Volumn 730, Issue , 2012, Pages 49-59

Cytochrome c biosensor for determination of trace levels of cyanide and arsenic compounds

Author keywords

Boron doped diamond (BDD); Cytochrome c (cyt c); Diffusion coefficients; Toxicity

Indexed keywords

ANALYTES; ARSENIC TRIOXIDE; BDD ELECTRODES; BORON DOPED DIAMOND; BORON-DOPED DIAMOND ELECTRODES; CHARGE TRANSFER RESISTANCE; CYTOCHROME C; DETECTION LIMITS; DIRECT DETERMINATION; ELECTROCATALYTIC; ELECTROCHEMICAL IMPEDANCE; ELECTROCHEMICAL METHODS; EQUIVALENT ELECTRICAL CIRCUITS; FTIR; IMMOBILISATION; INTERFACIAL KINETIC; OXIDATION STATE; PEAK CURRENTS; PHOSPHATE BUFFERS; PLATINUM ELECTRODES; POTASSIUM CYANIDES; PROTEIN BINDING; PRUSSIAN BLUE; Q BANDS; SORET BANDS; SPHERICAL MORPHOLOGIES; SQUARE WAVE VOLTAMMETRY; SURFACE BOND VIBRATIONS; TRACE LEVEL; UV-VIS SPECTROSCOPY;

EID: 84861343570     PISSN: 00032670     EISSN: 18734324     Source Type: Journal    
DOI: 10.1016/j.aca.2012.02.025     Document Type: Article
Times cited : (53)

