메뉴 건너뛰기




Volumn 57, Issue 11, 2012, Pages 3295-3308

A modular method to handle multiple time-dependent quantities in Monte Carlo simulations

Author keywords

[No Author keywords available]

Indexed keywords

BEAM CURRENTS; BEAM SCATTERING; BRAGG PEAK POSITIONS; BRAGG PEAKS; CLINICAL SITUATIONS; DOSE CALCULATION; ENERGY DISTRIBUTIONS; FLUENCES; GENERAL METHOD; GEOMETRICAL OBJECTS; MASSACHUSETTS; MEDICAL COMMUNITY; MODULAR METHODS; MODULAR STRUCTURES; MONTE CARLO SIMULATION; PARTICLE SIMULATIONS; PULSE SHAPES; SCANNING MODE; TIME DEPENDENT SIMULATION; TIME FEATURES; TIME RESOLUTION; TIME VALUES; TIME-DEPENDENT; TIME-DEPENDENT CHANGES; UNIFORM DISTRIBUTION; UNIVERSITY OF CALIFORNIA; WATER COLUMNS;

EID: 84861146892     PISSN: 00319155     EISSN: 13616560     Source Type: Journal    
DOI: 10.1088/0031-9155/57/11/3295     Document Type: Article
Times cited : (22)

