-
2
-
-
84255198671
-
Morphological and functional evaluation of the bioresorption of the bioresorbable everolimus-eluting vascular scaffold using ivus, echogenicity and vasomotion testing at two year follow-up: A patient level insight into the absorb a clinical trial
-
Jan 7. [Epub ahead of print]
-
Sarno G, Bruining N, Onuma Y, Garg S, Brugaletta S, De Winter S, Regar E, Thuesen L, Dudek D, Veldhof S, Dorange C, Garcia-Garcia HM, Ormiston JA, Serruys PW. Morphological and functional evaluation of the bioresorption of the bioresorbable everolimus-eluting vascular scaffold using IVUS, echogenicity and vasomotion testing at two year follow-up: a patient level insight into the ABSORB A clinical trial. Int J Cardiovasc Imaging. 2011 Jan 7. [Epub ahead of print].
-
(2011)
Int J Cardiovasc Imaging
-
-
Sarno, G.1
Bruining, N.2
Onuma, Y.3
Garg, S.4
Brugaletta, S.5
De Winter, S.6
Regar, E.7
Thuesen, L.8
Dudek, D.9
Veldhof, S.10
Dorange, C.11
Garcia-Garcia, H.M.12
Ormiston, J.A.13
Serruys, P.W.14
-
3
-
-
79952057270
-
Bioresorbable scaffold: The advent of a new era in percutaneous coronary and peripheral revascularization?
-
Onuma Y, Serruys PW. Bioresorbable scaffold: the advent of a new era in percutaneous coronary and peripheral revascularization? Circulation. 2011;123:779-797.
-
(2011)
Circulation
, vol.123
, pp. 779-797
-
-
Onuma, Y.1
Serruys, P.W.2
-
4
-
-
33748167399
-
Drug-eluting bioresorbable stents for various applications
-
DOI 10.1146/annurev.bioeng.8.013106.151418
-
Zilberman M, Eberhart RC. Drug-eluting bioresorbable stents for various applications. Annu Rev Biomed Eng. 2006;8:153-180. (Pubitemid 44314815)
-
(2006)
Annual Review of Biomedical Engineering
, vol.8
, pp. 153-180
-
-
Zilberman, M.1
Eberhart, R.C.2
-
5
-
-
77956159301
-
Engineering a bioresorbable stent: Reva programme update
-
Pollman M. Engineering a bioresorbable stent: REVA Programme update. EuroIntervention Supplement. 2009;5:F54-F57.
-
(2009)
EuroIntervention Supplement
, vol.5
-
-
Pollman, M.1
-
6
-
-
28244463918
-
Advances in the development of coronary stents
-
Zeltinger J, Schmid E, Brandom D, Bolikal D, Pesnell A, Kohn J. Advances in the development of coronary stents. Biomaterials Forum. 2004;26:8 -9, 24.
-
(2004)
Biomaterials Forum.
, vol.26
, Issue.8-9
, pp. 24
-
-
Zeltinger, J.1
Schmid, E.2
Brandom, D.3
Bolikal, D.4
Pesnell, A.5
Kohn, J.6
-
8
-
-
84860871789
-
Is the domestic crossbred swine an appropriate model for drug-eluting stent testing?
-
Touchard AG, Poff BC, Russell ME, Schwartz RS. Is the domestic crossbred swine an appropriate model for drug-eluting stent testing? Am J Cardiol 2003;92:182L.
-
(2003)
Am J Cardiol
, vol.92
-
-
Touchard, A.G.1
Poff, B.C.2
Russell, M.E.3
Schwartz, R.S.4
-
9
-
-
0031925121
-
Experimental intracoronary stenting: Comprehensive experience in a porcine model
-
Vollmar B, Bay W, Ozbek C, Heib KD, Menger MD, Schieffer HJ. Experimental intracoronary stenting: comprehensive experience in a porcine model. Lab Anim. 1998;32:191-199. (Pubitemid 28185302)
-
(1998)
Laboratory Animals
, vol.32
, Issue.2
, pp. 191-199
-
-
Vollmar, B.1
Bay, W.2
Ozbek, C.3
Heib, K.-D.4
Menger, M.D.5
Schieffer, H.-J.6
-
10
-
-
84860845564
-
Biodegradable scaffolds: An update and work-in-progress
-
MD. Available at
-
Tamai H. Biodegradable scaffolds: an update and work-in-progress. Angioplasty Summit MD. Available at: http://www.summitmd.com/pdf/pdf/031031- lecture.pdf, 2011.
