메뉴 건너뛰기




Volumn 89, Issue 5, 2012, Pages

Clinical application of ocular imaging

Author keywords

ocular imaging devices; optical coherence tomography; scanning laser ophthalmoscopy; scanning laser polarimetry

Indexed keywords

CLINICAL APPLICATION; CLINICAL MANAGEMENT; DIAGNOSTIC CAPABILITIES; EYE CARE; IMAGING MODALITY; OCULAR DISEASE; OCULAR IMAGING; POSTERIOR SEGMENT; SCANNING LASER OPHTHALMOSCOPY; SCANNING LASER POLARIMETRY;

EID: 84861099164     PISSN: 10405488     EISSN: None     Source Type: Journal    
DOI: 10.1097/OPX.0b013e31824f164d     Document Type: Review
Times cited : (16)

References (63)
  • 1
    • 33644811811 scopus 로고    scopus 로고
    • Microtubules contribute to the birefringence of the retinal nerve fiber layer
    • DOI 10.1167/iovs.05-0532
    • Huang XR, Knighton RW. Microtubules contribute to the birefringence of the retinal nerve fiber layer. Invest Ophthalmol Vis Sci 2005;46:4588-93. (Pubitemid 44264558)
    • (2005) Investigative Ophthalmology and Visual Science , vol.46 , Issue.12 , pp. 4588-4593
    • Huang, X.-R.1    Knighton, R.W.2
  • 2
    • 0029044003 scopus 로고
    • Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes
    • Weinreb RN, Shakiba S, Zangwill L. Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes. Am J Ophthalmol 1995;119:627-36.
    • (1995) Am J Ophthalmol , vol.119 , pp. 627-636
    • Weinreb, R.N.1    Shakiba, S.2    Zangwill, L.3
  • 3
    • 4744356184 scopus 로고    scopus 로고
    • Diagnostic accuracy of the GDx VCC for glaucoma
    • DOI 10.1016/j.ophtha.2004.04.024, PII S0161642004008206
    • Reus NJ, Lemij HG. Diagnostic accuracy of the GDx VCC for glaucoma. Ophthalmology 2004;111:1860-5. (Pubitemid 39311837)
    • (2004) Ophthalmology , vol.111 , Issue.10 , pp. 1860-1865
    • Reus, N.J.1    Lemij, H.G.2
  • 5
    • 33746407603 scopus 로고    scopus 로고
    • Comparison between GDx VCC parameter and achromatic perimetry in glaucoma patients
    • DOI 10.1097/01.ijg.0000212235.88416.bd, PII 0006119820060800000002
    • Iester M, Perdicchi A, De Feo F, Fiesoletti E, Amodeo S, Sanna G, Leonardi A, Calabria G. Comparison between GDx VCC parameter Clinical Application of Ocular Imaging\Nadler et al. E551 and achromatic perimetry in glaucoma patients. J Glaucoma 2006; 15:281-5. (Pubitemid 44126901)
    • (2006) Journal of Glaucoma , vol.15 , Issue.4 , pp. 281-285
    • Iester, M.1    Perdicchi, A.2    De Feo, F.3    Fiesoletti, E.4    Amodeo, S.5    Sanna, G.6    Leonardi, A.7    Calabria, G.8
  • 6
    • 48149087056 scopus 로고    scopus 로고
    • Comparison of retinal nerve fiber layer and optic disc imaging for diagnosing glaucoma in patients suspected of having the disease
    • Medeiros FA, Vizzeri G, Zangwill LM, Alencar LM, Sample PA, Weinreb RN. Comparison of retinal nerve fiber layer and optic disc imaging for diagnosing glaucoma in patients suspected of having the disease. Ophthalmology 2008;115:1340-6.
