2
-
-
34147149647
-
Experimentally validated numerical method for the hydrodynamic design of horizontal axis tidal turbines
-
Batten W.M.J., Bahaj A.S., Molland A.F., Chaplin J.R. Experimentally validated numerical method for the hydrodynamic design of horizontal axis tidal turbines. Ocean Engineering 2007, 34(7):1013-1020.
-
(2007)
Ocean Engineering
, vol.34
, Issue.7
, pp. 1013-1020
-
-
Batten, W.M.J.1
Bahaj, A.S.2
Molland, A.F.3
Chaplin, J.R.4
-
3
-
-
33747610968
-
Power-electronic systems for the grid integration of renewable energy sources: a survey
-
Carrasco J.M., Franquelo L.G., Bialasiewicz J.T., Galvan E., Guisado R.C.P., Prats M.A.M., et al. Power-electronic systems for the grid integration of renewable energy sources: a survey. IEEE Transactions on Industrial Electronics 2006, 53(4):1002-1016.
-
(2006)
IEEE Transactions on Industrial Electronics
, vol.53
, Issue.4
, pp. 1002-1016
-
-
Carrasco, J.M.1
Franquelo, L.G.2
Bialasiewicz, J.T.3
Galvan, E.4
Guisado, R.C.P.5
Prats, M.A.M.6
-
4
-
-
51149090621
-
Digital simulation of voltage dip characteristics of wind turbine systems
-
Junyent-Ferre A., Gomis-Bellmunt O., Martinez-Rojas M., Sumper A., Sala M., Mata M. Digital simulation of voltage dip characteristics of wind turbine systems. Electrical power quality and utilisation (EPQU 2007), Barcelona, Spain 2007, 1-6.
-
(2007)
Electrical power quality and utilisation (EPQU 2007), Barcelona, Spain
, pp. 1-6
-
-
Junyent-Ferre, A.1
Gomis-Bellmunt, O.2
Martinez-Rojas, M.3
Sumper, A.4
Sala, M.5
Mata, M.6
-
5
-
-
40249107787
-
Advanced grid requirements for the integration of wind farms into the Spanish transmission system
-
Morales A., Robe X., Sala M., Prats P., Aguerri C., Torres E. Advanced grid requirements for the integration of wind farms into the Spanish transmission system. IET Renewable Power Generation 2008, 2(1):47-59.
-
(2008)
IET Renewable Power Generation
, vol.2
, Issue.1
, pp. 47-59
-
-
Morales, A.1
Robe, X.2
Sala, M.3
Prats, P.4
Aguerri, C.5
Torres, E.6
-
6
-
-
79954567512
-
Fault-ride-through capability of oscillating water column-based wave power generation plants equipped with doubly-fed induction generator and air flow control
-
Alberdi M., Amundarain M., Garrido A.J., Garrido I., Maseda F.J. Fault-ride-through capability of oscillating water column-based wave power generation plants equipped with doubly-fed induction generator and air flow control. IEEE Transactions on Industrial Electronics 2011, 58(5):1501-1517.
-
(2011)
IEEE Transactions on Industrial Electronics
, vol.58
, Issue.5
, pp. 1501-1517
-
-
Alberdi, M.1
Amundarain, M.2
Garrido, A.J.3
Garrido, I.4
Maseda, F.J.5
-
7
-
-
77954314020
-
Application of neural networks and genetic algorithms for sizing of photovoltaic systems
-
Mellit A., Kalogirou S.A., Drif M. Application of neural networks and genetic algorithms for sizing of photovoltaic systems. Renewable Energy 2010, 35(12):2881-2893.
-
(2010)
Renewable Energy
, vol.35
, Issue.12
, pp. 2881-2893
-
-
Mellit, A.1
Kalogirou, S.A.2
Drif, M.3
-
8
-
-
78751497311
-
Application of back propagation neural network to fault diagnosis of direct-drive wind turbine
-
Xueli A., Dongxiang J., Shaohua L. Application of back propagation neural network to fault diagnosis of direct-drive wind turbine. World non-grid-connected wind power and energy conference (WNWEC), Nanjing, China 2010, 1-5.
-
(2010)
World non-grid-connected wind power and energy conference (WNWEC), Nanjing, China
, pp. 1-5
-
-
Xueli, A.1
Dongxiang, J.2
Shaohua, L.3
-
11
-
-
77954815196
-
Wave energy and nearshore hot spots: the case of the SE bay of biscay
-
Iglesias G., Carballo R. Wave energy and nearshore hot spots: the case of the SE bay of biscay. Renewable Energy 2010, 35(11):2490-2500.
-
(2010)
Renewable Energy
, vol.35
, Issue.11
, pp. 2490-2500
-
-
Iglesias, G.1
Carballo, R.2
-
12
-
-
0031062282
-
On the efficiency of wave energy caissons in array
-
Thiruvenkatasamy K., Neelamani S. On the efficiency of wave energy caissons in array. Applied Ocean Research 1997, 19(1):61-72.
-
(1997)
Applied Ocean Research
, vol.19
, Issue.1
, pp. 61-72
-
-
Thiruvenkatasamy, K.1
Neelamani, S.2
-
14
-
-
78650196260
-
Modeling and simulation of wave energy generation plants: output power control
-
Amundarain M., Alberdi M., Garrido A.J., Garrido I. Modeling and simulation of wave energy generation plants: output power control. IEEE Transactions on Industrial Electronics 2011, 58(1):105-117.
-
(2011)
IEEE Transactions on Industrial Electronics
, vol.58
, Issue.1
, pp. 105-117
-
-
Amundarain, M.1
Alberdi, M.2
Garrido, A.J.3
Garrido, I.4
-
15
-
-
46449098516
-
The performance of wells turbine under bi-directional air flow
-
Thakker A., Abdulhadi R. The performance of wells turbine under bi-directional air flow. Renewable Energy 2008, 33(11):2467-2474.
