메뉴 건너뛰기




Volumn 413, Issue 15-16, 2012, Pages 1259-1264

Evaluation of a novel, commercially available mass spectrometry kit for newborn screening including succinylacetone without hydrazine

Author keywords

High throughput mass spectrometry; Hydrazine; Newborn screening; Succinylacetone; Tyrosinemia type I

Indexed keywords

ACYLCARNITINE; AMINO ACID; BUTANOL; HYDRAZINE; SUCCINYLACETONE; TYROSINE;

EID: 84861330545     PISSN: 00098981     EISSN: 18733492     Source Type: Journal    
DOI: 10.1016/j.cca.2012.04.007     Document Type: Article
Times cited : (11)

References (18)
  • 2
    • 6344262303 scopus 로고    scopus 로고
    • Newborn screening for hepatorenal tyrosinemia by tandem mass spectrometry: analysis of succinylacetone extracted from dried blood spots
    • Allard P., Grenier A., Korson M.S., Zytkovicz T.H. Newborn screening for hepatorenal tyrosinemia by tandem mass spectrometry: analysis of succinylacetone extracted from dried blood spots. Clin Biochem 2004, 37:1010-1015.
    • (2004) Clin Biochem , vol.37 , pp. 1010-1015
    • Allard, P.1    Grenier, A.2    Korson, M.S.3    Zytkovicz, T.H.4
  • 3
    • 71949086542 scopus 로고    scopus 로고
    • The successful inclusion of succinylacetone as a marker of tyrosinemia type I in Tuscany newborn screening program
    • La Marca G., Malvagia S., Funghini S., et al. The successful inclusion of succinylacetone as a marker of tyrosinemia type I in Tuscany newborn screening program. Rapid Commun Mass Spectrom 2009, 23:3891-3893.
    • (2009) Rapid Commun Mass Spectrom , vol.23 , pp. 3891-3893
    • La Marca, G.1    Malvagia, S.2    Funghini, S.3
  • 4
    • 33644554175 scopus 로고    scopus 로고
    • Newborn screening for hepatorenal tyrosinemia: tandem mass spectrometric quantification of succinylacetone
    • Sander J., Janzen N., Peter M., et al. Newborn screening for hepatorenal tyrosinemia: tandem mass spectrometric quantification of succinylacetone. Clin Chem 2006, 52:482-487.
    • (2006) Clin Chem , vol.52 , pp. 482-487
    • Sander, J.1    Janzen, N.2    Peter, M.3
  • 5
    • 42449118446 scopus 로고    scopus 로고
    • Combined newborn screening for succinylacetone, amino acids, and acylcarnitines in dried blood spots
    • Turgeon C., Magera M.J., Allard P., et al. Combined newborn screening for succinylacetone, amino acids, and acylcarnitines in dried blood spots. Clin Chem 2008, 54:657-664.
    • (2008) Clin Chem , vol.54 , pp. 657-664
    • Turgeon, C.1    Magera, M.J.2    Allard, P.3
  • 6
    • 67651096106 scopus 로고    scopus 로고
    • Improved MS/MS analysis of succinylacetone extracted from dried blood spots when combined with amino acids and acylcarnitine butyl esters
    • Chace D.H., Lim T., Hansen C.R., De Jesus V.R., Hannon W.H. Improved MS/MS analysis of succinylacetone extracted from dried blood spots when combined with amino acids and acylcarnitine butyl esters. Clin Chim Acta 2009, 407:6-9.
    • (2009) Clin Chim Acta , vol.407 , pp. 6-9
    • Chace, D.H.1    Lim, T.2    Hansen, C.R.3    De Jesus, V.R.4    Hannon, W.H.5
  • 7
    • 79955034064 scopus 로고    scopus 로고
    • Improved tandem mass spectrometry (MS/MS) derivatized method for the detection of tyrosinemia type I, amino acids and acylcarnitine disorders using a single extraction process
    • Dhillon K.S., Bhandal A.S., Aznar C.P., Lorey F.W., Neogi P. Improved tandem mass spectrometry (MS/MS) derivatized method for the detection of tyrosinemia type I, amino acids and acylcarnitine disorders using a single extraction process. Clin Chim Acta 2011, 412:873-879.
    • (2011) Clin Chim Acta , vol.412 , pp. 873-879
    • Dhillon, K.S.1    Bhandal, A.S.2    Aznar, C.P.3    Lorey, F.W.4    Neogi, P.5
  • 8
    • 78651394440 scopus 로고    scopus 로고
    • The national Austrian newborn screening program - eight years experience with mass spectrometry. past, present, and future goals
    • Kasper D.C., Ratschmann R., Metz T.F., et al. The national Austrian newborn screening program - eight years experience with mass spectrometry. past, present, and future goals. Wien Klin Wochenschr 2010, 122:607-613.
    • (2010) Wien Klin Wochenschr , vol.122 , pp. 607-613
    • Kasper, D.C.1    Ratschmann, R.2    Metz, T.F.3
  • 9
  • 10
    • 0031871486 scopus 로고    scopus 로고
    • Tyrosinaemia type I and NTBC (2-(2-nitro-4-trifluoromethylbenzoyl)-1,3-cyclohexanedione)