    • (2008) Ophthalmology , vol.115 , pp. 1340-1346
    • Medeiros, F.A.1    Vizzeri, G.2    Zangwill, L.M.3    Alencar, L.M.4    Sample, P.A.5    Weinreb, R.N.6
  • 9
    • 38649091069 scopus 로고    scopus 로고
    • State-of-The-art retinal optical coherence tomography
    • DOI 10.1016/j.preteyeres.2007.07.005, PII S1350946207000444
    • Drexler W, Fujimoto JG. State-of-the-art retinal optical coherence tomography. Prog Retin Eye Res 2008;27:45-88. (Pubitemid 351165776)
    • (2008) Progress in Retinal and Eye Research , vol.27 , Issue.1 , pp. 45-88
    • Drexler, W.1    Fujimoto, J.G.2
  • 10
    • 25844456000 scopus 로고    scopus 로고
    • Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography
    • DOI 10.1016/j.ophtha.2005.05.023, PII S016164200500816X
    • Wojtkowski M, Srinivasan V, Fujimoto JG, Ko T, Schuman JS, Kowalczyk A, Duker JS. Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography. Ophthalmology 2005;112:1734-46. (Pubitemid 41400010)
    • (2005) Ophthalmology , vol.112 , Issue.10 , pp. 1734-1746
    • Wojtkowski, M.1    Srinivasan, V.2    Fujimoto, J.G.3    Ko, T.4    Schuman, J.S.5    Kowalczyk, A.6    Duker, J.S.7
  • 13
    • 84861099241 scopus 로고    scopus 로고
    • Optical coherence tomography findings in idiopathic macular holes
    • Huang LL, Levinson DH, Levine JP, Mian U, Tsui I. Optical coherence tomography findings in idiopathic macular holes. J Ophthalmol 2011;2011:928205.
    • (2011) J Ophthalmol , vol.2011 , pp. 928205
    • Huang, L.L.1    Levinson, D.H.2    Levine, J.P.3    Mian, U.4    Tsui, I.5
  • 14
    • 0034042676 scopus 로고    scopus 로고
    • Diagnosis of vitreoretinal adhesions in macular disease with optical coherence tomography
    • Gallemore RP, Jumper JM, McCuen BW, II, Jaffe GJ, Postel EA, Toth CA. Diagnosis of vitreoretinal adhesions in macular disease with optical coherence tomography. Retina 2000;20:115-20. (Pubitemid 30395704)
    • (2000) Retina , vol.20 , Issue.2 , pp. 115-120
    • Gallemore, R.P.1    Jumper, J.M.2    McCuen II, B.W.3    Jaffe, G.J.4    Postel, E.A.5    Toth, C.A.6
  • 16
    • 61349196181 scopus 로고    scopus 로고
    • Photoreceptor layer thinning over drusen in eyes with age-related macular degeneration imaged in vivo with spectral-domain optical coherence tomography
    • Schuman SG, Koreishi AF, Farsiu S, Jung SH, Izatt JA, Toth CA. Photoreceptor layer thinning over drusen in eyes with age-related macular degeneration imaged in vivo with spectral-domain optical coherence tomography. Ophthalmology 2009;116:488-96.
    • (2009) Ophthalmology , vol.116 , pp. 488-496
    • Schuman, S.G.1    Koreishi, A.F.2    Farsiu, S.3    Jung, S.H.4    Izatt, J.A.5    Toth, C.A.6
  • 18
    • 60849134576 scopus 로고    scopus 로고
    • Spectral domain optical coherence tomography for quantitative evaluation of drusen and associated structural changes in non-neovascular age-related macular degeneration
    • Yi K, Mujat M, Park BH, Sun W, Miller JW, Seddon JM, Young LH, de Boer JF, Chen TC. Spectral domain optical coherence tomography for quantitative evaluation of drusen and associated structural changes in non-neovascular age-related macular degeneration. Br J Ophthalmol 2009;93:176-81.
    • (2009) Br J Ophthalmol , vol.93 , pp. 176-181
    • Yi, K.1    Mujat, M.2    Park, B.H.3    Sun, W.4    Miller, J.W.5    Seddon, J.M.6    Young, L.H.7    De Boer, J.F.8    Chen, T.C.9
  • 19
    • 77949365149 scopus 로고    scopus 로고
    • Optical coherence tomography-raster scanning and manual segmentation in determining drusen volume in age-related macular degeneration
    • Freeman SR, Kozak I, Cheng L, Bartsch DU, Mojana F, Nigam N, Brar M, Yuson R, Freeman WR. Optical coherence tomography-raster scanning and manual segmentation in determining drusen volume in age-related macular degeneration. Retina 2010;30:431-5.
