메뉴 건너뛰기




Volumn 21, Issue 3, 2012, Pages 210-221

A novel robotic tactile mass detector with application in clinical breast examination

Author keywords

Artificial tactile sensing; Clinical breast examination; Finite element method; Robotics; Soft tissue

Indexed keywords

ARTICLE; ARTIFICIAL TACTILE SENSING; BREAST EXAMINATION; BREAST TUMOR; CLINICAL EXAMINATION; COMPRESSION; DIAGNOSTIC ACCURACY; DIAGNOSTIC PROCEDURE; HUMAN; MAMMOGRAPHY; PREDICTIVE VALUE; PRIORITY JOURNAL; ROBOTIC TACTILE MASS DETECTOR; ROBOTICS; SCREENING; SENSITIVITY AND SPECIFICITY; SENSOR; THICKNESS;

EID: 84861511677     PISSN: 13645706     EISSN: 13652931     Source Type: Journal    
DOI: 10.3109/13645706.2011.602087     Document Type: Article
Times cited : (14)

References (29)
  • 1
    • 78650055123 scopus 로고    scopus 로고
    • Advances in medical robotic systems with specific applications in Surgery-A Review
    • Najarian S, Fallahnezhad M, Afshari E. Advances in medical robotic systems with specific applications in Surgery-A Review. J Med Eng Technol. 2011;35:19-13.
    • (2011) J Med Eng Technol. , vol.35 , pp. 19-13
    • Najarian, S.1    Fallahnezhad, M.2    Afshari, E.3
  • 2
    • 0028554939 scopus 로고
    • Tactile sensing and control of robotic manipulation
    • Howe RD. Tactile sensing and control of robotic manipulation. Adv Robot. 1994;8:245-261.
    • (1994) Adv Robot. , vol.8 , pp. 245-261
    • Howe, R.D.1
  • 6
    • 17644381242 scopus 로고    scopus 로고
    • Development of tactile mapping system for the stiffness characterization of tissue slice using novel tactile sensing technology
    • Murayama Y, Constantinou CE, Omata S. Development of tactile mapping system for the stiffness characterization of tissue slice using novel tactile sensing technology. Sensors and Actuators A-Physical. 2005;120:543-549.
    • (2005) Sensors and Actuators A-Physical. , vol.120 , pp. 543-549
    • Murayama, Y.1    Constantinou, C.E.2    Omata, S.3
  • 7
    • 1342304956 scopus 로고    scopus 로고
    • An endoscopic force position grasper with minimum sensors
    • Dargahi J, Najarian S. An endoscopic force position grasper with minimum sensors. Can J Electr Comput Eng. 2003;28: 155-161.
    • (2003) Can J Electr Comput Eng. , vol.28 , pp. 155-161
    • Dargahi, J.1    Najarian, S.2
  • 9
    • 84974718083 scopus 로고    scopus 로고
    • Non-invasive measurement of biomechanical properties of in vivo soft tissues
    • LNCS
    • Han L, Burcher M, Noble JA. Non-invasive measurement of biomechanical properties of in vivo soft tissues. MICCAI 2002 LNCS 2488;2002:208-215.
    • (2002) MICCAI , vol.2488 , Issue.2002 , pp. 208-215
    • Han, L.1    Burcher, M.2    Noble, J.A.3
  • 10
    • 33749678423 scopus 로고    scopus 로고
    • Detecting embedded objects using haptics with applications in artificial palpation of masses
    • Najarian S, Dargahi J, Mirjalili V. Detecting embedded objects using haptics with applications in artificial palpation of masses. Sensors & Materials. 2006;18:215-229.
    • (2006) Sensors & Materials. , vol.18 , pp. 215-229
    • Najarian, S.1    Dargahi, J.2    Mirjalili, V.3
  • 13
    • 0141843461 scopus 로고    scopus 로고
    • The Singapore national breast screening program: Principles and implementation
    • Wang SC. The Singapore national breast screening program: principles and implementation, Ann. Acad. Med. Singapore. 2003;32:466-476.
    • (2003) Ann. Acad. Med. Singapore. , vol.32 , pp. 466-476
    • Wang, S.C.1
  • 14
    • 0003964363 scopus 로고    scopus 로고
    • American Cancer Society
    • American Cancer Society. Cancer Facts& Figures. http://www. cancer.org/downloads/STT/2008CAFFfinalsecured.pdf.2008.
    • Cancer Facts& Figures
  • 15
    • 0005189973 scopus 로고    scopus 로고
    • Finger tracking for breast palpation quantification using color image features
