메뉴 건너뛰기




Volumn 27, Issue 3, 2012, Pages 323.e11-323.e18

Regional lung opening and closing pressures in patients with acute lung injury

Author keywords

Acute lung injury; EIT; Electrical impedance tomography; Regional lung closing pressure; Regional lung opening pressure

Indexed keywords

ACUTE LUNG INJURY; ADULT; AGED; AIRWAY PRESSURE; ARTICLE; CLINICAL ARTICLE; COMPUTER ASSISTED IMPEDANCE TOMOGRAPHY; CONTROLLED STUDY; GAS FLOW; HUMAN; LUNG COLLAPSE; LUNG INFLATION; LUNG MECHANICS; LUNG PRESSURE; OPTICAL RESOLUTION; POSITIVE END EXPIRATORY PRESSURE; REGIONAL LUNG CLOSING PRESSURE; REGIONAL LUNG OPENING PRESSURE; VENTILATED PATIENT;

EID: 84861201824     PISSN: 08839441     EISSN: 15578615     Source Type: Journal    
DOI: 10.1016/j.jcrc.2011.09.002     Document Type: Article
Times cited : (52)

References (34)
  • 1
    • 33646115657 scopus 로고    scopus 로고
    • Lung recruitment in patients with the acute respiratory distress syndrome
    • Gattinoni L., Caironi P., Cressoni M., et al. Lung recruitment in patients with the acute respiratory distress syndrome. N Engl J Med 2006, 354:1775-1786.
    • (2006) N Engl J Med , vol.354 , pp. 1775-1786
    • Gattinoni, L.1    Caironi, P.2    Cressoni, M.3
  • 2
    • 0345436055 scopus 로고    scopus 로고
    • Effect of mechanical ventilation on inflammatory mediators in patients with acute respiratory distress syndrome: a randomized controlled trial
    • Ranieri V.M., Suter P.M., Tortorella C., et al. Effect of mechanical ventilation on inflammatory mediators in patients with acute respiratory distress syndrome: a randomized controlled trial. JAMA 1999, 282:54-61.
    • (1999) JAMA , vol.282 , pp. 54-61
    • Ranieri, V.M.1    Suter, P.M.2    Tortorella, C.3
  • 3
    • 77749316982 scopus 로고    scopus 로고
    • Lung opening and closing during ventilation of acute respiratory distress syndrome
    • Caironi P., Cressoni M., Chiumello D., et al. Lung opening and closing during ventilation of acute respiratory distress syndrome. Am J Respir Crit Care Med 2010, 181:578-586.
    • (2010) Am J Respir Crit Care Med , vol.181 , pp. 578-586
    • Caironi, P.1    Cressoni, M.2    Chiumello, D.3
  • 4
    • 0032772434 scopus 로고    scopus 로고
    • Lung injury caused by mechanical ventilation
    • Slutsky A.S. Lung injury caused by mechanical ventilation. Chest 1999, 116:9S-15S.
    • (1999) Chest , vol.116
    • Slutsky, A.S.1
  • 5
    • 0036084003 scopus 로고    scopus 로고
    • Ventilation-induced lung injury and mechanotransduction: stretching it too far?
    • Uhlig S. Ventilation-induced lung injury and mechanotransduction: stretching it too far?. Am J Physiol Lung Cell Mol Physiol 2002, 282:L892-L896.
    • (2002) Am J Physiol Lung Cell Mol Physiol , vol.282
    • Uhlig, S.1
  • 6
    • 0035402374 scopus 로고    scopus 로고
    • Recruitment and derecruitment during acute respiratory failure: a clinical study
    • Crotti S., Mascheroni D., Caironi P., et al. Recruitment and derecruitment during acute respiratory failure: a clinical study. Am J Respir Crit Care Med 2001, 164:131-140.
    • (2001) Am J Respir Crit Care Med , vol.164 , pp. 131-140
    • Crotti, S.1    Mascheroni, D.2    Caironi, P.3
  • 7
    • 0035402479 scopus 로고    scopus 로고
    • Recruitment and derecruitment during acute respiratory failure: an experimental study
    • Pelosi P., Goldner M., McKibben A., et al. Recruitment and derecruitment during acute respiratory failure: an experimental study. Am J Respir Crit Care Med 2001, 164:122-130.
    • (2001) Am J Respir Crit Care Med , vol.164 , pp. 122-130
    • Pelosi, P.1    Goldner, M.2    McKibben, A.3
  • 8
    • 0344676398 scopus 로고    scopus 로고
    • Effects of recruitment maneuvers in patients with acute lung injury and acute respiratory distress syndrome ventilated with high positive end-expiratory pressure
    • Brower R.G., Morris A., MacIntyre N., et al. Effects of recruitment maneuvers in patients with acute lung injury and acute respiratory distress syndrome ventilated with high positive end-expiratory pressure. Crit Care Med 2003, 31:2592-2597.