    • (2010) Retina , vol.30 , pp. 431-435
    • Freeman, S.R.1    Kozak, I.2    Cheng, L.3    Bartsch, D.U.4    Mojana, F.5    Nigam, N.6    Brar, M.7    Yuson, R.8    Freeman, W.R.9
  • 20
    • 59749087841 scopus 로고    scopus 로고
    • Spectral-domain optical coherence tomography images of inner/outer segment junctions and macular hole surgery outcomes
    • Inoue M, Watanabe Y, Arakawa A, Sato S, Kobayashi S, Kadonosono K. Spectral-domain optical coherence tomography images of inner/outer segment junctions and macular hole surgery outcomes. Graefes Arch Clin Exp Ophthalmol 2009;247:325-30.
    • (2009) Graefes Arch Clin Exp Ophthalmol , vol.247 , pp. 325-330
    • Inoue, M.1    Watanabe, Y.2    Arakawa, A.3    Sato, S.4    Kobayashi, S.5    Kadonosono, K.6
  • 21
    • 43249100492 scopus 로고    scopus 로고
    • Correlation between foveal structure and visual outcome following macular hole surgery: A spectral optical coherence tomography study
    • Michalewska Z, Michalewski J, Cisiecki S, Adelman R, Nawrocki J. Correlation between foveal structure and visual outcome following macular hole surgery: a spectral optical coherence tomography study. Graefes Arch Clin Exp Ophthalmol 2008;246:823-30.
    • (2008) Graefes Arch Clin Exp Ophthalmol , vol.246 , pp. 823-830
    • Michalewska, Z.1    Michalewski, J.2    Cisiecki, S.3    Adelman, R.4    Nawrocki, J.5
  • 22
    • 77949898577 scopus 로고    scopus 로고
    • Photoreceptor inner/outer segment defect imaging by spectral domain OCT and visual prognosis after macular hole surgery
    • Oh J, Smiddy WE, Flynn HW, Jr., Gregori G, Lujan B. Photorecep-tor inner/outer segment defect imaging by spectral domain OCT and visual prognosis after macular hole surgery. Invest Ophthalmol Vis Sci 2010;51:1651-8.
    • (2010) Invest Ophthalmol Vis Sci , vol.51 , pp. 1651-1658
    • Oh, J.1    Smiddy, W.E.2    Flynn Jr., H.W.3    Gregori, G.4    Lujan, B.5
  • 24
    • 46149121499 scopus 로고    scopus 로고
    • Ultrastructural correlation of spectral-domain optical coherence to-mographic findings in vitreomacular traction syndrome
    • Chang LK, Fine HF, Spaide RF, Koizumi H, Grossniklaus HE. Ultrastructural correlation of spectral-domain optical coherence to-mographic findings in vitreomacular traction syndrome. Am J Oph-thalmol 2008;146:121-7.
    • (2008) Am J Oph-thalmol , vol.146 , pp. 121-127
    • Chang, L.K.1    Fine, H.F.2    Spaide, R.F.3    Koizumi, H.4    Grossniklaus, H.E.5
  • 25
    • 39149134265 scopus 로고    scopus 로고
    • Three-dimensional evaluation of vitreomacular traction and epiretinal membrane using spectral-domain optical coherence tomography
    • Koizumi H, Spaide RF, Fisher YL, Freund KB, Klancnik JM, Jr., Yannuzzi LA. Three-dimensional evaluation of vitreomacular traction and epiretinal membrane using spectral-domain optical coherence tomography. Am J Ophthalmol 2008;145:509-17.
    • (2008) Am J Ophthalmol , vol.145 , pp. 509-517
    • Koizumi, H.1    Spaide, R.F.2    Fisher, Y.L.3    Freund, K.B.4    Klancnik Jr., J.M.5    Yannuzzi, L.A.6
  • 26
    • 47549084227 scopus 로고    scopus 로고
    • The role of abnormal vitreomacular adhesion in age-related macular degeneration: Spectral optical coherence tomography and surgical results
    • Mojana F, Cheng L, Bartsch DU, Silva GA, Kozak I, Nigam N, Freeman WR. The role of abnormal vitreomacular adhesion in age-related macular degeneration: spectral optical coherence tomography and surgical results. Am J Ophthalmol 2008;146:218-27.
