메뉴 건너뛰기




Volumn 18, Issue 3, 2012, Pages 261-266

Lung monitoring at the bedside in mechanically ventilated patients

Author keywords

acute respiratory distress syndrome; electrical impedance tomography; end expiratory lung volume; functional residual capacity; ICU; mechanical ventilation; respiratory inductive plethysmography; vibration response imaging

Indexed keywords

ASSISTED VENTILATION; COMPUTER ASSISTED IMPEDANCE TOMOGRAPHY; DIAGNOSTIC IMAGING; FUNCTIONAL RESIDUAL CAPACITY; HUMAN; INTENSIVE CARE UNIT; PATIENT MONITORING; PLETHYSMOGRAPHY; POINT OF CARE TESTING; QUALITATIVE ANALYSIS; QUANTITATIVE ANALYSIS; REVIEW; VIBRATION RESPONSE IMAGING; ARTIFICIAL VENTILATION; IMPEDANCE; LUNG FUNCTION TEST; PHYSIOLOGIC MONITORING; POSITIVE END EXPIRATORY PRESSURE; PROCEDURES; VENTILATOR-INDUCED LUNG INJURY;

EID: 84861229093     PISSN: 10705295     EISSN: 15317072     Source Type: Journal    
DOI: 10.1097/MCC.0b013e3283534a4a     Document Type: Review
Times cited : (22)

