메뉴 건너뛰기




Volumn 27, Issue 2, 2012, Pages 318-327

Three-phase asymmetric transformer aging considering voltage-current harmonic interactions, unbalanced nonlinear loading, magnetic couplings, and hysteresis

Author keywords

Aging; Arrhenius thermal reaction rate theory; transformer and power quality; weighted harmonic factor (WHF)

Indexed keywords

AGING EFFECTS; ARRHENIUS; CALCULATION METHODS; CURRENT VOLTAGE; ESTIMATION METHODS; HARMONIC INTERACTIONS; HARMONIC LOSS; IRON CORES; MODEL OUTPUTS; MODEL-BASED OPC; NON-LINEARITY; NON-SINUSOIDAL; NONLINEAR LOAD; NONLINEAR LOADING; OPERATING CONDITION; TERMINAL VOLTAGES; THERMAL REACTION RATES; THERMAL REACTIONS; THREE-PHASE TRANSFORMERS; TIME-DOMAIN MODEL; TRANSFORMER CORE; VOLTAGE HARMONICS; WEIGHTED HARMONIC FACTOR (WHF);

EID: 84861421060     PISSN: 08858969     EISSN: None     Source Type: Journal    
DOI: 10.1109/TEC.2011.2181949     Document Type: Article
Times cited : (31)