    • (2008) Am J Ophthalmol , vol.146 , pp. 218-227
    • Mojana, F.1    Cheng, L.2    Bartsch, D.U.3    Silva, G.A.4    Kozak, I.5    Nigam, N.6    Freeman, W.R.7
  • 27
    • 0034960797 scopus 로고    scopus 로고
    • Postsurgical evaluation of idiopathic vitreomacular traction syndrome by optical coherence tomography
    • DOI 10.1016/S0002-9394(00)00957-0, PII S0002939400009570
    • Uchino E, Uemura A, Doi N, Ohba N. Postsurgical evaluation of idiopathic vitreomacular traction syndrome by optical coherence tomography. Am J Ophthalmol 2001;132:122-3. (Pubitemid 32600906)
    • (2001) American Journal of Ophthalmology , vol.132 , Issue.1 , pp. 122-123
    • Uchino, E.1    Uemura, A.2    Doi, N.3    Ohba, N.4
  • 28
    • 50249110071 scopus 로고    scopus 로고
    • Morphologic changes in acute central serous chorioretinopathy evaluated by fourier-domain optical coherence tomography
    • Fujimoto H, Gomi F, Wakabayashi T, Sawa M, Tsujikawa M, Tano Y. Morphologic changes in acute central serous chorioretinopathy evaluated by fourier-domain optical coherence tomography. Ophthalmology 2008;115:1494-500.
    • (2008) Ophthalmology , vol.115 , pp. 1494-1500
    • Fujimoto, H.1    Gomi, F.2    Wakabayashi, T.3    Sawa, M.4    Tsujikawa, M.5    Tano, Y.6
  • 30
    • 79961012019 scopus 로고    scopus 로고
    • Optical coherence tomography (OCT) for detection of macular oedema in patients with diabetic retinopathy
    • Virgili G, Menchini F, Murro V, Peluso E, Rosa F, Casazza G. Optical coherence tomography (OCT) for detection of macular oedema in patients with diabetic retinopathy. Cochrane Database Syst Rev 2011(7):CD008081.
    • (2011) Cochrane Database Syst Rev , Issue.7
    • Virgili, G.1    Menchini, F.2    Murro, V.3    Peluso, E.4    Rosa, F.5    Casazza, G.6
  • 31
    • 84862833603 scopus 로고    scopus 로고
    • Computerized macular pathology diagnosis in spectral domain optical coherence tomography scans based on multiscale texture and shape features
    • Liu YY, Ishikawa H, Chen M, Wollstein G, Duker JS, Fujimoto JG, Schuman JS, Rehg JM. Computerized macular pathology diagnosis in spectral domain optical coherence tomography scans based on multiscale texture and shape features. Invest Ophthalmol Vis Sci 2011;52:8316-22.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 8316-8322
    • Liu, Y.Y.1    Ishikawa, H.2    Chen, M.3    Wollstein, G.4    Duker, J.S.5    Fujimoto, J.G.6    Schuman, J.S.7    Rehg, J.M.8
  • 32
    • 23244456347 scopus 로고    scopus 로고
    • Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes
    • DOI 10.1167/iovs.04-1174
    • Budenz DL, Chang RT, Huang X, Knighton RW, Tielsch JM. Re-producibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes. Invest Ophthalmol Vis Sci 2005;46:2440-3. (Pubitemid 43119491)
    • (2005) Investigative Ophthalmology and Visual Science , vol.46 , Issue.7 , pp. 2440-2443
    • Budenz, D.L.1    Chang, R.T.2    Huang, X.3    Knighton, R.W.4    Tielsch, J.M.5
  • 33
    • 77949653292 scopus 로고    scopus 로고
    • The Heidelberg retina tomograph Glaucoma Probability Score: Reproducibility and measurement of progression
    • Strouthidis NG, Demirel S, Asaoka R, Cossio-Zuniga C, Garway-Heath DF. The Heidelberg retina tomograph Glaucoma Probability Score: reproducibility and measurement of progression. Ophthalmology 2010;117:724-9.