References (33)
  • 1
    • 0343893748 scopus 로고    scopus 로고
    • Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome
    • The Acute Respiratory Distress Syndrome Network
    • The Acute Respiratory Distress Syndrome Network. Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl JMed 2000; 342:1301-1308.
    • (2000) N. Engl. J. Med. , vol.342 , pp. 1301-1308
  • 2
    • 3242703034 scopus 로고    scopus 로고
    • Higher versus lower positive endexpiratory pressures in patients with the acute respiratory distress syndrome
    • Brower RG, Lanken PN, MacIntyre N, et al. Higher versus lower positive endexpiratory pressures in patients with the acute respiratory distress syndrome. N Engl J Med 2004; 351:327-336.
    • (2004) N. Engl. J. Med. , vol.351 , pp. 327-336
    • Brower, R.G.1    Lanken, P.N.2    MacIntyre, N.3
  • 3
    • 70350237010 scopus 로고    scopus 로고
    • Meta-analysis: Ventilation strategies and outcomes of the acute respiratory distress syndrome and acute lung injury
    • Putensen C, Theuerkauf N, Zinserling J, et al. Meta-analysis: ventilation strategies and outcomes of the acute respiratory distress syndrome and acute lung injury. Ann Intern Med 2009; 151:566-576.
    • (2009) Ann. Intern. Med. , vol.151 , pp. 566-576
    • Putensen, C.1    Theuerkauf, N.2    Zinserling, J.3
  • 4
    • 77649203752 scopus 로고    scopus 로고
    • Higher vs lower positive end-expiratory pressure in patients with acute lung injury and acute respiratory distress syndrome: systematic review and meta-analysis
    • Briel M, Meade M, Mercat A, et al. Higher vs lower positive end-expiratory pressure in patients with acute lung injury and acute respiratory distress syndrome: systematic review and meta-analysis. JAMA 2010; 303:865-873.
    • (2010) JAMA , vol.303 , pp. 865-873
    • Briel, M.1    Meade, M.2    Mercat, A.3
  • 5
    • 44449172104 scopus 로고    scopus 로고
    • Anatomical and functional intrapulmonary shunt in acute respiratory distress syndrome
    • Cressoni M, Caironi P, Polli F, et al. Anatomical and functional intrapulmonary shunt in acute respiratory distress syndrome. Crit Care Med 2008; 36:669-675.
    • (2008) Crit. Care Med. , vol.36 , pp. 669-675
    • Cressoni, M.1    Caironi, P.2    Polli, F.3
  • 6
    • 0019951960 scopus 로고
    • Normal values of functional residual capacity in the sitting and supine positions
    • Ibanez J, Raurich JM. Normal values of functional residual capacity in the sitting and supine positions. Intensive Care Med 1982; 8:173-177.
    • (1982) Intensive Care Med. , vol.8 , pp. 173-177
    • Ibanez, J.1    Raurich, J.M.2
  • 7
    • 26444474718 scopus 로고    scopus 로고
    • The effects of anesthesia and muscle paralysis on the respiratory system
    • Hedenstierna G, Edmark L. The effects of anesthesia and muscle paralysis on the respiratory system. Intensive Care Med 2005; 31:1327-1335.
    • (2005) Intensive Care Med. , vol.31 , pp. 1327-1335
    • Hedenstierna, G.1    Edmark, L.2
  • 9
    • 0020136065 scopus 로고
    • A simple method for measuring the effect of PEEP on functional residual capacity during mechanical ventilation
    • Ibanez J, Raurich JM, Moris SG. A simple method for measuring the effect of PEEP on functional residual capacity during mechanical ventilation. Crit Care Med 1982; 10:332-334.
    • (1982) Crit. Care Med. , vol.10 , pp. 332-334
    • Ibanez, J.1    Raurich, J.M.2    Moris, S.G.3
  • 10
    • 20744452183 scopus 로고    scopus 로고
    • Estimation of functional residual capacity at the bedside using standard monitoring equipment: A modified nitrogen washout/washin technique requiring a small change of the inspired oxygen fraction
    • table
    • Olegard C, Sondergaard S, Houltz E, et al. Estimation of functional residual capacity at the bedside using standard monitoring equipment: a modified nitrogen washout/washin technique requiring a small change of the inspired oxygen fraction. Anesth Analg 2005; 101:206-212; table.
    • (2005) Anesth. Analg. , vol.101 , pp. 206-212
    • Olegard, C.1    Sondergaard, S.2    Houltz, E.3
  • 11
    • 76349084039 scopus 로고    scopus 로고
    • Validation and clinical feasibility of nitrogen washin/washout functional residual capacity measurements in children
    • Olegard C, Sondergaard S, Palsson J, et al. Validation and clinical feasibility of nitrogen washin/washout functional residual capacity measurements in children. Acta Anaesthesiol Scand 2010; 54:370-376.
    • (2010) Acta. Anaesthesiol. Scand. , vol.54 , pp. 370-376
    • Olegard, C.1    Sondergaard, S.2    Palsson, J.3
  • 12
    • 72449148665 scopus 로고    scopus 로고
    • Measurement of end-expiratory lung volume in intubated children without interruption of mechanical ventilation
