메뉴 건너뛰기




Volumn 21, Issue 3, 2012, Pages 158-168

Characterizing the inflammatory reaction in explanted Medtronic Freestyle stentless porcine aortic bioprosthesis over a 6-year period

Author keywords

Bioprosthetic valves; Freestyle valve; Humoral rejection; Inflammation

Indexed keywords

COMPLEMENT COMPONENT C4D; IMMUNOGLOBULIN G;

EID: 84861096273     PISSN: 10548807     EISSN: 18791336     Source Type: Journal    
DOI: 10.1016/j.carpath.2011.05.003     Document Type: Article
Times cited : (42)

References (19)
  • 1
    • 33746635455 scopus 로고    scopus 로고
    • Is the degeneration of aortic valve bioprostheses similar to that of native aortic valves? Insights into valvular pathology
    • DOI 10.1586/17434440.3.4.453
    • D. Skowasch, M. Steinmetz, G. Nickenig, and G. Bauriedel Is the degeneration of aortic valve bioprostheses similar to that of native aortic valves? Insights into valvular pathology Expert Rev Med Devices 3 4 2006 453 462 (Pubitemid 44144980)
    • (2006) Expert Review of Medical Devices , vol.3 , Issue.4 , pp. 453-462
    • Skowasch, D.1    Steinmetz, M.2    Nickenig, G.3    Bauriedel, G.4
  • 2
    • 33748428221 scopus 로고    scopus 로고
    • Pathology of infectious and inflammatory diseases in prosthetic heart valves
    • DOI 10.1016/j.carpath.2006.05.002, PII S1054880706000688
    • A. Jegatheeswaran, and J. Butany Pathology of infectious and inflammatory diseases in prosthetic heart valves Cardiovasc Pathol 15 5 2006 252 255 (Pubitemid 44345238)
    • (2006) Cardiovascular Pathology , vol.15 , Issue.5 , pp. 252-255
    • Jegatheeswaran, A.1    Butany, J.2
  • 3
    • 54049158043 scopus 로고    scopus 로고
    • Stentless valves versus stented bioprostheses at the aortic position: Midterm results
    • S. Narang, D.K. Satsangi, A. Banerjee, and M.A. Geelani Stentless valves versus stented bioprostheses at the aortic position: midterm results J Thorac Cardiovasc Surg 136 4 2008 943 947
    • (2008) J Thorac Cardiovasc Surg , vol.136 , Issue.4 , pp. 943-947
    • Narang, S.1    Satsangi, D.K.2    Banerjee, A.3    Geelani, M.A.4
  • 5
    • 22544462790 scopus 로고    scopus 로고
    • Ten-year outcome after aortic valve replacement with the freestyle stentless bioprosthesis
    • [discussion 486-7. PubMed PMID: 16039189]
    • Bach DS, Kon ND, Dumesnil JG, Sintek CF, and Doty DB Ten-year outcome after aortic valve replacement with the freestyle stentless bioprosthesis Ann Thorac Surg 80 2 2005 480 486 [discussion 486-7. PubMed PMID: 16039189]
    • (2005) Ann Thorac Surg , vol.80 , Issue.2 , pp. 480-486
    • Bach, D.S.1    Kon, N.D.2    Dumesnil, J.G.3    Sintek, C.F.4    Doty, D.B.5
  • 6
    • 0036260278 scopus 로고    scopus 로고
    • Eight-year results of aortic root replacement with the freestyle stentless porcine aortic root bioprosthesis
    • DOI 10.1016/S0003-4975(02)03575-0, PII S0003497502035750
    • Kon ND, Riley RD, Adair SM, Kitzman DW, and Cordell AR Eight-year results of aortic root replacement with the freestyle stentless porcine aortic root bioprosthesis Ann Thorac Surg 73 6 2002 1817 1821 [discussion 1821. PubMed PMID: 12078775] (Pubitemid 34596723)
    • (2002) Annals of Thoracic Surgery , vol.73 , Issue.6 , pp. 1817-1821
    • Kon, N.D.1    Riley, R.D.2    Adair, S.M.3    Kitzman, D.W.4    Cordell, A.R.5
  • 7
    • 0036797557 scopus 로고    scopus 로고
    • Impact of implant technique following freestyle stentless aortic valve replacement
    • DOI 10.1016/S0003-4975(02)03832-8, PII S0003497502038328
    • Bach DS, Cartier PC, Kon ND, Johnson KG, Deeb GM, and Doty DB Impact of implant technique following freestyle stentless aortic valve replacement Ann Thorac Surg 74 4 2002 1107 1113 [discussion 1113-4] (Pubitemid 35176727)