    • (2010) Ophthalmology , vol.117 , pp. 724-729
    • Strouthidis, N.G.1    Demirel, S.2    Asaoka, R.3    Cossio-Zuniga, C.4    Garway-Heath, D.F.5
  • 35
    • 33748876059 scopus 로고    scopus 로고
    • Agreement and repeatability for standard automated perimetry and confocal scanning laser ophthalmoscopy in the diagnostic innovations in glaucoma study
    • DOI 10.1016/j.ajo.2006.04.027, PII S0002939406004995
    • Ng D, Zangwill LM, Racette L, Bowd C, Pascual JP, Bourne RR, Boden C, Weinreb RN, Sample PA. Agreement and repeatability for standard automated perimetry and confocal scanning laser ophthal-moscopy in the diagnostic innovations in glaucoma study. Am J Oph-thalmol 2006;142:381-6. (Pubitemid 44691753)
    • (2006) American Journal of Ophthalmology , vol.142 , Issue.3 , pp. 381-386
    • Ng, D.1    Zangwill, L.M.2    Racette, L.3    Bowd, C.4    Pascual, J.P.5    Bourne, R.R.A.6    Boden, C.7    Weinreb, R.N.8    Sample, P.A.9
  • 36
    • 77956023484 scopus 로고    scopus 로고
    • Comparison of repeatability of retinal nerve fiber layer thickness measurement made using the RTVue Fourier-domain optical coherence tomograph and the GDx scanning laser polarimeter with variable or enhanced corneal compensation
    • Garas A, Toth M, Vargha P, Hollo G. Comparison of repeatability of retinal nerve fiber layer thickness measurement made using the RTVue Fourier-domain optical coherence tomograph and the GDx scanning laser polarimeter with variable or enhanced corneal compensation. J Glaucoma 2010;19:412-7.
    • (2010) J Glaucoma , vol.19 , pp. 412-417
    • Garas, A.1    Toth, M.2    Vargha, P.3    Hollo, G.4
  • 37
    • 47749141889 scopus 로고    scopus 로고
    • Retinal nerve fiber layer measurement repeatability in scanning laser polarimetry with enhanced corneal compensation
    • Mai TA, Reus NJ, Lemij HG. Retinal nerve fiber layer measurement repeatability in scanning laser polarimetry with enhanced corneal compensation. J Glaucoma 2008;17:269-74.
    • (2008) J Glaucoma , vol.17 , pp. 269-274
    • Mai, T.A.1    Reus, N.J.2    Lemij, H.G.3
  • 38
    • 80054866174 scopus 로고    scopus 로고
    • Quality and reproducibility of retinal thickness measurements in two spectral-domain optical coherence tomography machines
    • Krebs I, Smretschnig E, Moussa S, Brannath W, Womastek I, Binder S. Quality and reproducibility of retinal thickness measurements in two spectral-domain optical coherence tomography machines. Invest Ophthalmol Vis Sci 2011;52:6925-33.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 6925-6933
    • Krebs, I.1    Smretschnig, E.2    Moussa, S.3    Brannath, W.4    Womastek, I.5    Binder, S.6
  • 39
    • 80051572527 scopus 로고    scopus 로고
    • Reproducibility of retinal nerve fiber layer thickness measurements using the eye tracker and the retest function of Spectralis SD-OCT in glaucomatous and healthy control eyes
    • Langenegger SJ, Funk J, Toteberg-Harms M. Reproducibility of retinal nerve fiber layer thickness measurements using the eye tracker and the retest function of Spectralis SD-OCT in glaucomatous and healthy control eyes. Invest Ophthalmol Vis Sci 2011;52:3338-44.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 3338-3344
    • Langenegger, S.J.1    Funk, J.2    Toteberg-Harms, M.3
  • 40
    • 79951950723 scopus 로고    scopus 로고
    • Reproducibility of peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with cirrus HD-OCT in glaucomatous eyes
    • Mwanza JC, Chang RT, Budenz DL, Durbin MK, Gendy MG, Shi W, Feuer WJ. Reproducibility of peripapillary retinal nerve fiber layer thickness and optic nerve head parameters measured with cirrus HD-OCT in glaucomatous eyes. Invest Ophthalmol Vis Sci 2010; 51:5724-30.