    • Bikker IG, Scohy TV, Ad JJCB, et al. Measurement of end-expiratory lung volume in intubated children without interruption of mechanical ventilation. Intensive Care Med 2009; 35:1749-1753.
    • (2009) Intensive Care Med. , vol.35 , pp. 1749-1753
    • Bikker, I.G.1    Scohy, T.V.2    Ad, J.J.C.B.3
  • 13
    • 57649188013 scopus 로고    scopus 로고
    • End-expiratory lung volume during mechanical ventilation: A comparison with reference values and the effect of positive end-expiratory pressure in intensive care unit patients with different lung conditions
    • Bikker IG, Van Bommel J, Reis MD, et al. End-expiratory lung volume during mechanical ventilation: a comparison with reference values and the effect of positive end-expiratory pressure in intensive care unit patients with different lung conditions. Crit Care 2008; 12:R145.
    • (2008) Crit. Care , vol.12
    • Bikker, I.G.1    Van Bommel, J.2    Reis, M.D.3
  • 14
    • 33745828382 scopus 로고    scopus 로고
    • Positive end-Expiratory pressure optimization using electric impedance tomography in morbidly obese patients during laparoscopic gastric bypass surgery
    • Erlandsson K, Odenstedt H, Lundin S, Stenqvist O. Positive end-expiratory pressure optimization using electric impedance tomography in morbidly obese patients during laparoscopic gastric bypass surgery. Acta Anaesthesiol Scand 2006; 50:833-839.
    • (2006) Acta. Anaesthesiol. Scand. , vol.50 , pp. 833-839
    • Erlandsson, K.1    Odenstedt, H.2    Lundin, S.3    Stenqvist, O.4
  • 15
    • 57849092637 scopus 로고    scopus 로고
    • Nitrogen washout/washin, helium dilution and computed tomography in the assessment of end expiratory lung volume
    • Chiumello D, Cressoni M, Chierichetti M, et al. Nitrogen washout/washin, helium dilution and computed tomography in the assessment of end expiratory lung volume. Crit Care 2008; 12:R150.
    • (2008) Crit. Care , vol.12
    • Chiumello, D.1    Cressoni, M.2    Chierichetti, M.3
  • 16
    • 37549063974 scopus 로고    scopus 로고
    • Compliance and dead space fraction indicate an optimal level of positive end-expiratory pressure after recruitment in anesthetized patients
    • table
    • Maisch S, Reissmann H, Fuellekrug B, et al. Compliance and dead space fraction indicate an optimal level of positive end-expiratory pressure after recruitment in anesthetized patients. Anesth Analg 2008; 106:175-181; table
    • (2008) Anesth. Analg. , vol.106 , pp. 175-181
    • Maisch, S.1    Reissmann, H.2    Fuellekrug, B.3
  • 17
    • 80054871709 scopus 로고    scopus 로고
    • PEEP-induced changes in lung volume in acute respiratory distress syndrome two methods to estimate alveolar recruitment
    • Dellamonica J, Lerolle N, Sargentini C, et al. PEEP-induced changes in lung volume in acute respiratory distress syndrome. Two methods to estimate alveolar recruitment. Intensive Care Med 2011; 37:1595-1604.
    • (2011) Intensive Care Med. , vol.37 , pp. 1595-1604
    • Dellamonica, J.1    Lerolle, N.2    Sargentini, C.3
  • 18
    • 67650979230 scopus 로고    scopus 로고
    • Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels
    • Bikker IG, Leonhardt S, Bakker J, Gommers D. Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels. Intensive Care Med 2009; 35:1362-1367.
    • (2009) Intensive Care Med. , vol.35 , pp. 1362-1367
    • Bikker, I.G.1    Leonhardt, S.2    Bakker, J.3    Gommers, D.4
  • 19
    • 34547668792 scopus 로고    scopus 로고
    • Electric impedance tomography, the final frontier is close: The bedside reality
    • BrunowdC, FonsecaMC, Johnston C. Electric impedance tomography, the final frontier is close: the bedside reality. Crit Care Med 2007; 35:1996-1997.
    • (2007) Crit. Care Med. , vol.35 , pp. 1996-1997
    • Brunowd, C.1    Fonseca, M.C.2    Johnston, C.3
  • 20
    • 1642447778 scopus 로고    scopus 로고
    • Using electric impedance tomography to assess regional ventilation at the bedside
    • Hedenstierna G. Using electric impedance tomography to assess regional ventilation at the bedside. Am J Respir Crit Care Med 2004; 169:777-778.
    • (2004) Am. J. Respir. Crit. Care Med. , vol.169 , pp. 777-778
    • Hedenstierna, G.1
  • 21
    • 34249092005 scopus 로고    scopus 로고
    • Electrical impedance tomography guided ventilation therapy
    • Putensen C, Wrigge H, Zinserling J. Electrical impedance tomography guided ventilation therapy. Curr Opin Crit Care 2007; 13:344-350.
    • (2007) Curr. Opin. Crit. Care , vol.13 , pp. 344-350
    • Putensen, C.1    Wrigge, H.2    Zinserling, J.3
  • 23
    • 63349111376 scopus 로고    scopus 로고
    • Experimental case report: development of a pneumothorax monitored by electrical impedance tomography
    • Preis C, Luepschen H, Leonhardt S, Gommers D. Experimental case report: development of a pneumothorax monitored by electrical impedance tomography. Clin Physiol Funct Imaging 2009; 29:159-162.