    • (2002) Annals of Thoracic Surgery , vol.74 , Issue.4 , pp. 1107-1113
    • Bach, D.S.1    Cartier, P.C.2    Kon, N.D.3    Johnson, K.G.4    Deeb, G.M.5    Doty, D.B.6
  • 9
    • 0023227064 scopus 로고
    • Causes of failure and pathologic findings in surgically removed Ionescu-Shiley standard bovine pericardial heart valve bioprostheses: Emphasis on progressive structural deterioration
    • F.J. Schoen, J. Fernandez, L. Gonzalez-Lavin, and A. Cernaianu Causes of failure and pathologic findings in surgically removed Ionescu-Shiley standard bovine pericardial heart valve bioprostheses: emphasis on progressive structural deterioration Circulation 76 3 1987 618 627 (Pubitemid 17124995)
    • (1987) Circulation , vol.76 , Issue.3 , pp. 618-627
    • Schoen, F.J.1    Fernandez, J.2    Gonzalez-Lavin, L.3    Cernaianu, A.4
  • 10
    • 0019670403 scopus 로고
    • Structure and classification of cuspal tears and perforations in porcine bioprosthetic cardiac valves implanted in patients
    • DOI 10.1016/0002-9149(81)90145-4
    • T. Ishihara, V.J. Ferrans, S.W. Boyce, M. Jones, and W.C. Roberts Structure and classification of cuspal tears and perforations in porcine bioprosthetic cardiac valves implanted in patients Am J Cardiol 48 4 1981 665 678 (Pubitemid 12002805)
    • (1981) American Journal of Cardiology , vol.48 , Issue.4 , pp. 665-678
    • Ishihara, T.1    Ferrans, V.J.2    Boyce, S.W.3
  • 11
    • 33746209047 scopus 로고    scopus 로고
    • Structural deterioration of the Freestyle aortic valve: Mode of presentation and mechanisms
    • DOI 10.1016/j.jtcvs.2006.03.056, PII S0022522306007343
    • S. Mohammadi, R. Baillot, P. Voisine, P. Mathieu, and F. Dagenais Structural deterioration of the Freestyle aortic valve: mode of presentation and mechanisms J Thorac Cardiovasc Surg 132 2 2006 401 406 (Pubitemid 44092866)
    • (2006) Journal of Thoracic and Cardiovascular Surgery , vol.132 , Issue.2 , pp. 401-406
    • Mohammadi, S.1    Baillot, R.2    Voisine, P.3    Mathieu, P.4    Dagenais, F.5
  • 13
    • 21044437380 scopus 로고    scopus 로고
    • Spectrum of calcific aortic valve disease: Pathogenesis, disease progression, and treatment strategies
    • DOI 10.1161/CIRCULATIONAHA.104.486738
    • R.V. Freeman, and C.M. Otto Spectrum of calcific aortic valve disease: pathogenesis, disease progression, and treatment strategies Circulation 111 24 2005 3316 3326 (Pubitemid 40875006)
    • (2005) Circulation , vol.111 , Issue.24 , pp. 3316-3326
    • Freeman, R.V.1    Otto, C.M.2
  • 14
    • 0033814676 scopus 로고    scopus 로고
    • Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: Final report of the Veterans Affairs randomized trial
    • K. Hammermeister, G.K. Sethi, W.G. Henderson, F.L. Grover, C. Oprian, and S.H. Rahimtoola Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: final report of the Veterans Affairs randomized trial J Am Coll Cardiol 36 4 2000 1152 1158
    • (2000) J Am Coll Cardiol , vol.36 , Issue.4 , pp. 1152-1158
    • Hammermeister, K.1    Sethi, G.K.2    Henderson, W.G.3    Grover, F.L.4    Oprian, C.5    Rahimtoola, S.H.6
  • 16
    • 0021831273 scopus 로고
    • Anatomic analysis of removed prosthetic heart valves: Causes of failure of 33 mechanical valves and 58 bioprostheses, 1980 to 1983
    • DOI 10.1016/S0046-8177(85)80103-9
    • F.J. Schoen, and C.E. Hobson Anatomic analysis of removed prosthetic heart valves: causes of failure of 33 mechanical valves and 58 bioprostheses, 1980 to 1983 Hum Pathol 16 6 1985 549 559 (Pubitemid 15049628)
    • (1985) Human Pathology , vol.16 , Issue.6 , pp. 549-559
    • Schoen, F.J.1    Hobson, C.E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.