Image-guided optimization of the ECG trace in cardiac MRI

Author keywords

Cardiac; ECG; Magnetic resonance; MR; Quality improvement

Indexed keywords

ADULT; ARTICLE; ARTIFACT REDUCTION; CARDIOVASCULAR MAGNETIC RESONANCE; CLINICAL ARTICLE; CONTROLLED STUDY; ELECTROCARDIOGRAM LEAD PLACEMENT; ELECTROCARDIOGRAPHY; ELECTROCARDIOGRAPHY MONITORING; FEMALE; HUMAN; IMAGE QUALITY; MALE; PATIENT POSITIONING; PROCESS OPTIMIZATION; THREE DIMENSIONAL IMAGING;

EID: 84861482575     PISSN: 15695794     EISSN: 15730743     Source Type: Journal    
DOI: 10.1007/s10554-011-9865-7     Document Type: Article
Times cited : (7)

References (7)
  • 1
    • 0021327514 scopus 로고
    • Cardiac imaging using gated magnetic resonance
    • Lanzer P, Botvinick EH, Schiller NB, Crooks LE, Arakawa M, Kaufman L, Davis PL, Herfkens R, Lipton MJ, Higgins CB (1984) Cardiac imaging using gated magnetic resonance. Radiology 150(1):121-127 (Pubitemid 14212290)
    • (1984) Radiology , vol.150 , Issue.1 , pp. 121-127
    • Lanzer, P.1    Botvinick, E.H.2    Schiller, N.B.3
  • 2
    • 0023848727 scopus 로고
    • Monitoring of acutely ill patients during nuclear magnetic resonance imaging: Use of a time-varying filter electrocardiographic gating device to reduce gradient artifacts
    • Rokey R, Wendt R, Johnston D (1988) Monitoring of acutely ill patients during nuclear magnetic resonance imaging: use of a time varying filter electrocardiographic gating device to reduce gradient artifacts. Magn Reson Med 6:240-245 (Pubitemid 18066064)
    • (1988) Magnetic Resonance in Medicine , vol.6 , Issue.2 , pp. 240-245
    • Rokey, R.1    Wendt, R.E.2    Johnston, D.L.3
  • 3
    • 0023684480 scopus 로고
    • Suppression of radiofrequency interference in cardiac gated MRI: A simple design
    • Shetty A (1988) Suppression of radiofrequency interference in cardiac gated MRI: a simple design. Magn ResonMed 1:84-88
    • (1988) Magn ResonMed , vol.1 , pp. 84-88
    • Shetty, A.1
  • 4
    • 0024227392 scopus 로고
    • RF interference suppression in a cardiac synchronization system operating in a high magnetic field NMR imaging system
    • DOI 10.1016/0730-725X(88)90086-0
    • Damji A, Snyder R, Ellinger D, Witkowski F, Allen P (1988) RF Interference suppression in cardiac synchronization system operating in a high magnetic field NMR imaging system. Magn Reson Imaging 6:637-640 (Pubitemid 19024844)
    • (1988) Magnetic Resonance Imaging , vol.6 , Issue.6 , pp. 637-640
    • Damji, A.A.1    Snyder, R.E.2    Ellinger, D.C.3    Witkowski, F.X.4    Allen, P.S.5
  • 5
    • 0032873080 scopus 로고    scopus 로고
    • Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitions
    • DOI 10.1002/(SICI)1522-2594(199908)42:2<361::AID-MRM18>3.0.CO;2-9
    • Fischer S, Wickline S, Lorenz C (1999) Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance applications. Magn Reson Med 47:361-370 (Pubitemid 29364715)
    • (1999) Magnetic Resonance in Medicine , vol.42 , Issue.2 , pp. 361-370
    • Fischer, S.E.1    Wickline, S.A.2    Lorenz, C.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.