    • (2009) Clin. Physiol. Funct Imaging , vol.29 , pp. 159-162
    • Preis, C.1    Luepschen, H.2    Leonhardt, S.3    Gommers, D.4
  • 24
    • 67349183203 scopus 로고    scopus 로고
    • Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography
    • Costa EL, Borges JB, Melo A, et al. Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography. Intensive Care Med 2009; 35:1132-1137.
    • (2009) Intensive Care Med. , vol.35 , pp. 1132-1137
    • Costa, E.L.1    Borges, J.B.2    Melo, A.3
  • 25
    • 43049127187 scopus 로고    scopus 로고
    • Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography
    • Meier T, Luepschen H, Karsten J, et al. Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography. Intensive Care Med 2008; 34:543-550.
    • (2008) Intensive Care Med. , vol.34 , pp. 543-550
    • Meier, T.1    Luepschen, H.2    Karsten, J.3
  • 26
    • 77952711577 scopus 로고    scopus 로고
    • Bedside measurement of changes in lung impedance to monitor alveolar ventilation in dependent and nondependent parts by electrical impedance tomography during a positive endexpiratory pressure trial in mechanically ventilated intensive care unit patients
    • Bikker IG, Leonhardt S, Reis MD, et al. Bedside measurement of changes in lung impedance to monitor alveolar ventilation in dependent and nondependent parts by electrical impedance tomography during a positive endexpiratory pressure trial in mechanically ventilated intensive care unit patients. Crit Care 2010; 14:R100.
    • (2010) Crit. Care , vol.14
    • Bikker, I.G.1    Leonhardt, S.2    Reis, M.D.3
  • 27
    • 80051488276 scopus 로고    scopus 로고
    • Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial
    • Bikker IG, Preis C, Egal M, et al. Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial. Crit Care 2011; 15:R193. In this article, EIT is used at two levels and showed a different ventilation pattern during a PEEP trial in mechanically ventilated ICU patients.
    • (2011) Crit. Care , vol.15
    • Bikker, I.G.1    Preis, C.2    Egal, M.3
  • 28
    • 78651255186 scopus 로고    scopus 로고
    • Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome: assessed by electric impedance tomography
    • Lowhagen K, Lundin S, Stenqvist O. Regional intratidal gas distribution in acute lung injury and acute respiratory distress syndrome: assessed by electric impedance tomography. Minerva Anestesiol 2010; 76:1024-1035.
    • (2010) Minerva Anestesiol. , vol.76 , pp. 1024-1035
    • Lowhagen, K.1    Lundin, S.2    Stenqvist, O.3
  • 29
    • 80051934375 scopus 로고    scopus 로고
    • Heart-lung interactions measured by electrical impedance tomography
    • Maisch S, Bohm SH, Sola J, et al. Heart-lung interactions measured by electrical impedance tomography. Crit Care Med 2011; 39:2173-2176.
    • (2011) Crit. Care Med. , vol.39 , pp. 2173-2176
    • Maisch, S.1    Bohm, S.H.2    Sola, J.3
  • 30
    • 33947655985 scopus 로고    scopus 로고
    • Regional distribution of acoustic-based lung vibration as a function of mechanical ventilation mode
    • Dellinger RP, Jean S, Cinel I, et al. Regional distribution of acoustic-based lung vibration as a function of mechanical ventilation mode. Crit Care 2007; 11:R26.
    • (2007) Crit. Care , vol.11
    • Dellinger, R.P.1    Jean, S.2    Cinel, I.3
  • 31
    • 78649299912 scopus 로고    scopus 로고
    • Computerized lung acoustic monitoring can help to differentiate between various chest radiographic densities in critically ill patients
    • Lev S, Glickman YA, Kagan I, et al. Computerized lung acoustic monitoring can help to differentiate between various chest radiographic densities in critically ill patients. Respiration 2010; 80:509-516.
    • (2010) Respiration , vol.80 , pp. 509-516
    • Lev, S.1    Glickman, Y.A.2    Kagan, I.3
  • 32
    • 0026691707 scopus 로고
    • Evaluation of respiratory inductive plethysmography in the measurement of breathing pattern and PEEP-induced changes in lung volume
    • Valta P, Takala J, Foster R, et al. Evaluation of respiratory inductive plethysmography in the measurement of breathing pattern and PEEP-induced changes in lung volume. Chest 1992; 102:234-238.
    • (1992) Chest , vol.102 , pp. 234-238
    • Valta, P.1    Takala, J.2    Foster, R.3
  • 33
    • 80054044252 scopus 로고    scopus 로고
    • Respiratory-inductive-plethysmography- derived flow can be a useful clinical tool to detect patients with obstructive sleep apnea syndrome
    • Yang GG, Yang MC, Chung CY, et al. Respiratory-inductive-plethysmography- derived flow can be a useful clinical tool to detect patients with obstructive sleep apnea syndrome. J Formos Med Assoc 2011; 110:642-645.
    • (2011) J. Formos Med. Assoc. , vol.110 , pp. 642-645
    • Yang, G.G.1    Yang, M.C.2    Chung, C.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.