-
3
-
-
56249111616
-
A comparison of semi custom and custom foot orthotic devices in high and low arched individuals during walking
-
10.1016/j.clinbiomech.2008.07.008
-
A comparison of semi custom and custom foot orthotic devices in high and low arched individuals during walking. Zifchock RA, Davis I, Clin Biomech 2008 23 1287 1293 10.1016/j.clinbiomech.2008.07.008
-
(2008)
Clin Biomech
, vol.23
, pp. 1287-1293
-
-
Zifchock, R.A.1
Davis, I.2
-
4
-
-
0035704756
-
The use of CAD/CAM technology in prosthetics and orthotics-current clinical models and a view to the future
-
11440264
-
The use of CAD/CAM technology in prosthetics and orthotics-current clinical models and a view to the future. Smith DG, Burgess EM, J Rehabil Res Dev 2001 38 327 334 11440264
-
(2001)
J Rehabil Res Dev
, vol.38
, pp. 327-334
-
-
Smith, D.G.1
Burgess, E.M.2
-
6
-
-
0346639199
-
Rapid manufacturing and rapid tooling with layer manufacture (LM) technologies, state of the art and future perspectives
-
10.1016/S0007-8506(07)60206-6
-
Rapid manufacturing and rapid tooling with layer manufacture (LM) technologies, state of the art and future perspectives. Levy GN, Schindel R, Kruth JP, CIRP-Ann-Manuf Techn 2003 52 589 609 10.1016/S0007-8506(07)60206-6
-
(2003)
CIRP-Ann-Manuf Techn
, vol.52
, pp. 589-609
-
-
Levy, G.N.1
Schindel, R.2
Kruth, J.P.3
-
8
-
-
84988650811
-
RepRap: The replicating rapid prototype - Maximizing customizability by breeding the means of production
-
Singapore: World Scientific Piller FT, Tseng MM
-
RepRap: the replicating rapid prototype-maximizing customizability by breeding the means of production. Sells E, Smith Z, Bailard S, Bowyer A, Olliver V, Handbook of Research in Mass Customization and Personalization Singapore: World Scientific, Piller FT, Tseng MM, 2009 568 580
-
(2009)
Handbook of Research in Mass Customization and Personalization
, pp. 568-580
-
-
Sells, E.1
Smith, Z.2
Bailard, S.3
Bowyer, A.4
Olliver, V.5
-
9
-
-
38349010695
-
Manufacture of passive dynamic ankle-foot orthoses using selective laser sintering
-
18270017
-
Manufacture of passive dynamic ankle-foot orthoses using selective laser sintering. Faustini MC, Neptune RR, Crawford RH, Stanhope SJ, IEEE Trans Biomed Eng 2008 55 784 790 18270017
-
(2008)
IEEE Trans Biomed Eng
, vol.55
, pp. 784-790
-
-
Faustini, M.C.1
Neptune, R.R.2
Crawford, R.H.3
Stanhope, S.J.4
-
10
-
-
78651234434
-
Patient specific ankle-foot orthoses using rapid prototyping
-
10.1186/1743-0003-8-1 21226898
-
Patient specific ankle-foot orthoses using rapid prototyping. Mavroidis C, Ranky RG, Sivak ML, Patritti BL, DiPisa J, Caddle A, Gilhooly K, Govoni L, Sivak S, Lancia M, Drillio R, Bonato P, J Neuroeng Rehabil 2011 8 1 10.1186/1743-0003-8-1 21226898
-
(2011)
J Neuroeng Rehabil
, vol.8
, pp. 1
-
-
Mavroidis, C.1
Ranky, R.G.2
Sivak, M.L.3
Patritti, B.L.4
Dipisa, J.5
Caddle, A.6
Gilhooly, K.7
Govoni, L.8
Sivak, S.9
Lancia, M.10
Drillio, R.11
Bonato, P.12
-
11
-
-
77953785691
-
Mass customisation of foot orthoses for rheumatoid arthritis using selective laser sintering
-
20211798
-
Mass customisation of foot orthoses for rheumatoid arthritis using selective laser sintering. Pallari JHP, Dalgarno KW, Woodburn J, IEEE Trans Biomed Eng 2010 57 1750 1756 20211798
-
(2010)
IEEE Trans Biomed Eng
, vol.57
, pp. 1750-1756
-
-
Pallari, J.H.P.1
Dalgarno, K.W.2
Woodburn, J.3
-
12
-
-
84859467843
-
The specification and evaluation of personalised footwear for additive manufacturing
-
Boca Raton: CRC Press Salvendy G
-
The specification and evaluation of personalised footwear for additive manufacturing. Salles A, Gyi DE, Advances in Human Factors, Ergonomics, and Safety in Manufacturing and Service Industries Boca Raton: CRC Press, Salvendy G, 2010 355 366
-
(2010)
Advances in Human Factors, Ergonomics, and Safety in Manufacturing and Service Industries
, pp. 355-366
-
-
Salles, A.1
Gyi, D.E.2
-
13
-
-
79951489297
-
Dimensional accuracy of ankle-foot orthoses constructed by rapid customization and manufacturing framework
-
10.1682/JRRD.2009.12.0195 21328161
-
Dimensional accuracy of ankle-foot orthoses constructed by rapid customization and manufacturing framework. Schrank ES, Stanhope SJ, J Rehabil Res Dev 2011 48 31 42 10.1682/JRRD.2009.12.0195 21328161
-
(2011)
J Rehabil Res Dev
, vol.48
, pp. 31-42
-
-
Schrank, E.S.1
Stanhope, S.J.2
