메뉴 건너뛰기




Volumn 1, Issue 7, 2009, Pages 143-149

Identification of photovoltaic array model parameters by robust linear regression methods

Author keywords

Models and simulation of renewable energy sources; Photovoltaic array; Statistics

Indexed keywords


EID: 84861034662     PISSN: None     EISSN: 2172038X     Source Type: Journal    
DOI: 10.24084/repqj07.268     Document Type: Article
Times cited : (28)

References (15)
  • 1
    • 33745727042 scopus 로고    scopus 로고
    • PSIM Circuit-Oriented Simulator Model for the Nonlinear Photovoltaic Sources
    • Apr
    • M. Veerachary, “PSIM Circuit-Oriented Simulator Model for the Nonlinear Photovoltaic Sources”, IEEE Trans. on Aerospace and Electron.Sys., Vol.42, no.2, Apr. 2006, pp.735-740.
    • (2006) IEEE Trans. on Aerospace and Electron.Sys , vol.42 , Issue.2 , pp. 735-740
    • Veerachary, M.1
  • 2
    • 0032629423 scopus 로고    scopus 로고
    • Development of a photovoltaic array model for use in power electronics simulation studies
    • Mar
    • J.A. Gow, C.D. Manning, “Development of a photovoltaic array model for use in power electronics simulation studies”, IEE Proc. Electronic Power Applications, Vol.146, No. 2, Mar. 1999, pp.193 – 200.
    • (1999) IEE Proc. Electronic Power Applications , vol.146 , Issue.2 , pp. 193-200
    • Gow, J.A.1    Manning, C.D.2
  • 6
    • 85073358755 scopus 로고    scopus 로고
    • E4350B, E4351BSept, Agilent Part No. 5962-8206. [Online]
    • Agilent application specific dc power supplies, Operating guide for solar array simulators Agilent models E4350B, E4351B, Sept. 2004, Agilent Part No. 5962-8206. [Online] Available: www.agilent.com/find/power.
    • (2004) Operating Guide for Solar Array Simulators Agilent Models
  • 10
    • 27944473563 scopus 로고    scopus 로고
    • Electromagnetic compatibility characterisation of the DC side in a low power photovoltaic plant
    • 8-10 Dec
    • M.C Di Piazza, C Serporta.; G. Tine, G. Vitale, “Electromagnetic compatibility characterisation of the DC side in a low power photovoltaic plant”, in Proc. IEEE Intern. Conf. on Industr.Technology, vol. 2, 8-10 Dec. 2004, pp.672-677.
    • (2004) Proc. IEEE Intern. Conf. on Industr.Technology , vol.2 , pp. 672-677
    • Di Piazza, M.C.1    Serporta, C.2    Tine, G.3    Vitale, G.4
  • 12
    • 33845792219 scopus 로고    scopus 로고
    • Photovoltaic module thermal/wind performance: Long-Term Monitoring and Model Development For Energy Rating
    • G. TamizhMani, L. Ji, Y. Tang, L. Petacci, C. Osterwald, “Photovoltaic module thermal/wind performance: Long-Term Monitoring and Model Development For Energy Rating”, NCPV and Solar Program Review Meeting, 2003 pp.936-939.
    • (2003) NCPV and Solar Program Review Meeting , pp. 936-939
    • Tamizhmani, G.1    Ji, L.2    Tang, Y.3    Petacci, L.4    Osterwald, C.5
  • 15
    • 33845186097 scopus 로고
    • A Note on Computing Robust Regression Estimates via Iteratively Reweighted Least Squares
    • Street, J.O., R.J. Carroll, and D. Ruppert (1988), "A Note on Computing Robust Regression Estimates via Iteratively Reweighted Least Squares," The American Statistician, 42, pp.152-154.
    • (1988) The American Statistician , vol.42 , pp. 152-154
    • Street, J.O.1    Carroll, R.J.2    Ruppert, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.