    • Zeng J, Wang Y, Freedman MT, Mum SK. Finger tracking for breast palpation quantification using color image features. SPIE J. of Opt. Eng. 1997;36:3455-3461.
    • (1997) SPIE J. of Opt. Eng. , vol.36 , pp. 3455-3461
    • Zeng, J.1    Wang, Y.2    Freedman, M.T.3    Mum, S.K.4
  • 16
    • 0043259073 scopus 로고    scopus 로고
    • Compatible traction stress sensor for use in high-resolution tactile imaging
    • Kane BJ, Cutkosky MR, Kavacs GT. Compatible traction stress sensor for use in high-resolution tactile imaging. Sensors and Actuators A-Physical. 1996;54:511-516.
    • (1996) Sensors and Actuators A-Physical. , vol.54 , pp. 511-516
    • Kane, B.J.1    Cutkosky, M.R.2    Kavacs, G.T.3
  • 17
    • 0032882641 scopus 로고    scopus 로고
    • Mammographic features of ductal carcinoma in situ (DCIS) present on previous mammography
    • Evans AJ, Wilson ARM, Burrell HC, Ellis IO, Pinder SE. Mammographic features of ductal carcinoma in situ (DCIS) present on previous mammography. Clin Radiol. 1999;54: 644-646.
    • (1999) Clin Radiol. , vol.54 , pp. 644-646
    • Evans, A.J.1    Wilson, A.R.M.2    Burrell, H.C.3    Ellis, I.O.4    Pinder, S.E.5
  • 18
    • 0025806883 scopus 로고
    • Elastography: A quantitative method for imaging the elasticity of biological tissues
    • Ophir J, Espedes I, Ponnekanti H, Yazdi Y, Li X. Elastography: a quantitative method for imaging the elasticity of biological tissues. Ultrason. Imag. 1991;13:111-134.
    • (1991) Ultrason. Imag. , vol.13 , pp. 111-134
    • Ophir, J.1    Espedes, I.2    Ponnekanti, H.3    Yazdi, Y.4    Li, X.5
  • 20
    • 0036755508 scopus 로고    scopus 로고
    • Real-time tissue elasticity imaging using the combined autocorrelation method
    • Shiina T, Nitta N, Ueno E, Bamber JC. Real-time tissue elasticity imaging using the combined autocorrelation method. J. Med. Ultrason. 2002;29:119-128.
    • (2002) J. Med. Ultrason. , vol.29 , pp. 119-128
    • Shiina, T.1    Nitta, N.2    Ueno, E.3    Bamber, J.C.4
  • 21
    • 33744502397 scopus 로고    scopus 로고
    • Cross-Sectional Elasticity Imaging of Arterial Wall by Comparing Measured Change in Thickness with Model Waveform
    • Tang J, Hasegawa H, Kanai H. Cross-Sectional Elasticity Imaging of Arterial Wall by Comparing Measured Change in Thickness with Model Waveform. Jpn J Appl Phys. 2005; 44:4588-4592.
    • (2005) Jpn J Appl Phys. , vol.44 , pp. 4588-4592
    • Tang, J.1    Hasegawa, H.2    Kanai, H.3
  • 24
    • 33749654379 scopus 로고    scopus 로고
    • Human tactile perception as a standard for artificial tactile sensing-a review
    • Dargahi J, Najarian S. Human tactile perception as a standard for artificial tactile sensing-a review. Int J Med Robot. 2004;1: 23-35.
    • (2004) Int J Med Robot. , vol.1 , pp. 23-35
    • Dargahi, J.1    Najarian, S.2
  • 25
    • 20444452839 scopus 로고    scopus 로고
    • Advances in tactile sensors design/manufacturing and its impact on robotics application-a review. Industrial Robot
    • Dargahi J, Najarian S. Advances in tactile sensors design/manufacturing and its impact on robotics application-a review. Industrial Robot: An International Journal. 2005;32: 268-281.
    • (2005) An International Journal. , vol.32 , pp. 268-281
    • Dargahi, J.1    Najarian, S.2
  • 29
    • 77949454810 scopus 로고    scopus 로고
    • Abnormal mass detection in a real breast model: A computational tactile sensing approach
    • DOI: 10.1007/978-3-642-03893-8-33
    • Mojra A, Najarian S, Hosseini SM, Towliat Kashani SM, Panahi F. Abnormal mass detection in a real breast model: a computational tactile sensing approach. IFMBE Proceedings. 2009;25/12:115-118. DOI: 10.1007/978-3-642-03893-8-33.
    • (2009) IFMBE Proceedings. , vol.25 , pp. 115-118
    • Mojra, A.1    Najarian, S.2    Hosseini, S.M.3    Towliat Kashani, S.M.4    Panahi, F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.