-
14
-
-
33845796707
-
Correlations between subjective treatment responses and plantar pressure parameters of metatarsal pad treatment in metatarsalgia patients: A prospective study
-
Correlations between subjective treatment responses and plantar pressure parameters of metatarsal pad treatment in metatarsalgia patients: a prospective study. Kang JH, Chen MD, Chen SC, Hsi WL, BMC Musculoskelet Disord 7 95
-
BMC Musculoskelet Disord
, vol.7
, pp. 95
-
-
Kang, J.H.1
Chen, M.D.2
Chen, S.C.3
Hsi, W.L.4
-
15
-
-
79960801002
-
Techniques to measure rigidity of ankle-foot orthoses: A review
-
10.1682/JRRD.2010.10.0193 21674406
-
Techniques to measure rigidity of ankle-foot orthoses: a review. Kobayashi T, Leung AK, Hutchins SW, J Rehabil Res Dev 2011 48 565 576 10.1682/JRRD.2010.10.0193 21674406
-
(2011)
J Rehabil Res Dev
, vol.48
, pp. 565-576
-
-
Kobayashi, T.1
Leung, A.K.2
Hutchins, S.W.3
-
16
-
-
77952884914
-
Repeatability of the Pedar-X® in-shoe measuring system
-
Repeatability of the Pedar-X® in-shoe measuring system. Ramanathan AK, Kiran P, Arnold GP, Wang W, Abboud RJ, Foot Ankle Surg 2011 16 70 73
-
(2011)
Foot Ankle Surg
, vol.16
, pp. 70-73
-
-
Ramanathan, A.K.1
Kiran, P.2
Arnold, G.P.3
Wang, W.4
Abboud, R.J.5
-
17
-
-
0031940056
-
Primary metatarsalgia: The influence of a custom moulded insole and a rockerbar on plantar pressure
-
9604274
-
Primary metatarsalgia: the influence of a custom moulded insole and a rockerbar on plantar pressure. Postema K, Burm PE, Zande ME, Limbeek J, Prosthet Orthot Int 1998 22 35 44 9604274
-
(1998)
Prosthet Orthot Int
, vol.22
, pp. 35-44
-
-
Postema, K.1
Burm, P.E.2
Zande, M.E.3
Limbeek, J.4
-
18
-
-
65249124621
-
Effect of ankle-foot orthosis alignment and foot-plate length on the gait of adults with poststroke hemiplegia
-
10.1016/j.apmr.2008.11.012 19406301
-
Effect of ankle-foot orthosis alignment and foot-plate length on the gait of adults with poststroke hemiplegia. Fatone S, Gard SA, Malas BA, Arch Phys Med Rehabil 2009 90 810 818 10.1016/j.apmr.2008.11.012 19406301
-
(2009)
Arch Phys Med Rehabil
, vol.90
, pp. 810-818
-
-
Fatone, S.1
Gard, S.A.2
Malas, B.A.3
-
19
-
-
21744456749
-
A comparison of gait with solid and hinged ankle-foot orthoses in children with spastic diplegic cerebral palsy
-
10.1016/j.gaitpost.2004.03.004 15760746
-
A comparison of gait with solid and hinged ankle-foot orthoses in children with spastic diplegic cerebral palsy. Radtka SA, Skinner SR, Johanson ME, Gait Posture 2005 21 303 310 10.1016/j.gaitpost.2004.03.004 15760746
-
(2005)
Gait Posture
, vol.21
, pp. 303-310
-
-
Radtka, S.A.1
Skinner, S.R.2
Johanson, M.E.3
-
20
-
-
77956134210
-
Polypropylene ankle foot orthoses to overcome foot-drop gait in central neurological patients: A mechanical and functional evaluation
-
10.3109/03093646.2010.495969 20738233
-
Polypropylene ankle foot orthoses to overcome foot-drop gait in central neurological patients: a mechanical and functional evaluation. Bregman DJ, De Groot V, Van Diggele P, Meulman H, Houjik H, Harlaar J, Prosthet Orthot Int 2010 34 293 304 10.3109/03093646.2010.495969 20738233
-
(2010)
Prosthet Orthot Int
, vol.34
, pp. 293-304
-
-
Bregman, D.J.1
De Groot, V.2
Van Diggele, P.3
Meulman, H.4
Houjik, H.5
Harlaar, J.6
-
21
-
-
67649385562
-
A new method for evaluating ankle foot orthosis characteristics: BRUCE
-
10.1016/j.gaitpost.2009.05.012 19520576
-
A new method for evaluating ankle foot orthosis characteristics: BRUCE. Bregman DJ, Rozumalski A, Koops D, De Groot V, Schwartz M, Harlaar J, Gait Posture 2009 30 144 149 10.1016/j.gaitpost.2009.05.012 19520576
-
(2009)
Gait Posture
, vol.30
, pp. 144-149
-
-
Bregman, D.J.1
Rozumalski, A.2
Koops, D.3
De Groot, V.4
Schwartz, M.5
Harlaar, J.6
-
22
-
-
79953732773
-
Foot orthoses: How much customisation is necessary?
-
10.1186/1757-1146-2-23 19589160
-
Foot orthoses: how much customisation is necessary? Menz HB, J Foot Ankle Res 2009 2 23 10.1186/1757-1146-2-23 19589160
-
(2009)
J Foot Ankle Res
, vol.2
, pp. 23
-
-
Menz, H.B.1
-
23
-
-
79953766989
-
The use of 3D surface scanning for the measurement and assessment of the human foot
-
The use of 3D surface scanning for the measurement and assessment of the human foot. Telfer S, Woodburn J, J Foot Ankle Res 2010 5 19
-
(2010)
J Foot Ankle Res
, vol.5
, pp. 19
-
-
Telfer, S.1
Woodburn, J.2
|