메뉴 건너뛰기




Volumn 26, Issue 3, 2012, Pages 206-214

Serum Creatinine Determined by Jaffe, Enzymatic Method, and Isotope Dilution-Liquid Chromatography-Mass Spectrometry in Patients Under Hemodialysis

Author keywords

Creatinine; Enzymatic method; Hemodialysis (HD); Isotope dilution liquid chromatography mass spectrometry (IDLCMS); Jaffe method; Uremia

Indexed keywords

ALBUMIN; CREATININE; GLOBULIN; GLUCOSE; PHOSPHORUS; POTASSIUM;

EID: 84861466015     PISSN: 08878013     EISSN: 10982825     Source Type: Journal    
DOI: 10.1002/jcla.21495     Document Type: Article
Times cited : (42)

References (23)
  • 1
    • 77954645102 scopus 로고    scopus 로고
    • Comparison of four methods for measuring glomerular filtration rate by inulin clearance in healthy individuals and patients with renal failure
    • Ocampo JH, Rosales AT, Castellanos FR. Comparison of four methods for measuring glomerular filtration rate by inulin clearance in healthy individuals and patients with renal failure. Nefrologia 2010;30:324-330.
    • (2010) Nefrologia , vol.30 , pp. 324-330
    • Ocampo, J.H.1    Rosales, A.T.2    Castellanos, F.R.3
  • 2
    • 34147144578 scopus 로고    scopus 로고
    • Glomerular filtration rate measurement and estimation in chronic kidney disease
    • Schwartz GJ, Furth SL. Glomerular filtration rate measurement and estimation in chronic kidney disease. Pediatr Nephrol 2007;22:1839-1848.
    • (2007) Pediatr Nephrol , vol.22 , pp. 1839-1848
    • Schwartz, G.J.1    Furth, S.L.2
  • 3
    • 0018472223 scopus 로고
    • Use of serum creatinine concentrations to determine renal function
    • Bjornsson TD. Use of serum creatinine concentrations to determine renal function. Clin Pharmacokinet 1979;4:200-222.
    • (1979) Clin Pharmacokinet , vol.4 , pp. 200-222
    • Bjornsson, T.D.1
  • 4
    • 0025893319 scopus 로고
    • Interferences in current methods for measurements of creatinine
    • Weber JA, Vanzanten AP. Interferences in current methods for measurements of creatinine. Clin Chem 1991;37:695-700.
    • (1991) Clin Chem , vol.37 , pp. 695-700
    • Weber, J.A.1    Vanzanten, A.P.2
  • 6
    • 84861462635 scopus 로고    scopus 로고
    • Automatisation and interference testing of a new creatinine assay using recombinant creatinine deiminase
    • Gottschalk EM, Holdt-Lehmann B, Bastian M, Schmitz RA, Schuff-Werner P. Automatisation and interference testing of a new creatinine assay using recombinant creatinine deiminase. Clin Chem 2004;50:A27-A27.
    • (2004) Clin Chem , vol.50
    • Gottschalk, E.M.1    Holdt-Lehmann, B.2    Bastian, M.3    Schmitz, R.A.4    Schuff-Werner, P.5
  • 7
    • 77956875677 scopus 로고    scopus 로고
    • GC-MS determination of creatinine in human biological fluids as pentafluorobenzyl derivative in clinical studies and biomonitoring: Inter-laboratory comparison in urine with Jaffe, HPLC and enzymatic assays
    • Tsikas D, Wolf A, Mitschke A, Gutzki F-M, Will W, Bader M. GC-MS determination of creatinine in human biological fluids as pentafluorobenzyl derivative in clinical studies and biomonitoring: Inter-laboratory comparison in urine with Jaffe, HPLC and enzymatic assays. J Chromatogr B 2010;878:2582-2592.
    • (2010) J Chromatogr B , vol.878 , pp. 2582-2592
    • Tsikas, D.1    Wolf, A.2    Mitschke, A.3    Gutzki, F.-M.4    Will, W.5    Bader, M.6
  • 8
    • 0024384438 scopus 로고
    • Nitromethane interferes in assay of creatinine by the jaffe reaction
    • Deleacy EA, Brown NN, Clague AE. Nitromethane interferes in assay of creatinine by the jaffe reaction. Clin Chem 1989;35:1772-1774.
    • (1989) Clin Chem , vol.35 , pp. 1772-1774
    • Deleacy, E.A.1    Brown, N.N.2    Clague, A.E.3
  • 9
    • 0032824087 scopus 로고    scopus 로고
    • Elevated creatinine after ingestion of model aviation fuel: Interference with the Jaffe reaction by nitromethane
    • Booth CJ, Naidoo D, Rosenberg AR, Kainer G. Elevated creatinine after ingestion of model aviation fuel: Interference with the Jaffe reaction by nitromethane. J Paediatr Child Health 1999;35:503-504.