    • (2003) Crit Care Med , vol.31 , pp. 2592-2597
    • Brower, R.G.1    Morris, A.2    MacIntyre, N.3
  • 9
    • 0031844273 scopus 로고    scopus 로고
    • The pressure-volume curve is greatly modified by recruitment. A mathematical model of ARDS lungs
    • Hickling K.G. The pressure-volume curve is greatly modified by recruitment. A mathematical model of ARDS lungs. Am J Respir Crit Care Med 1998, 158:194-202.
    • (1998) Am J Respir Crit Care Med , vol.158 , pp. 194-202
    • Hickling, K.G.1
  • 10
    • 33746585210 scopus 로고    scopus 로고
    • Reversibility of lung collapse and hypoxemia in early acute respiratory distress syndrome
    • Borges J.B., Okamoto V.N., Matos G.F., et al. Reversibility of lung collapse and hypoxemia in early acute respiratory distress syndrome. Am J Respir Crit Care Med 2006, 174:268-278.
    • (2006) Am J Respir Crit Care Med , vol.174 , pp. 268-278
    • Borges, J.B.1    Okamoto, V.N.2    Matos, G.F.3
  • 11
    • 1842738372 scopus 로고    scopus 로고
    • Airway pressure-time curve profile (stress index) detects tidal recruitment/hyperinflation in experimental acute lung injury
    • Grasso S., Terragni P., Mascia L., et al. Airway pressure-time curve profile (stress index) detects tidal recruitment/hyperinflation in experimental acute lung injury. Crit Care Med 2004, 32:1018-1027.
    • (2004) Crit Care Med , vol.32 , pp. 1018-1027
    • Grasso, S.1    Terragni, P.2    Mascia, L.3
  • 12
    • 0027417772 scopus 로고
    • Regional effects and mechanism of positive end-expiratory pressure in early adult respiratory distress syndrome
    • Gattinoni L., D'Andrea L., Pelosi P., et al. Regional effects and mechanism of positive end-expiratory pressure in early adult respiratory distress syndrome. JAMA 1993, 269:2122-2127.
    • (1993) JAMA , vol.269 , pp. 2122-2127
    • Gattinoni, L.1    D'Andrea, L.2    Pelosi, P.3
  • 13
    • 0033406744 scopus 로고    scopus 로고
    • International consensus conferences in intensive care medicine: ventilator-associated Lung injury in ARDS. This official conference report was cosponsored by the American Thoracic Society, The European Society of Intensive Care Medicine, and The Societe de Reanimation de Langue Francaise, and was approved by the ATS Board of Directors, July 1999
    • International consensus conferences in intensive care medicine: ventilator-associated Lung injury in ARDS. This official conference report was cosponsored by the American Thoracic Society, The European Society of Intensive Care Medicine, and The Societe de Reanimation de Langue Francaise, and was approved by the ATS Board of Directors, July 1999. Am J Respir Crit Care Med 1999, 160:2118-2124.
    • (1999) Am J Respir Crit Care Med , vol.160 , pp. 2118-2124
  • 14
    • 12144287431 scopus 로고    scopus 로고
    • Imbalances in regional lung ventilation: a validation study on electrical impedance tomography
    • Victorino J.A., Borges J.B., Okamoto V.N., et al. Imbalances in regional lung ventilation: a validation study on electrical impedance tomography. Am J Respir Crit Care Med 2004, 169:791-800.
    • (2004) Am J Respir Crit Care Med , vol.169 , pp. 791-800
    • Victorino, J.A.1    Borges, J.B.2    Okamoto, V.N.3
  • 15
    • 0036021827 scopus 로고    scopus 로고
    • Detection of local lung air content by electrical impedance tomography compared with electron beam CT
    • Frerichs I., Hinz J., Herrmann P., et al. Detection of local lung air content by electrical impedance tomography compared with electron beam CT. J Appl Physiol 2002, 93:660-666.
    • (2002) J Appl Physiol , vol.93 , pp. 660-666
    • Frerichs, I.1    Hinz, J.2    Herrmann, P.3
  • 16
    • 41649114496 scopus 로고    scopus 로고
    • Electrical impedance tomography compared with thoracic computed tomography during a slow inflation maneuver in experimental models of lung injury
    • Wrigge H., Zinserling J., Muders T., et al. Electrical impedance tomography compared with thoracic computed tomography during a slow inflation maneuver in experimental models of lung injury. Crit Care Med 2008, 36:903-909.