-
(2011)
Angioplasty Summit
-
-
Tamai, H.1
-
11
-
-
61849110613
-
A bioabsorbable everolimus-eluting coronary stent system (absorb): 2-year outcomes and results from multiple imaging methods
-
Serruys PW, Ormiston JA, Onuma Y, Regar E, Gonzalo N, Garcia-Garcia HM, Nieman K, Bruining N, Dorange C, Miquel-Hebert K, Veldhof S, Webster M, Thuesen L, Dudek D. A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods. Lancet. 2009;373:897-910.
-
(2009)
Lancet
, vol.373
, pp. 897-910
-
-
Serruys, P.W.1
Ormiston, J.A.2
Onuma, Y.3
Regar, E.4
Gonzalo, N.5
Garcia-Garcia, H.M.6
Nieman, K.7
Bruining, N.8
Dorange, C.9
Miquel-Hebert, K.10
Veldhof, S.11
Webster, M.12
Thuesen, L.13
Dudek, D.14
-
12
-
-
79952044287
-
Design principles and performance of bioresorbable polymeric vascular scaffolds
-
Oberhauser J, Hossainy S, Rapoza R. Design principles and performance of bioresorbable polymeric vascular scaffolds. EuroIntervention Supplement. 2009;5:F15-F22.
-
(2009)
EuroIntervention Supplement
, vol.5
-
-
Oberhauser, J.1
Hossainy, S.2
Rapoza, R.3
-
13
-
-
0345275858
-
The porcine coronary model of in-stent restenosis: Current status in the era of drug-eluting stents
-
DOI 10.1002/ccd.10705
-
Lowe HC, Schwartz RS, Mac Neill BD, Jang IK, Hayase M, Rogers C, Oesterle SN. The porcine coronary model of in-stent restenosis: current status in the era of drug-eluting stents. Catheter Cardiovasc Interv. 2003;60:515-523. (Pubitemid 37466762)
-
(2003)
Catheterization and Cardiovascular Interventions
, vol.60
, Issue.4
, pp. 515-523
-
-
Lowe, H.C.1
Schwartz, R.S.2
Mac Neill, B.D.3
Jang, I.-K.4
Hayase, M.5
Rogers, C.6
Oesterle, S.N.7
-
14
-
-
78650171486
-
Intracoronary optical coherence tomography and histology at 1 month and 2, 3, and 4 years after implantation of everolimuseluting bioresorbable vascular scaffolds in a porcine coronary artery model: An attempt to decipher the human optical coherence tomography images in the absorb trial
-
Onuma Y, Serruys PW, Perkins LE, Okamura T, Gonzalo N, Garcia-Garcia HM, Regar E, Kamberi M, Powers JC, Rapoza R, van Beusekom H, van der Giessen W, Virmani R. Intracoronary optical coherence tomography and histology at 1 month and 2, 3, and 4 years after implantation of everolimuseluting bioresorbable vascular scaffolds in a porcine coronary artery model: an attempt to decipher the human optical coherence tomography images in the ABSORB trial. Circulation. 2010;122:2288-2300.
-
(2010)
Circulation
, vol.122
, pp. 2288-2300
-
-
Onuma, Y.1
Serruys, P.W.2
Perkins, L.E.3
Okamura, T.4
Gonzalo, N.5
Garcia-Garcia, H.M.6
Regar, E.7
Kamberi, M.8
Powers, J.C.9
Rapoza, R.10
Van Beusekom, H.11
Van Der Giessen, W.12
Virmani, R.13
-
15
-
-
0034580276
-
Synthetic biodegradable polymers as orthopaedic devices
-
Middleton JC, Tipton AJ. Synthetic biodegradable polymers as orthopaedic devices. Biomaterials. 2000;21:2335-2346.
-
(2000)
Biomaterials
, vol.21
, pp. 2335-2346
-
-
Middleton, J.C.1
Tipton, A.J.2
-
16
-
-
67650067085
-
Transmural pressure and axial loading interactively regulate arterial remodeling ex vivo
-
Lawrence AR, Gooch KJ. Transmural pressure and axial loading interactively regulate arterial remodeling ex vivo. Am J Physiol Heart Circ Physiol. 2009;297:H475-H484.