-
(2008)
Renewable Energy
, vol.33
, Issue.11
, pp. 2467-2474
-
-
Thakker, A.1
Abdulhadi, R.2
-
16
-
-
38049085666
-
Accurate numerical simulation of a high solidity wells turbine
-
Torresi M., Camporeale S.M., Strippoli P.D., Pascazio G. Accurate numerical simulation of a high solidity wells turbine. Renewable Energy 2008, 33(4):735-747.
-
(2008)
Renewable Energy
, vol.33
, Issue.4
, pp. 735-747
-
-
Torresi, M.1
Camporeale, S.M.2
Strippoli, P.D.3
Pascazio, G.4
-
17
-
-
20444468891
-
Computational analysis of performance and flow investigation on wells turbine for wave energy conversion
-
Dhanasekaran T.S., Govardhan M. Computational analysis of performance and flow investigation on wells turbine for wave energy conversion. Renewable Energy 2005, 30(14):2129-2147.
-
(2005)
Renewable Energy
, vol.30
, Issue.14
, pp. 2129-2147
-
-
Dhanasekaran, T.S.1
Govardhan, M.2
-
18
-
-
77954311162
-
Wave energy plants: control strategies for avoiding the stalling behaviour in the wells turbine
-
Amundarain M., Alberdi M., Garrido A.J., Garrido I., Maseda J. Wave energy plants: control strategies for avoiding the stalling behaviour in the wells turbine. Renewable Energy 2010, 35:2639-2648.
-
(2010)
Renewable Energy
, vol.35
, pp. 2639-2648
-
-
Amundarain, M.1
Alberdi, M.2
Garrido, A.J.3
Garrido, I.4
Maseda, J.5
-
19
-
-
54149104037
-
A twin unidirectional impulse turbine topology for OWC based wave energy plants
-
Jayashankar V., Anand S., Geetha T., Santhakumar S., Jagadeesh Kumar V., Ravindran M., et al. A twin unidirectional impulse turbine topology for OWC based wave energy plants. Renewable Energy 2009, 34(3):692-698.
-
(2009)
Renewable Energy
, vol.34
, Issue.3
, pp. 692-698
-
-
Jayashankar, V.1
Anand, S.2
Geetha, T.3
Santhakumar, S.4
Jagadeesh Kumar, V.5
Ravindran, M.6
-
20
-
-
70449682581
-
Pico OWC recovery project: recent activities and performance data
-
Neumann F., Brito-Melo A., Didier E., Sarmento A. Pico OWC recovery project: recent activities and performance data. Proceedings of the 7th European wave and tidal energy conference, Porto, Portugal 2007.
-
(2007)
Proceedings of the 7th European wave and tidal energy conference, Porto, Portugal
-
-
Neumann, F.1
Brito-Melo, A.2
Didier, E.3
Sarmento, A.4
-
24
-
-
70349625590
-
Direct virtual torque control for doubly fed induction generator grid connection
-
Arbi J., Ghorbal M.J.B., Slama-Belkhodja I., Charaabi L. Direct virtual torque control for doubly fed induction generator grid connection. IEEE Transactions on Industrial Electronics 2009, 56(10):4163-4173.
-
(2009)
IEEE Transactions on Industrial Electronics
, vol.56
, Issue.10
, pp. 4163-4173
-
-
Arbi, J.1
Ghorbal, M.J.B.2
Slama-Belkhodja, I.3
Charaabi, L.4
-
25
-
-
59649114419
-
Real-time implementation of a STATCOM on a wind farm equipped with doubly fed induction generators
-
Qiao W., Venayagamoorthy G.K., Harley R.G. Real-time implementation of a STATCOM on a wind farm equipped with doubly fed induction generators. IEEE Transactions on Industry Applications 2009, 45(1):98-107.
-
(2009)
IEEE Transactions on Industry Applications
, vol.45
, Issue.1
, pp. 98-107
-
-
Qiao, W.1
Venayagamoorthy, G.K.2
Harley, R.G.3
-
26
-
-
34249826455
-
Two alternative modeling approaches for the evaluation of wind farm active and reactive power performances
-
Tapia G., Tapia A., Ostolaza J.X. Two alternative modeling approaches for the evaluation of wind farm active and reactive power performances. IEEE Transactions on Energy Conversion 2006, 21(4):909-920.
-
(2006)
IEEE Transactions on Energy Conversion
, vol.21
, Issue.4
, pp. 909-920
-
-
Tapia, G.1
Tapia, A.2
Ostolaza, J.X.3
-
27
-
-
60449101280
-
Improved control of DFIG systems during network unbalance using PI-R current Regulators
-
Hu J., He Y., Xu L., Williams B.W. Improved control of DFIG systems during network unbalance using PI-R current Regulators. IEEE Transactions on Industrial Electronics 2009, 56(2):439-451.
-
(2009)
IEEE Transactions on Industrial Electronics
, vol.56
, Issue.2
, pp. 439-451
-
-
Hu, J.1
He, Y.2
Xu, L.3
Williams, B.W.4
-
30
-
-
84863999138
-
-
MathWorks, Neural Network Toolbox
-
MathWorks, Neural Network Toolbox: http://www.mathworks.com/products/neural-network/index.html.
-
-
-
-
31
-
-
84863991302
-
-
EVE, Basque Government's energy agency
-
EVE, Basque Government's energy agency: http://www.eve.es/web/Energias-Renovables/Energia-marina.aspx%3flang%3den-GB.
-
-
-
|