    • (2008) Crit Care Med , vol.36 , pp. 903-909
    • Wrigge, H.1    Zinserling, J.2    Muders, T.3
  • 17
    • 77649305606 scopus 로고    scopus 로고
    • PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography
    • Zhao Z., Steinmann D., Frerichs I., et al. PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomography. Crit Care 2010, 14:R8.
    • (2010) Crit Care , vol.14
    • Zhao, Z.1    Steinmann, D.2    Frerichs, I.3
  • 18
    • 67349183203 scopus 로고    scopus 로고
    • Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography
    • Costa E.L., Borges J.B., Melo A., et al. Bedside estimation of recruitable alveolar collapse and hyperdistension by electrical impedance tomography. Intensive Care Med 2009, 35:1132-1137.
    • (2009) Intensive Care Med , vol.35 , pp. 1132-1137
    • Costa, E.L.1    Borges, J.B.2    Melo, A.3
  • 19
    • 78651505720 scopus 로고    scopus 로고
    • Prolonged moderate pressure recruitment manoeuvre results in lower optimal positive end-expiratory pressure and plateau pressure
    • Lowhagen K., Lindgren S., Odenstedt H., et al. Prolonged moderate pressure recruitment manoeuvre results in lower optimal positive end-expiratory pressure and plateau pressure. Acta Anaesthesiol Scand 2011, 55:175-184.
    • (2011) Acta Anaesthesiol Scand , vol.55 , pp. 175-184
    • Lowhagen, K.1    Lindgren, S.2    Odenstedt, H.3
  • 20
    • 77952711577 scopus 로고    scopus 로고
    • Bedside measurement of changes in lung impedance to monitor alveolar ventilation in dependent and non-dependent parts by electrical impedance tomography during a positive end-expiratory pressure trial in mechanically ventilated intensive care unit patients
    • Bikker I.G., Leonhardt S., Reis Miranda D., et al. Bedside measurement of changes in lung impedance to monitor alveolar ventilation in dependent and non-dependent parts by electrical impedance tomography during a positive end-expiratory pressure trial in mechanically ventilated intensive care unit patients. Crit Care 2010, 14:R100.
    • (2010) Crit Care , vol.14
    • Bikker, I.G.1    Leonhardt, S.2    Reis Miranda, D.3
  • 21
    • 78650417000 scopus 로고    scopus 로고
    • Regional tidal ventilation and compliance during a stepwise vital capacity manoeuvre
    • Dargaville P.A., Rimensberger P.C., Frerichs I. Regional tidal ventilation and compliance during a stepwise vital capacity manoeuvre. Intensive Care Med 2010, 36:1953-1961.
    • (2010) Intensive Care Med , vol.36 , pp. 1953-1961
    • Dargaville, P.A.1    Rimensberger, P.C.2    Frerichs, I.3
  • 22
    • 43049127187 scopus 로고    scopus 로고
    • Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography
    • Meier T., Luepschen H., Karsten J., et al. Assessment of regional lung recruitment and derecruitment during a PEEP trial based on electrical impedance tomography. Intensive Care Med 2008, 34:543-550.
    • (2008) Intensive Care Med , vol.34 , pp. 543-550
    • Meier, T.1    Luepschen, H.2    Karsten, J.3
  • 23
    • 0028267785 scopus 로고
    • The American-European Consensus Conference on ARDS. Definitions, mechanisms, relevant outcomes, and clinical trial coordination
    • Bernard G.R., Artigas A., Brigham K.L., et al. The American-European Consensus Conference on ARDS. Definitions, mechanisms, relevant outcomes, and clinical trial coordination. Am J Respir Crit Care Med 1994, 149:818-824.
    • (1994) Am J Respir Crit Care Med , vol.149 , pp. 818-824
    • Bernard, G.R.1    Artigas, A.2    Brigham, K.L.3
  • 24
    • 0033995054 scopus 로고    scopus 로고
    • A simple method to check the dynamic performance of electrical impedance tomography systems
    • Hahn G., Beer M., Frerichs I., et al. A simple method to check the dynamic performance of electrical impedance tomography systems. Physiol Meas 2000, 21:53-60.
    • (2000) Physiol Meas , vol.21 , pp. 53-60
    • Hahn, G.1    Beer, M.2    Frerichs, I.3
  • 25
    • 70149113909 scopus 로고    scopus 로고
    • GREIT: a unified approach to 2D linear EIT reconstruction of lung images
    • Adler A., Arnold J.H., Bayford R., et al. GREIT: a unified approach to 2D linear EIT reconstruction of lung images. Physiol Meas 2009, 30:S35-55.