References (23)
  • 1
    • 0022063210 scopus 로고
    • Amino acid sequence, haem-iron co-ordination geometry and functional properties of mitochondrial and bacterial c-type cytochromes
    • Senn H., Wüthrich K. Amino acid sequence, haem-iron co-ordination geometry and functional properties of mitochondrial and bacterial c-type cytochromes. Quarterly Reviews of Biophysics 1985, 18:111-134.
    • (1985) Quarterly Reviews of Biophysics , vol.18 , pp. 111-134
    • Senn, H.1    Wüthrich, K.2
  • 3
    • 0037015367 scopus 로고    scopus 로고
    • Redox properties of cytochrome c adsorbed on self-assembled monolayers: a probe for protein conformation and orientation
    • Whitesides G.M., Yang J., Ferrigno R., Xiaoxi Chen Redox properties of cytochrome c adsorbed on self-assembled monolayers: a probe for protein conformation and orientation. American Chemical Society 2002, 18:7009-7015.
    • (2002) American Chemical Society , vol.18 , pp. 7009-7015
    • Whitesides, G.M.1    Yang, J.2    Ferrigno, R.3    Xiaoxi, C.4
  • 5
    • 67651002243 scopus 로고    scopus 로고
    • The application of boron-doped diamond electrodes in amperometric biosensors
    • Zhou Y., Zhi J. The application of boron-doped diamond electrodes in amperometric biosensors. Talanta 2009, 79:1189-1196.
    • (2009) Talanta , vol.79 , pp. 1189-1196
    • Zhou, Y.1    Zhi, J.2
  • 6
    • 42049116938 scopus 로고    scopus 로고
    • 2 on a boron-doped diamond film electrode as an electrochemical nitrite biosensor
    • 2 on a boron-doped diamond film electrode as an electrochemical nitrite biosensor. Biomaterials 2008, 29:2794-2801.
    • (2008) Biomaterials , vol.29 , pp. 2794-2801
    • Geng, R.1    Zhao, G.2    Liu, M.3    Li, M.4
  • 7
    • 21844432147 scopus 로고    scopus 로고
    • Characterization of cyanide binding to cytochrome c oxidase immobilized in electrode-supported lipid bilayer membranes
    • Su L., Kelly J.B., Hawkridge F.M., Rhoten M.C., Baskin S.I. Characterization of cyanide binding to cytochrome c oxidase immobilized in electrode-supported lipid bilayer membranes. Journal of Electroanalytical Chemistry 2005, 581:241-248.
    • (2005) Journal of Electroanalytical Chemistry , vol.581 , pp. 241-248
    • Su, L.1    Kelly, J.B.2    Hawkridge, F.M.3    Rhoten, M.C.4    Baskin, S.I.5
  • 8
    • 67349227472 scopus 로고    scopus 로고
    • A nitrite biosensor based on the immobilization of Cytochrome c on multi-walled carbon nanotubes-PAMAM-chitosan nanocomposite modified glass carbon electrode
    • Chen Q., Ai S., Zhu X., Yin H., Ma Q., Qiu Y. A nitrite biosensor based on the immobilization of Cytochrome c on multi-walled carbon nanotubes-PAMAM-chitosan nanocomposite modified glass carbon electrode. Biosensors and Bioelectronics 2009, 24:2991-2996.
    • (2009) Biosensors and Bioelectronics , vol.24 , pp. 2991-2996
    • Chen, Q.1    Ai, S.2    Zhu, X.3    Yin, H.4    Ma, Q.5    Qiu, Y.6
  • 9
    • 0037017693 scopus 로고    scopus 로고
    • Superoxide sensor based on cytochrome c immobilized on mixed-thiol SAM with a new calibration method
    • Ge B., Lisdat F. Superoxide sensor based on cytochrome c immobilized on mixed-thiol SAM with a new calibration method. Analytica Chimica Acta 2002, 454:53-64.
    • (2002) Analytica Chimica Acta , vol.454 , pp. 53-64
    • Ge, B.1    Lisdat, F.2
  • 11
    • 0037134823 scopus 로고    scopus 로고
    • Heme charge-transfer band III is vibronically coupled to the soret band
    • Stefan Franzen S.E.W.-W., Shreve A.P. Heme charge-transfer band III is vibronically coupled to the soret band. American Chemical Society 2002, 124:7148.
    • (2002) American Chemical Society , vol.124 , pp. 7148
    • Stefan Franzen, S.E.W.-W.1    Shreve, A.P.2
  • 12
    • 0037093975 scopus 로고    scopus 로고
    • Spectroelectrochemical determination of the redox potential of cytochrome c via multiple regression
    • Battistuzzi G., Borsari M., Cowan J.A., Ranieri A., Sola M. Spectroelectrochemical determination of the redox potential of cytochrome c via multiple regression. Chemical Society 2002, 83:5315-5324.
    • (2002) Chemical Society , vol.83 , pp. 5315-5324
    • Battistuzzi, G.1    Borsari, M.2    Cowan, J.A.3    Ranieri, A.4    Sola, M.5
  • 13
    • 44449165525 scopus 로고    scopus 로고
    • Cytochrome c gene and protein expression: developmental regulation, environmental response, and pesticide sensitivity in Aedes aegypti
    • Cytochrome c gene and protein expression: developmental regulation, environmental response, and pesticide sensitivity in Aedes aegypti. Journal of Medical Entomology 2008, 45:401-408.
    • (2008) Journal of Medical Entomology , vol.45 , pp. 401-408
  • 14
    • 0006969621 scopus 로고
    • Absorption spectra and some other properties of cytochrome c and of its compounds with ligands
    • B.W.D.a.K.D.
    • B.W.D.a.K.D. Absorption spectra and some other properties of cytochrome c and of its compounds with ligands. Royal Society 1962, 156:429-458.
    • (1962) Royal Society , vol.156 , pp. 429-458
  • 16
    • 37349022461 scopus 로고    scopus 로고
    • Direct electron transfer of cytochrome c and its biosensor based on gold nanoparticles/room temperature ionic liquid/carbon nanotubes composite film
    • Xiang C., Zou Y., Sun L.-X., Xu F. Direct electron transfer of cytochrome c and its biosensor based on gold nanoparticles/room temperature ionic liquid/carbon nanotubes composite film. Electrochemistry Communications 2008, 10:38-41.
    • (2008) Electrochemistry Communications , vol.10 , pp. 38-41
    • Xiang, C.1    Zou, Y.2    Sun, L.-X.3    Xu, F.4
  • 17
    • 0036157160 scopus 로고    scopus 로고
    • Direct cytochrome c electrochemistry at boron-doped diamond electrodes
    • Marken P.C.A., Asogan F.D. Direct cytochrome c electrochemistry at boron-doped diamond electrodes. Electrochemistry Communications 2002, 4:62-66.
    • (2002) Electrochemistry Communications , vol.4 , pp. 62-66
    • Marken, P.C.A.1    Asogan, F.D.2
  • 19
    • 0024982984 scopus 로고
    • Redox reaction mechanism of cytochrome c at modified gold electrodes
    • Sagara N.K., Sone T., Hinnen A., NikiK C. Redox reaction mechanism of cytochrome c at modified gold electrodes. American Chemical Society 1990, 6:254-262.
    • (1990) American Chemical Society , vol.6 , pp. 254-262
    • Sagara, N.K.1    Sone, T.2    Hinnen, A.3    NikiK, C.4
  • 20
    • 0027939319 scopus 로고
    • Monitoring the activity of glucose oxidase during the cultivation of Aspergillus niger using novel amperometric sensor with 1,1'-dimethylferricinium as a mediator
    • Luong J.H.T., Masson C., Brown R.S., Male K.B., Nguyen A.L. Monitoring the activity of glucose oxidase during the cultivation of Aspergillus niger using novel amperometric sensor with 1,1'-dimethylferricinium as a mediator. Biosensors and Bioelectronics 1994, 9:577-584.
    • (1994) Biosensors and Bioelectronics , vol.9 , pp. 577-584
    • Luong, J.H.T.1    Masson, C.2    Brown, R.S.3    Male, K.B.4    Nguyen, A.L.5
  • 22
    • 84861346381 scopus 로고    scopus 로고
    • The Importance of Linear Dynamic Range for Small Molecule and Targeted Peptide LC-MS/MS Quantitation
    • San Jose, CA, USA
    • J. McNally, The Importance of Linear Dynamic Range for Small Molecule and Targeted Peptide LC-MS/MS Quantitation, Thermo Fisher Scientific, San Jose, CA, USA, 2011.
    • (2011) Thermo Fisher Scientific
    • McNally, J.1
  • 23
    • 81355143655 scopus 로고    scopus 로고
    • The importance of linear dynamic range for small molecule and targeted peptide LC-MS/MS quantitation
    • Koppenaal D.W. The importance of linear dynamic range for small molecule and targeted peptide LC-MS/MS quantitation. Analytical Chemistry 2005, p. 419a.
    • (2005) Analytical Chemistry , pp. 419
    • Koppenaal, D.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.