3
, pp. 264-271
-
-
Fernandez, F.F.1
Matschke, S.2
Hulsenbeck, A.3
Egenolf, M.4
Wentzensen, A.5
-
7
-
-
3042544491
-
Antegrade interlocking nailing of humeral shaft fractures
-
DOI 10.1007/s00776-004-0780-9
-
Petsatodes G, Karataglis D, Papadopoulos P, Christoforides J, Gigis J, Pournaras J (2004) Antegrade interlocking nailing of humeral shaft fractures. J Orthop Sci 9:247-252 (Pubitemid 38802080)
-
(2004)
Journal of Orthopaedic Science
, vol.9
, Issue.3
, pp. 247-252
-
-
Petsatodes, G.1
Karataglis, D.2
Papadopoulos, P.3
Christoforides, J.4
Gigis, J.5
Pournaras, J.6
-
8
-
-
58849107239
-
Functional long-term outcome of the shoulder after antegrade intramedullary nailing in humeral diaphyseal fractures
-
Pogliacomi F, Devecchi A, Costantino C, Vaienti E (2008) Functional long-term outcome of the shoulder after antegrade intramedullary nailing in humeral diaphyseal fractures. Chir Organi Mov 92:11-16
-
(2008)
Chir Organi Mov
, vol.92
, pp. 11-16
-
-
Pogliacomi, F.1
Devecchi, A.2
Costantino, C.3
Vaienti, E.4
-
9
-
-
0000638513
-
Compression plating versus intramedullary fixation of humeral shaft fractures
-
Gregory PR, Sanders RW (1997) Compression plating versus intramedullary fixation of humeral shaft fractures. J Am Acad Orthop Surg 5:215-223
-
(1997)
J Am Acad Orthop Surg
, vol.5
, pp. 215-223
-
-
Gregory, P.R.1
Sanders, R.W.2
-
12
-
-
0038463579
-
Expandable nail system for osteoporotic humeral shaft fractures: Preliminary results
-
Franck WM, Olivieri M, Jannasch O, Hennig FF (2003) Expandable nail system for osteoporotic humeral shaft fractures: preliminary results. J Trauma 54:1152-1158 (Pubitemid 36764888)
-
(2003)
Journal of Trauma - Injury, Infection and Critical Care
, vol.54
, Issue.6
, pp. 1152-1158
-
-
Franck, W.M.1
Olivieri, M.2
Jannasch, O.3
Hennig, F.F.4
-
13
-
-
48249156574
-
The Fixion nailing system for stabilising diaphyseal fractures of the humerus: A two-year clinical experience
-
Mallick E, Hazarika S, Assad S, Scott M (2008) The Fixion nailing system for stabilising diaphyseal fractures of the humerus: a two-year clinical experience. Acta Orthop Belg 74:308-316
-
(2008)
Acta Orthop Belg
, vol.74
, pp. 308-316
-
-
Mallick, E.1
Hazarika, S.2
Assad, S.3
Scott, M.4
-
14
-
-
14744300697
-
Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture: Is it possible? A cadaveric study and preliminary report
-
DOI 10.1016/j.injury.2004.05.036
-
Apivatthakakul T, Arpornchayanon O, Bavornratanavech S (2005) Minimally invasive plate osteosynthesis (MIPO) of the humeral shaft fracture. Is it possible? A cadaveric study and preliminary report. Injury 36:530-538 (Pubitemid 40332338)
-
(2005)
Injury
, vol.36
, Issue.4
, pp. 530-538
-
-
Apivatthakakul, T.1
Arpornchayanon, O.2
Bavornratanavech, S.3
-
15
-
-
35148886200
-
Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures
-
DOI 10.1097/BOT.0b013e31815928c2, PII 0000513120071000000006
-
Zhiquan A, Bingfang Z, Yeming W, Chi Z, Peiyan H (2007) Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures. J Orthop Trauma 21:628-633 (Pubitemid 47549097)
-
(2007)
Journal of Orthopaedic Trauma
, vol.21
, Issue.9
, pp. 628-633
-
-
Zhiquan, A.1