References (19)
  • 1
    • 0038377458 scopus 로고    scopus 로고
    • Geant4 - A simulation toolkit
    • 10.1016/S0168-9002(03)01368-8 0168-9002 A
    • Agostinelli S et al 2003 Geant4 - a simulation toolkit Nucl. Instrum. Methods Phys. Res A 506 250303
    • (2003) Nucl. Instrum. Methods Phys. Res , vol.506 , Issue.3 , pp. 250-303
    • Agostinelli, S.1
  • 2
    • 79551675095 scopus 로고    scopus 로고
    • Position-probability-sampled Monte Carlo calculation of VMAT, 3DCRT, step-shoot IMRT, and helical tomotherapy dose distributions using BEAMnrc/DOSXYZnrc
    • 10.1118/1.3538922 0094-2405
    • Belec J, Ploquin N, La Russa D J and Clark B G 2011 Position-probability- sampled Monte Carlo calculation of VMAT, 3DCRT, step-shoot IMRT, and helical tomotherapy dose distributions using BEAMnrc/DOSXYZnrc Med. Phys. 38 94860
    • (2011) Med. Phys. , vol.38 , Issue.2 , pp. 948-960
    • Belec, J.1    Ploquin, N.2    La Russa, D.J.3    Clark, B.G.4
  • 3
    • 0000277337 scopus 로고
    • Instrumentation for treatment of cancer using proton and light-ion beams
    • 10.1063/1.1143946 0034-6748
    • Chu W T, Ludewigt B T and Renner T R 1993 Instrumentation for treatment of cancer using proton and light-ion beams Rev. Sci. Instrum. 64 2055122
    • (1993) Rev. Sci. Instrum. , vol.64 , Issue.8 , pp. 2055-2122
    • Chu, W.T.1    Ludewigt, B.T.2    Renner, T.R.3
  • 4
    • 23844458377 scopus 로고    scopus 로고
    • The Geant4 geometry modeler
    • N44-9, 2004 IEEE Nuclear Science Symposium Conference Record
    • Cosmo G 2004 The Geant4 geometry modeler IEEE Nuclear Sci. Symp. Conf. Record pp 21968 (Pubitemid 41148016)
    • (2004) IEEE Nuclear Science Symposium Conference Record , vol.4 , pp. 2196-2198
    • Cosmo, G.1
  • 6
    • 0342444673 scopus 로고
    • Tissuephantom ratios - An aid to treatment planning
    • 10.1259/0007-1285-38-446-158 0007-1285
    • Karzmark C J, Deubert A and Loevinger R 1965 Tissuephantom ratios - an aid to treatment planning Br. J. Radiol. 38 158
    • (1965) Br. J. Radiol. , vol.38 , Issue.446 , pp. 158
    • Karzmark, C.J.1    Deubert, A.2    Loevinger, R.3
  • 8
    • 0016626426 scopus 로고
    • Range modulators for protons and heavy ions
    • 10.1016/0029-554X(75)90430-9 0029-554X
    • Koehler A M, Schneider R J and Sisterson J M 1975 Range modulators for protons and heavy ions Nucl. Instrum. Methods 131 43740
    • (1975) Nucl. Instrum. Methods , vol.131 , Issue.3 , pp. 437-440
    • Koehler, A.M.1    Schneider, R.J.2    Sisterson, J.M.3
  • 9
    • 0034834060 scopus 로고    scopus 로고
    • A method of simulating dynamic multileaf collimators using Monte Carlo techniques for intensity-modulated radiation therapy
    • DOI 10.1088/0031-9155/46/9/302, PII S0031915501224749
    • Liu H H, Verhaegen F and Dong L 2001 A method of simulating dynamic multileaf collimators using Monte Carlo techniques for intensity-modulated radiation therapy Phys. Med. Biol. 46 228398 (Pubitemid 32895528)
    • (2001) Physics in Medicine and Biology , vol.46 , Issue.9 , pp. 2283-2298
    • Liu, H.H.1    Verhaegen, F.2    Dong, L.3
  • 10
    • 34748843943 scopus 로고    scopus 로고
    • Sensitivities in the production of spread-out Bragg peak dose distributions by passive scattering with beam current modulation
    • DOI 10.1118/1.2776255
    • Lu H-M, Brett R, Engelsman M, Slopsema R, Kooy H and Flanz J 2007 Sensitivities in the production of spread-out Bragg peak dose distributions by passive scattering with beam current modulation Med. Phys. 34 384453 (Pubitemid 47482886)
    • (2007) Medical Physics , vol.34 , Issue.10 , pp. 3844-3853
    • Lu, H.-M.1    Brett, R.2    Engelsman, M.3    Slopsema, R.4    Kooy, H.5    Flanz, J.6
  • 11
    • 1642446494 scopus 로고    scopus 로고
    • Four-dimensional Monte Carlo simulation of time-dependent geometries
    • 0031-9155 N03
    • Paganetti H 2004 Four-dimensional Monte Carlo simulation of time-dependent geometries Phys. Med. Biol. 49 N7581
    • (2004) Phys. Med. Biol. , vol.49 , Issue.6
    • Paganetti, H.1
  • 12
    • 33744782843 scopus 로고    scopus 로고
    • Monte Carlo calculations for absolute dosimetry to determine machine outputs for proton therapy fields
    • DOI 10.1088/0031-9155/51/11/008, PII S0031915506067455, 008
    • Paganetti H 2006 Monte Carlo calculations for absolute dosimetry to determine output factors for proton therapy fields Phys. Med. Biol. 51 280112 (Pubitemid 43832937)
    • (2006) Physics in Medicine and Biology , vol.51 , Issue.11 , pp. 2801-2812
    • Paganetti, H.1
  • 13
    • 0037962470 scopus 로고    scopus 로고
    • 2
    • DOI 10.1118/1.1586454
    • Paganetti H and Gottschalk B 2003 Test of Geant3 and Geant4 nuclear models for 160 MeV protons stopping in CH2 Med. Phys. 30 192631 (Pubitemid 36885811)
    • (2003) Medical Physics , vol.30 , Issue.7 , pp. 1926-1931
    • Paganetti, H.1    Gottschalk, B.2
  • 14
    • 3142702743 scopus 로고    scopus 로고
    • Accurate Monte Carlo simulations for nozzle design, commissioning and quality assurance for a proton radiation therapy facility
    • DOI 10.1118/1.1762792
    • Paganetti H, Jiang H, Lee S-Y and Kooy H M 2004 Accurate Monte Carlo simulations for nozzle design, commissioning and quality assurance for a proton radiation therapy facility Med. Phys. 31 210718 (Pubitemid 38924832)
    • (2004) Medical Physics , vol.31 , Issue.7 , pp. 2107-2118
    • Paganetti, H.1    Jiang, H.2    Lee, S.-Y.3    Kooy, H.M.4
  • 15
    • 51849122521 scopus 로고    scopus 로고
    • Clinical implementation of Monte Carlo dose calculation in proton beam therapy
    • 10.1088/0031-9155/53/17/023 0031-9155
    • Paganetti H, Jiang H, Parodi K, Slopsema R and Engelsman M 2008 Clinical implementation of Monte Carlo dose calculation in proton beam therapy Phys. Med. Biol. 53 482553
    • (2008) Phys. Med. Biol. , vol.53 , Issue.17 , pp. 4825-4853
    • Paganetti, H.1    Jiang, H.2    Parodi, K.3    Slopsema, R.4    Engelsman, M.5
  • 16
    • 16444381177 scopus 로고    scopus 로고
    • 4D Monte Carlo simulation of proton beam scanning: Modelling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry
    • DOI 10.1088/0031-9155/50/5/020
    • Paganetti H, Jiang H and Trofimov A 2005 4D Monte Carlo simulation of proton beam scanning: modelling of variations in time and space to study the interplay between scanning pattern and time-dependent patient geometry Phys. Med. Biol. 50 98390 (Pubitemid 40477318)
    • (2005) Physics in Medicine and Biology , vol.50 , Issue.5 , pp. 983-990
    • Paganetti, H.1    Jiang, H.2    Trofimov, A.3
  • 17
    • 85168636990 scopus 로고    scopus 로고
    • TOPAS: A fast and easy to use tool for particle simulation TU-C-BRB-08
    • 10.1118/1.3613128 0094-2405
    • Perl J, Schümann J, Shin J, Faddegon B and Paganetti H 2011 TOPAS: a fast and easy to use tool for particle simulation TU-C-BRB-08 Med. Phys. 38 37545
    • (2011) Med. Phys. , vol.38 , Issue.6 , pp. 3754-3755
    • Perl, J.1    Schümann, J.2    Shin, J.3    Faddegon, B.4    Paganetti, H.5
  • 18
    • 0032784755 scopus 로고    scopus 로고
    • Monte Carlo modelling of a virtual wedge
    • 0031-9155 402
    • Verhaegen F and Das I J 1999 Monte Carlo modelling of a virtual wedge Phys. Med. Biol. 44 N2519
    • (1999) Phys. Med. Biol. , vol.44 , Issue.12
    • Verhaegen, F.1    Das, I.J.2
  • 19
    • 0034819179 scopus 로고    scopus 로고
    • Incorporating dynamic collimator motion in Monte Carlo simulations: An application in modelling a dynamic wedge
    • 10.1088/0031-9155/46/2/302 0031-9155
    • Verhaegen F and Liu H H 2001 Incorporating dynamic collimator motion in Monte Carlo simulations: an application in modelling a dynamic wedge Phys. Med. Biol. 46 28796
    • (2001) Phys. Med. Biol. , vol.46 , Issue.2 , pp. 287-296
    • Verhaegen, F.1    Liu, H.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.