    • (2010) Invest Ophthalmol Vis Sci , vol.51 , pp. 5724-5730
    • Mwanza, J.C.1    Chang, R.T.2    Budenz, D.L.3    Durbin, M.K.4    Gendy, M.G.5    Shi, W.6    Feuer, W.J.7
  • 41
    • 77949658530 scopus 로고    scopus 로고
    • Reproducibility of retinal nerve fiber layer and macular thickness measurement with the RTVue-100 optical coherence tomograph
    • Garas A, Vargha P, Hollo G. Reproducibility of retinal nerve fiber layer and macular thickness measurement with the RTVue-100 optical coherence tomograph. Ophthalmology 2010;117:738-46.
    • (2010) Ophthalmology , vol.117 , pp. 738-746
    • Garas, A.1    Vargha, P.2    Hollo, G.3
  • 42
    • 79956013064 scopus 로고    scopus 로고
    • Reproducibility of retinal thickness measurements in patients with age-related macular degeneration using 3D Fourier-domain optical coherence tomography (OCT) (Topcon 3D-OCT 1000)
    • Menke MN, Dabov S, Knecht P, Sturm V. Reproducibility of retinal thickness measurements in patients with age-related macular degeneration using 3D Fourier-domain optical coherence tomography (OCT) (Topcon 3D-OCT 1000). Acta Ophthalmol 2011;89: 346-51.
    • (2011) Acta Ophthalmol , vol.89 , pp. 346-351
    • Menke, M.N.1    Dabov, S.2    Knecht, P.3    Sturm, V.4
  • 44
    • 84856374427 scopus 로고    scopus 로고
    • Macular ganglion cell-inner plexiform layer: Automated detection and thickness reproducibility with spectral domain-optical coherence tomography in glaucoma
    • Mwanza JC, Oakley JD, Budenz DL, Chang RT, Knight OJ, Feuer WJ. Macular ganglion cell-inner plexiform layer: automated detection and thickness reproducibility with spectral domain-optical coherence tomography in glaucoma. Invest Ophthalmol Vis Sci 2011; 52:8323-9.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 8323-8329
    • Mwanza, J.C.1    Oakley, J.D.2    Budenz, D.L.3    Chang, R.T.4    Knight, O.J.5    Feuer, W.J.6
  • 47
    • 2942618989 scopus 로고    scopus 로고
    • Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma
    • DOI 10.1001/archopht.122.6.827
    • Medeiros FA, Zangwill LM, Bowd C, Weinreb RN. Comparison of the GDx VCC scanning laser polarimeter, HRT II confocal scanning laser ophthalmoscope, and stratus OCT optical coherence tomograph for the detection of glaucoma. Arch Ophthalmol 2004;122: 827-37. (Pubitemid 38736241)
    • (2004) Archives of Ophthalmology , vol.122 , Issue.6 , pp. 827-837
    • Medeiros, F.A.1    Zangwill, L.M.2    Bowd, C.3    Weinreb, R.N.4
  • 49
    • 0031770658 scopus 로고    scopus 로고
    • Identification of early glaucoma cases with the scanning laser ophthalmoscope
    • DOI 10.1016/S0161-6420(98)98047-2
    • Wollstein G, Garway-Heath DF, Hitchings RA. Identification of early glaucoma cases with the scanning laser ophthalmoscope. Ophthalmology 1998;105:1557-63. (Pubitemid 28509784)
    • (1998) Ophthalmology , vol.105 , Issue.8 , pp. 1557-1563
    • Wollstein, G.1    Garway-Heath, D.F.2    Hitchings, R.A.3
  • 52
    • 35548975227 scopus 로고    scopus 로고
    • Diagnostic Accuracy of Scanning Laser Polarimetry with Enhanced versus Variable Corneal Compensation
    • DOI 10.1016/j.ophtha.2007.01.022, PII S0161642007001169
    • Mai TA, Reus NJ, Lemij HG. Diagnostic accuracy of scanning laser polarimetry with enhanced versus variable corneal compensation. Ophthalmology 2007;114:1988-93. (Pubitemid 350016358)
    • (2007) Ophthalmology , vol.114 , Issue.11 , pp. 1988-1993
    • Mai, T.A.1    Reus, N.J.2    Lemij, H.G.3
  • 57
    • 44649097175 scopus 로고    scopus 로고
    • Comparison of HRT-3 glaucoma probability score and subjective stereophotograph assessment for prediction of progression in glaucoma
    • Alencar LM, Bowd C, Weinreb RN, Zangwill LM, Sample PA, Me-deiros FA. Comparison of HRT-3 glaucoma probability score and subjective stereophotograph assessment for prediction of progression in glaucoma. Invest Ophthalmol Vis Sci 2008;49:1898-906.