References (19)
  • 1
    • 84861425603 scopus 로고    scopus 로고
    • The evolution of power transformers: 110 years of power transformer technology. (2011) [Online]. Available
    • The evolution of power transformers: 110 years of power transformer technology. (2011) [Online]. Available: http://www.abbaustralia.com.au/cawp/ db0003db002698/1d5674d769397bc8c12572f40045bd75.aspx.
  • 4
    • 84920547316 scopus 로고
    • Loading transformers by temperature
    • V. M. Montsinger, "Loading transformers by temperature," Trans. Amer. Inst. Electr. Eng., vol. 49, no. 2, pp. 776-790, 1930.
    • (1930) Trans. Amer. Inst. Electr. Eng. , vol.49 , Issue.2 , pp. 776-790
    • Montsinger, V.M.1
  • 5
    • 23944494340 scopus 로고    scopus 로고
    • On the estimation of elapsed life of oil-immersed power transformers
    • DOI 10.1109/TPWRD.2005.848663
    • M. K. Pradhan and T. S. Ramu, "On the estimation of elapsed life of oilimmersed power transformers," IEEE Trans. Power Del., vol. 20, no. 3, pp. 1962-1969, Jul. 2005. (Pubitemid 41194799)
    • (2005) IEEE Transactions on Power Delivery , vol.20 , Issue.3 , pp. 1962-1969
    • Pradhan, M.K.1    Ramu, T.S.2
  • 6
    • 79953229174 scopus 로고    scopus 로고
    • Distribution transformer loss-oflife reduction by increasing penetration of distributed generation
    • Apr
    • S. M. M. Agah and H. A. Abyaneh, "Distribution transformer loss-oflife reduction by increasing penetration of distributed generation," IEEE Trans. Power Del., vol. 26, no. 2, pp. 1128-1136, Apr. 2011.
    • (2011) IEEE Trans. Power Del. , vol.26 , Issue.2 , pp. 1128-1136
    • Agah, S.M.M.1    Abyaneh, H.A.2
  • 7
    • 79551635682 scopus 로고    scopus 로고
    • Aging condition assessment of transformer oil-paper insulation model based on partial discharge analysis
    • Feb
    • R.-j. Liao, L.-j. Yang, J. Li, and S. Grzybowski, "Aging condition assessment of transformer oil-paper insulation model based on partial discharge analysis," IEEE Trans. Dielectr. Electr. Insul., vol. 18, no. 1, pp. 303-311, Feb. 2011.
    • (2011) IEEE Trans. Dielectr. Electr. Insul. , vol.18 , Issue.1 , pp. 303-311
    • Liao, R.-J.1    Yang, L.-J.2    Li, J.3    Grzybowski, S.4
  • 8
    • 0028465075 scopus 로고
    • Thermal considerations in specifying dry-type transformers
    • Jul./Aug
    • L. W. Pierce, "Thermal considerations in specifying dry-type transformers," IEEE Trans. Ind. Appl., vol. 30, no. 4, pp. 1090-1098, Jul./Aug. 1994.
    • (1994) IEEE Trans. Ind. Appl. , vol.30 , Issue.4 , pp. 1090-1098
    • Pierce, L.W.1
  • 9
    • 0022752593 scopus 로고
    • Aging of electrical appliances due to harmonics of the power system's voltage
    • E. F. Fuchs,D. J.Roesler, and K. P.Kovacs, "Aging of electrical appliances due to harmonics of the power system's voltage," IEEE Trans. Power Del., vol. 1, no. 3, pp. 301-307, Jul. 1986. (Pubitemid 16629661)
    • (1986) IEEE Transactions on Power Delivery , vol.PWRD-1 , Issue.3 , pp. 301-307
    • Fuchs, E.F.1    Roesler, D.J.2    Kovacs, K.P.3
  • 10
    • 0023327407 scopus 로고
    • Sensitivity of electrical appliances to harmonics and fractional harmonics of the power system's voltage - I: Transformers and induction machines
    • E. F. Fuchs, D. J. Roesler, and F. S. Alashhab, "Sensitivity of electrical appliances to harmonics and fractional harmonics of the power system's voltage-Part I: Transformers and induction machines," IEEE Trans. Power Del., vol. 2, no. 2, pp. 437-444, Apr. 1987. (Pubitemid 17565833)
    • (1987) IEEE Transactions on Power Delivery , vol.PWRD-2 , Issue.2 , pp. 437-444
    • Fuchs, E.F.1    Roesler, D.J.2    Alashhab, F.S.3
  • 11
    • 0023327247 scopus 로고
    • Sensitivity of electrical appliances to harmonics and fractional harmonics of the power system's voltage - II: Television sets, induction watthour meters and universal machines
    • E. F. Fuchs, D. J. Roesler, and K. P. Kovacs, "Sensitivity of electrical appliances to harmonics and fractional harmonics of the power system's voltage-Part II: Television sets, induction watthour meters and universal machines," IEEE Trans. Power Del., vol. 2, no. 2, pp. 445-453, Apr. 1987. (Pubitemid 17565832)
    • (1987) IEEE Transactions on Power Delivery , vol.PWRD-2 , Issue.2 , pp. 445-453
    • Fuchs, E.F.1    Roesler, D.J.2    Kovacs, K.P.3
  • 12
    • 77955765209 scopus 로고    scopus 로고
    • Impact of balanced and unbalanced direct current bias on harmonic distortion generated by asymmetric threephase three-leg transformers
    • Aug
    • M. A. S. Masoum and P. S. Moses, "Impact of balanced and unbalanced direct current bias on harmonic distortion generated by asymmetric threephase three-leg transformers," IET Electr. Power Appl., vol. 4, no. 7, pp. 507-515, Aug. 2010.
    • (2010) IET Electr. Power Appl. , vol.4 , Issue.7 , pp. 507-515
    • Masoum, M.A.S.1    Moses, P.S.2
  • 13
    • 79957438045 scopus 로고    scopus 로고
    • Impacts of hysteresis andmagnetic couplings on the stability domain of ferroresonance in asymmetric three-phase three-leg transformers
    • Jun
    • P. S. Moses, M. A. S. Masoum, and H. A. Toliyat, "Impacts of hysteresis andmagnetic couplings on the stability domain of ferroresonance in asymmetric three-phase three-leg transformers," IEEE Trans. Energy Convers., vol. 26, no. 2, pp. 581-592, Jun. 2011.
    • (2011) IEEE Trans. Energy Convers. , vol.26 , Issue.2 , pp. 581-592
    • Moses, P.S.1    Masoum, M.A.S.2    Toliyat, H.A.3
  • 14
    • 78649980069 scopus 로고    scopus 로고
    • Dynamic modeling of three-phase asymmetric power transformers with magnetic hysteresis: No-load and inrush conditions
    • Dec
    • P. S. Moses, M. A. S. Masoum, and H. A. Toliyat, "Dynamic modeling of three-phase asymmetric power transformers with magnetic hysteresis: No-load and inrush conditions," IEEE Trans. Energy Convers., vol. 25, no. 4, pp. 1040-1047, Dec. 2010.
    • (2010) IEEE Trans. Energy Convers. , vol.25 , Issue.4 , pp. 1040-1047
    • Moses, P.S.1    Masoum, M.A.S.2    Toliyat, H.A.3
  • 15
    • 54049143787 scopus 로고    scopus 로고
    • Derating of asymmetric three-phase transformers serving unbalanced nonlinear loads
    • Oct
    • M. A. S. Masoum, P. Moses, and A. S. Masoum, "Derating of asymmetric three-phase transformers serving unbalanced nonlinear loads," IEEE Trans. Power Del., vol. 23, no. 4, pp. 2033-2041, Oct. 2008.
    • (2008) IEEE Trans. Power Del. , vol.23 , Issue.4 , pp. 2033-2041
    • Masoum, M.A.S.1    Moses, P.2    Masoum, A.S.3
  • 17
    • 80052070344 scopus 로고    scopus 로고
    • Realtime coordination of plug-in electric vehicle charging in smart grids to minimize power losses and improve voltage profile
    • Sep
    • S. Deilami, A. Masoum, P. S. Moses, and M. A. S. Masoum, "Realtime coordination of plug-in electric vehicle charging in smart grids to minimize power losses and improve voltage profile," IEEE Trans. Smart Grid, vol. 2, no. 3, pp. 456-467, Sep. 2011.
    • (2011) IEEE Trans. Smart Grid , vol.2 , Issue.3 , pp. 456-467
    • Deilami, S.1    Masoum, A.2    Moses, P.S.3    Masoum, M.A.S.4
  • 18
    • 79960801241 scopus 로고    scopus 로고
    • Smart load management of plug-in electric vehicles in distribution and residential networks with charging stations for peak shaving and loss minimization considering voltage regulation
    • A. S. Masoum, S. Deilami, P. S. Moses, and M. A. S. Masoum, "Smart load management of plug-in electric vehicles in distribution and residential networks with charging stations for peak shaving and loss minimization considering voltage regulation," IET Generat., Transmiss. Distrib., vol. 5, no. 8, pp. 877-888, 2011.
    • (2011) IET Generat., Transmiss. Distrib. , vol.5 , Issue.8 , pp. 877-888
    • Masoum, A.S.1    Deilami, S.2    Moses, P.S.3    Masoum, M.A.S.4
  • 19
    • 0347968142 scopus 로고    scopus 로고
    • Pspice computer model of a nonlinear three-phase three-legged transformer
    • Jan
    • J. Pedra, L. Sainz, F. Corcoles, R. Lopez, and M. Salichs, "PSPICE computer model of a nonlinear three-phase three-legged transformer," IEEE Trans. Power Del., vol. 19, no. 1, pp. 200-207, Jan. 2004.
    • (2004) IEEE Trans. Power Del. , vol.19 , Issue.1 , pp. 200-207
    • Pedra, J.1    Sainz, L.2    Corcoles, F.3    Lopez, R.4    Salichs, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.