Bingfang, Z.2
Yeming, W.3
Chi, Z.4
Peiyan, H.5
-
16
-
-
77949903328
-
Plating osteosynthesis of mid-distal humeral shaft fractures: Minimally invasive versus conventional open reduction technique
-
An Z, Zeng B, He X, Chen Q, Hu S (2010) Plating osteosynthesis of mid-distal humeral shaft fractures: minimally invasive versus conventional open reduction technique. Int Orthop 34:131-135
-
(2010)
Int Orthop
, vol.34
, pp. 131-135
-
-
An, Z.1
Zeng, B.2
He, X.3
Chen, Q.4
Hu, S.5
-
17
-
-
0012513163
-
Fracture and dislocation compendium
-
Association OrthopaedicTrauma
-
Association OrthopaedicTrauma (1996) Fracture and dislocation compendium. J Orthop Trauma 10(Suppl 1):1-55
-
(1996)
J Orthop Trauma
, vol.10
, Issue.SUPPL. 1
, pp. 1-55
-
-
-
19
-
-
0023543657
-
Arthroscopic subacromial decompression: Analysis of one- to three-year results
-
Ellman H (1987) Arthroscopic subacromial decompression: analysis of 1 to 3 year results. Arthroscopy 3:173-181 (Pubitemid 18049013)
-
(1987)
Arthroscopy
, vol.3
, Issue.3
, pp. 173-181
-
-
Ellman, H.1
-
20
-
-
0000478744
-
The Coonrad-Morrey total elbow arthroplasty in patients who have rheumatoid arthritis: A ten to fifteen-year follow-up study
-
Gill DR, Morrey BF (1998) The Coonrad-Morrey total elbow arthroplasty in patients who have rheumatoid arthritis. A ten to fifteen-year follow-up study. J Bone Joint Surg Am 80:1327-1335 (Pubitemid 28443357)
-
(1998)
Journal of Bone and Joint Surgery - Series A
, vol.80
, Issue.9
, pp. 1327-1335
-
-
Gill, D.R.J.1
Morrey, B.F.2
-
21
-
-
77950273998
-
Early full range of shoulder and elbow motion is possible after minimally invasive plate osteosynthesis for humeral shaft fractures
-
Kobayashi M, Watanabe Y, Matsushita T (2010) Early full range of shoulder and elbow motion is possible after minimally invasive plate osteosynthesis for humeral shaft fractures. J Orthop Trauma 24:212-216
-
(2010)
J Orthop Trauma
, vol.24
, pp. 212-216
-
-
Kobayashi, M.1
Watanabe, Y.2
Matsushita, T.3
-
22
-
-
33645764707
-
Compression plating versus intramedullary nailing of humeral shaft fractures - A meta-analysis
-
Bhandari M, Devereaux PJ, McKee MD, Schemitsch EH (2006) Compression plating versus intramedullary nailing of humeral shaft fractures-a meta-analysis. Acta Orthop 77:279-284
-
(2006)
Acta Orthop
, vol.77
, pp. 279-284
-
-
Bhandari, M.1
Devereaux, P.J.2
McKee, M.D.3
Schemitsch, E.H.4
-
23
-
-
0034207578
-
Closed interlocking nailing of humeral shaft fractures with the Russell- Taylor nail
-
Cox MA, Dolan M, Synnott K, McElwain JP (2000) Closed interlocking nailing of humeral shaft fractures with the Russell- Taylor nail. J Orthop Trauma 14:349-353
-
(2000)
J Orthop Trauma
, vol.14
, pp. 349-353
-
-
Cox, M.A.1
Dolan, M.2
Synnott, K.3
McElwain, J.P.4
-
24
-
-
17644366795
-
Humeral shaft fractures treated by dynamic compression plates, Ender nails and interlocking nails
-
Chao TC, Chou WY, Chung JC, Hsu CJ (2005) Humeral shaft fractures treated by dynamic compression plates, Ender nails and interlocking nails. Int Orthop 29:88-91
-
(2005)
Int Orthop
, vol.29
, pp. 88-91
-
-
Chao, T.C.1
Chou, W.Y.2
Chung, J.C.3
Hsu, C.J.4
|