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 1898-1906
    • Alencar, L.M.1    Bowd, C.2    Weinreb, R.N.3    Zangwill, L.M.4    Sample, P.A.5    Me-Deiros, F.A.6
  • 58
    • 0034792898 scopus 로고    scopus 로고
    • Optic disc and visual field changes in a prospective longitudinal study of patients with glaucoma: Comparison of scanning laser tomography with conventional perimetry and optic disc photography
    • Chauhan BC, McCormick TA, Nicolela MT, LeBlanc RP. Optic disc and visual field changes in a prospective longitudinal study of patients with glaucoma: comparison of scanning laser tomography with conventional perimetry and optic disc photography. Arch Ophthalmol 2001;119:1492-9. (Pubitemid 32963254)
    • (2001) Archives of Ophthalmology , vol.119 , Issue.10 , pp. 1492-1499
    • Chauhan, B.C.1    McCormick, T.A.2    Nicolela, M.T.3    LeBlanc, R.P.4
  • 59
    • 80053338831 scopus 로고    scopus 로고
    • Combining structural and functional measurements to improve detection of glaucoma progression using Bayesian hierarchical models
    • Medeiros FA, Leite MT, Zangwill LM, Weinreb RN. Combining structural and functional measurements to improve detection of glaucoma progression using Bayesian hierarchical models. Invest Ophthalmol Vis Sci 2011;52:5794-803.
    • (2011) Invest Ophthalmol Vis Sci , vol.52 , pp. 5794-5803
    • Medeiros, F.A.1    Leite, M.T.2    Zangwill, L.M.3    Weinreb, R.N.4
  • 61
    • 79961025730 scopus 로고    scopus 로고
    • Evaluation of retinal nerve fiber layer progression in glaucoma a prospective analysis with neuroretinal rim and visual field progression
    • Leung CK, Liu S, Weinreb RN, Lai G, Ye C, Cheung CY, Pang CP, Tse KK, Lam DS. Evaluation of retinal nerve fiber layer progression in glaucoma a prospective analysis with neuroretinal rim and visual field progression. Ophthalmology 2011;118:1551-7.
    • (2011) Ophthalmology , vol.118 , pp. 1551-1557
    • Leung, C.K.1    Liu, S.2    Weinreb, R.N.3    Lai, G.4    Ye, C.5    Cheung, C.Y.6    Pang, C.P.7    Tse, K.K.8    Lam, D.S.9
  • 63
    • 75149159082 scopus 로고    scopus 로고
    • Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography a study on diagnostic agreement with Heidelberg Retinal Tomograph
    • Leung CK, Ye C, Weinreb RN, Cheung CY, Qiu Q, Liu S, Xu G, Lam DS. Retinal nerve fiber layer imaging with spectral-domain optical coherence tomography a study on diagnostic agreement with Heidelberg Retinal Tomograph. Ophthalmology 2010;117:267-74.
    • (2010) Ophthalmology , vol.117 , pp. 267-274
    • Leung, C.K.1    Ye, C.2    Weinreb, R.N.3    Cheung, C.Y.4    Qiu, Q.5    Liu, S.6    Xu, G.7    Lam, D.S.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.