    • (1999) J Paediatr Child Health , vol.35 , pp. 503-504
    • Booth, C.J.1    Naidoo, D.2    Rosenberg, A.R.3    Kainer, G.4
  • 10
    • 0024245501 scopus 로고
    • Lactulose interferes in the alkaline picrate assay for creatinine
    • Bruns DE. Lactulose interferes in the alkaline picrate assay for creatinine. Clin Chem 1988;34:2592-2593.
    • (1988) Clin Chem , vol.34 , pp. 2592-2593
    • Bruns, D.E.1
  • 11
    • 0021361924 scopus 로고
    • The effect of neonatal hyperbilirubinemia on the measurement of plasma creatinine
    • Feld LG, Langford DJ, Schwartz GJ. The effect of neonatal hyperbilirubinemia on the measurement of plasma creatinine. Clini Pediatr 1984;23:154-156.
    • (1984) Clini Pediatr , vol.23 , pp. 154-156
    • Feld, L.G.1    Langford, D.J.2    Schwartz, G.J.3
  • 12
    • 0025983920 scopus 로고
    • HPLC with enzymatic detection as a candidate reference method for serum creatinine
    • Linnet K, Bruunshuus I. HPLC with enzymatic detection as a candidate reference method for serum creatinine. Clin Chem 1991;37:1669-1675.
    • (1991) Clin Chem , vol.37 , pp. 1669-1675
    • Linnet, K.1    Bruunshuus, I.2
  • 13
    • 0025218782 scopus 로고
    • An improved cation exchange HPLC method for the measurement of serum creatinine
    • Guy JM, Legg EF. An improved cation exchange HPLC method for the measurement of serum creatinine. Ann Clin Biochem 1990;27(Pt 3):223-226.
    • (1990) Ann Clin Biochem , vol.27 , Issue.PART 3 , pp. 223-226
    • Guy, J.M.1    Legg, E.F.2
  • 17
    • 77957934056 scopus 로고    scopus 로고
    • Metabolomic search for uremic toxins as indicators of the effect of an oral sorbent AST-120 by liquid chromatography/tandem mass spectrometry
    • Kikuchi K, Itoh Y, Tateoka R, Ezawa A, Murakami K, Niwa T Metabolomic search for uremic toxins as indicators of the effect of an oral sorbent AST-120 by liquid chromatography/tandem mass spectrometry. J Chromatogr B 2010;878:2997-3002.
    • (2010) J Chromatogr B , vol.878 , pp. 2997-3002
    • Kikuchi, K.1    Itoh, Y.2    Tateoka, R.3    Ezawa, A.4    Murakami, K.5    Niwa, T.6
  • 18
    • 33644696674 scopus 로고    scopus 로고
    • Validation of a liquid chromatography tandem mass spectrometry assay for serum creatinine and comparison with enzymatic and Jaffe methods
    • Owen LJ, Wear JE, Keevil BG. Validation of a liquid chromatography tandem mass spectrometry assay for serum creatinine and comparison with enzymatic and Jaffe methods. Ann Clin Biochem 2006;43:118-123.
    • (2006) Ann Clin Biochem , vol.43 , pp. 118-123
    • Owen, L.J.1    Wear, J.E.2    Keevil, B.G.3
  • 21
    • 36349006181 scopus 로고    scopus 로고
    • Measurement of serum creatinine-current status and future goals
    • Peake M, Whiting M. Measurement of serum creatinine-current status and future goals. Clin Biochem Rev 2006;27:173-184.
    • (2006) Clin Biochem Rev , vol.27 , pp. 173-184
    • Peake, M.1    Whiting, M.2
  • 22
    • 77953516542 scopus 로고    scopus 로고
    • Exogenous interferences with Jaffe creatinine assays: Addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methods
    • Srisawasdi P, Chaichanajarernkul U, Teerakanjana N, Vanavanan A, Kroll MH. Exogenous interferences with Jaffe creatinine assays: Addition of sodium dodecyl sulfate to reagent eliminates bilirubin and total protein interference with Jaffe methods. J Clin Lab Anal 2010;24:123-133.
    • (2010) J Clin Lab Anal , vol.24 , pp. 123-133
    • Srisawasdi, P.1    Chaichanajarernkul, U.2    Teerakanjana, N.3    Vanavanan, A.4    Kroll, M.H.5
  • 23
    • 77956173033 scopus 로고    scopus 로고
    • Development and validation of a rapid liquid chromatography isotope dilution tandem mass spectrometry (LC-IDMS/MS) method for serum creatinine
    • Hetu PO, Gingras ME, Vinet B. Development and validation of a rapid liquid chromatography isotope dilution tandem mass spectrometry (LC-IDMS/MS) method for serum creatinine. Clin Biochem 2010;43:1158-1162.
    • (2010) Clin Biochem , vol.43 , pp. 1158-1162
    • Hetu, P.O.1    Gingras, M.E.2    Vinet, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.