    • Holme E., Lindstedt S. Tyrosinaemia type I and NTBC (2-(2-nitro-4-trifluoromethylbenzoyl)-1,3-cyclohexanedione). J Inherit Metab Dis 1998, 21:507-517.
    • (1998) J Inherit Metab Dis , vol.21 , pp. 507-517
    • Holme, E.1    Lindstedt, S.2
  • 11
    • 40849102507 scopus 로고    scopus 로고
    • NTBC treatment in tyrosinaemia type I: long-term outcome in French patients
    • Masurel-Paulet A., Poggi-Bach J., Rolland M.O., et al. NTBC treatment in tyrosinaemia type I: long-term outcome in French patients. J Inherit Metab Dis 2008, 31:81-87.
    • (2008) J Inherit Metab Dis , vol.31 , pp. 81-87
    • Masurel-Paulet, A.1    Poggi-Bach, J.2    Rolland, M.O.3
  • 12
    • 41149109463 scopus 로고    scopus 로고
    • The inclusion of succinylacetone as marker for tyrosinemia type I in expanded newborn screening programs
    • La Marca G., Malvagia S., Pasquini E., et al. The inclusion of succinylacetone as marker for tyrosinemia type I in expanded newborn screening programs. Rapid Commun Mass Spectrom 2008, 22:812-818.
    • (2008) Rapid Commun Mass Spectrom , vol.22 , pp. 812-818
    • La Marca, G.1    Malvagia, S.2    Pasquini, E.3
  • 13
    • 33646488382 scopus 로고    scopus 로고
    • Quantitative determination of succinylacetone in dried blood spots for newborn screening of tyrosinemia type I
    • Magera M.J., Gunawardena N.D., Hahn S.H., et al. Quantitative determination of succinylacetone in dried blood spots for newborn screening of tyrosinemia type I. Mol Genet Metab 2006, 88:16-21.
    • (2006) Mol Genet Metab , vol.88 , pp. 16-21
    • Magera, M.J.1    Gunawardena, N.D.2    Hahn, S.H.3
  • 14
    • 34548476003 scopus 로고    scopus 로고
    • Reduction of the false-positive rate in newborn screening by implementation of MS/MS-based second-tier tests: the Mayo Clinic experience (2004-2007)
    • Matern D., Tortorelli S., Oglesbee D., Gavrilov D., Rinaldo P. Reduction of the false-positive rate in newborn screening by implementation of MS/MS-based second-tier tests: the Mayo Clinic experience (2004-2007). J Inherit Metab Dis 2007, 30:585-592.
    • (2007) J Inherit Metab Dis , vol.30 , pp. 585-592
    • Matern, D.1    Tortorelli, S.2    Oglesbee, D.3    Gavrilov, D.4    Rinaldo, P.5
  • 15
    • 34648826021 scopus 로고    scopus 로고
    • Tandem mass spectrometric determination of succinylacetone in dried blood spots enables presymptomatic detection in a case of hepatorenal tyrosinaemia
    • Weigel J.F., Janzen N., Pfaffle R.W., Thiery J., Kiess W., Ceglarek U. Tandem mass spectrometric determination of succinylacetone in dried blood spots enables presymptomatic detection in a case of hepatorenal tyrosinaemia. J Inherit Metab Dis 2007, 30:610.
    • (2007) J Inherit Metab Dis , vol.30 , pp. 610
    • Weigel, J.F.1    Janzen, N.2    Pfaffle, R.W.3    Thiery, J.4    Kiess, W.5    Ceglarek, U.6
  • 16
    • 65949099515 scopus 로고    scopus 로고
    • Improved method to determine succinylacetone in dried blood spots for diagnosis of tyrosinemia type 1 using UPLC-MS/MS
    • Al-Dirbashi O.Y., Rashed M.S., Jacob M., et al. Improved method to determine succinylacetone in dried blood spots for diagnosis of tyrosinemia type 1 using UPLC-MS/MS. Biomed Chromatogr 2008, 22:1181-1185.
    • (2008) Biomed Chromatogr , vol.22 , pp. 1181-1185
    • Al-Dirbashi, O.Y.1    Rashed, M.S.2    Jacob, M.3
  • 17
    • 84861333955 scopus 로고    scopus 로고
    • Enhanced interpretation of newborn screening results without analyte cutoff values
    • Marquardt G., Currier R., McHugh D.M. Enhanced interpretation of newborn screening results without analyte cutoff values. Genet Med advance online publication February 16 2012, 10.1038/gim.2012.2.
    • (2012) Genet Med advance online publication
    • Marquardt, G.1    Currier, R.2    McHugh, D.M.3
  • 18
    • 79952194543 scopus 로고    scopus 로고
    • Clinical validation of cutoff target ranges in newborn screening of metabolic disorders by tandem mass spectrometry: a worldwide collaborative project
    • McHugh D.M., Cameron C.A., Abdenur J.E., et al. Clinical validation of cutoff target ranges in newborn screening of metabolic disorders by tandem mass spectrometry: a worldwide collaborative project. Genet Med 2011, 13:230-254.
    • (2011) Genet Med , vol.13 , pp. 230-254
    • McHugh, D.M.1    Cameron, C.A.2    Abdenur, J.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.