    • (2009) Physiol Meas , vol.30
    • Adler, A.1    Arnold, J.H.2    Bayford, R.3
  • 26
    • 0032484956 scopus 로고    scopus 로고
    • Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome
    • Amato M.B., Barbas C.S., Medeiros D.M., et al. Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome. N Engl J Med 1998, 338:347-354.
    • (1998) N Engl J Med , vol.338 , pp. 347-354
    • Amato, M.B.1    Barbas, C.S.2    Medeiros, D.M.3
  • 27
    • 56249128276 scopus 로고    scopus 로고
    • Mechanical ventilation guided by esophageal pressure in acute lung injury
    • Talmor D., Sarge T., Malhotra A., et al. Mechanical ventilation guided by esophageal pressure in acute lung injury. N Engl J Med 2008, 359:2095-2104.
    • (2008) N Engl J Med , vol.359 , pp. 2095-2104
    • Talmor, D.1    Sarge, T.2    Malhotra, A.3
  • 28
    • 0031730518 scopus 로고    scopus 로고
    • A computed tomography scan assessment of regional lung volume in acute lung injury. The CT Scan ARDS Study Group
    • Puybasset L., Cluzel P., Chao N., et al. A computed tomography scan assessment of regional lung volume in acute lung injury. The CT Scan ARDS Study Group. Am J Respir Crit Care Med 1998, 158:1644-1655.
    • (1998) Am J Respir Crit Care Med , vol.158 , pp. 1644-1655
    • Puybasset, L.1    Cluzel, P.2    Chao, N.3
  • 29
    • 0022652254 scopus 로고
    • Morphological response to positive end expiratory pressure in acute respiratory failure. Computerized tomography study
    • Gattinoni L., Mascheroni D., Torresin A., et al. Morphological response to positive end expiratory pressure in acute respiratory failure. Computerized tomography study. Intensive Care Med 1986, 12:137-142.
    • (1986) Intensive Care Med , vol.12 , pp. 137-142
    • Gattinoni, L.1    Mascheroni, D.2    Torresin, A.3
  • 30
    • 0348225234 scopus 로고    scopus 로고
    • Electrical impedance tomography: a method for monitoring regional lung aeration and tidal volume distribution?
    • Frerichs I., Dargaville P.A., Dudykevych T., et al. Electrical impedance tomography: a method for monitoring regional lung aeration and tidal volume distribution?. Intensive Care Med 2003, 29:2312-2316.
    • (2003) Intensive Care Med , vol.29 , pp. 2312-2316
    • Frerichs, I.1    Dargaville, P.A.2    Dudykevych, T.3
  • 31
    • 0025826072 scopus 로고
    • CT scan in ARDS: clinical and physiopathological insights
    • [discussion 94-86]
    • Gattinoni L., Pelosi P., Pesenti A., et al. CT scan in ARDS: clinical and physiopathological insights. Acta Anaesthesiol Scand Suppl 1991, 95:87-94. [discussion 94-86].
    • (1991) Acta Anaesthesiol Scand Suppl , vol.95 , pp. 87-94
    • Gattinoni, L.1    Pelosi, P.2    Pesenti, A.3
  • 32
    • 0038159723 scopus 로고    scopus 로고
    • Regional ventilation by electrical impedance tomography: a comparison with ventilation scintigraphy in pigs
    • Hinz J., Neumann P., Dudykevych T., et al. Regional ventilation by electrical impedance tomography: a comparison with ventilation scintigraphy in pigs. Chest 2003, 124:314-322.
    • (2003) Chest , vol.124 , pp. 314-322
    • Hinz, J.1    Neumann, P.2    Dudykevych, T.3
  • 33
    • 67649422713 scopus 로고    scopus 로고
    • Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study
    • Richard J.C., Pouzot C., Gros A., et al. Electrical impedance tomography compared to positron emission tomography for the measurement of regional lung ventilation: an experimental study. Crit Care 2009, 13:R82.
    • (2009) Crit Care , vol.13
    • Richard, J.C.1    Pouzot, C.2    Gros, A.3
  • 34
    • 0031791107 scopus 로고    scopus 로고
    • Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning
    • Kunst P.W., Vonk Noordegraaf A., Hoekstra O.S., et al. Ventilation and perfusion imaging by electrical impedance tomography: a comparison with radionuclide scanning. Physiol Meas 1998, 19:481-490.
    • (1998) Physiol Meas , vol.19 , pp. 481-490
    • Kunst, P.W.1    Vonk Noordegraaf, A.2    Hoekstra, O.S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.