-
(2009)
Am J Physiol Heart Circ Physiol
, vol.297
-
-
Lawrence, A.R.1
Gooch, K.J.2
-
18
-
-
0343729980
-
Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events
-
DOI 10.1016/S0735-1097(00)00570-2, PII S0735109700005702
-
Gyongyosi M, Yang P, Khorsand A, Glogar D. Longitudinal straightening effect of stents is an additional predictor for major adverse cardiac events. Austrian Wiktor Stent Study Group and European Paragon Stent Investigators. J Am Coll Cardiol. 2000;35:1580-1589. (Pubitemid 30307504)
-
(2000)
Journal of the American College of Cardiology
, vol.35
, Issue.6
, pp. 1580-1589
-
-
Gyongyosi, M.1
Yang, P.2
Khorsand, A.3
Glogar, D.4
-
19
-
-
0034308346
-
Coronary stent implantation changes 3-D vessel geometry and 3-D shear stress distribution
-
DOI 10.1016/S0021-9290(00)00066-X, PII S002192900000066X
-
Wentzel JJ, Whelan DM, van der Giessen WJ, van Beusekom HM, Andhyiswara I, Serruys PW, Slager CJ, Krams R. Coronary stent implantation changes 3-D vessel geometry and 3-D shear stress distribution. J Biomech. 2000;33:1287-1295. (Pubitemid 30427325)
-
(2000)
Journal of Biomechanics
, vol.33
, Issue.10
, pp. 1287-1295
-
-
Wentzel, J.J.1
M. Whelan, D.2
Van Der Giessen, W.J.3
Van Beusekom, H.M.M.4
Andhyiswara, I.5
Serruys, P.W.6
Slager, C.J.7
Krams, R.8
-
20
-
-
0032192119
-
Long-term endothelial dysfunction is more pronounced after stenting than after balloon angioplasty in porcine coronary arteries
-
DOI 10.1016/S0735-1097(98)00348-9, PII S0735109798003489
-
van Beusekom HM, Whelan DM, Hofma SH, Krabbendam SC, van Hinsbergh VW, Verdouw PD, van der Giessen WJ. Long-term endothelial dysfunction is more pronounced after stenting than after balloon angioplasty in porcine coronary arteries. J Am Coll Cardiol. 1998;32: 1109-1117. (Pubitemid 28459607)
-
(1998)
Journal of the American College of Cardiology
, vol.32
, Issue.4
, pp. 1109-1117
-
-
Van Beusekom, H.M.M.1
Whelan, D.M.2
Hofma, S.H.3
Krabbendam, S.C.4
Van Hinsbergh, V.W.M.5
Verdouw, P.D.6
Van Der Giessen, W.J.7
-
21
-
-
0033571509
-
Long-term endothelial dysfunction after coronary artery stenting
-
Caramori PR, Lima VC, Seidelin PH, Newton GE, Parker JD, Adelman AG. Long-term endothelial dysfunction after coronary artery stenting. J Am Coll Cardiol. 1999;34:1675-1679.
-
(1999)
J Am Coll Cardiol
, vol.34
, pp. 1675-1679
-
-
Caramori, P.R.1
Lima, V.C.2
Seidelin, P.H.3
Newton, G.E.4
Parker, J.D.5
Adelman, A.G.6
-
22
-
-
0028970406
-
Flow instabilities induced by coronary artery stents: Assessment with an in vitro pulse duplicator
-
DOI 10.1016/0021-9290(95)80003-4
-
Peacock J, Hankins S, Jones T, Lutz R. Flow instabilities induced by coronary artery stents: assessment with an in vitro pulse duplicator. J Biomech. 1995;28:17-26. (Pubitemid 24343728)
-
(1995)
Journal of Biomechanics
, vol.28
, Issue.1
, pp. 17-26
-
-
Peacock, J.1
Hankins, S.2
Jones, T.3
Lutz, R.4
-
23
-
-
33745451009
-
Cardiology is flow
-
DOI 10.1161/CIRCULATIONAHA.106.632687, PII 0000301720060613000004
-
Richter Y, Edelman ER. Cardiology is flow. Circulation. 2006;113: 2679-2682. (Pubitemid 43947984)
-
(2006)
Circulation
, vol.113
, Issue.23
, pp. 2679-2682
-
-
Richter, Y.1
Edelman, E.R.2
-
24
-
-
0033485806
-
Hemodynamic shear stress and its role in atherosclerosis
-
Malek AM, Alper SL, Izumo S. Hemodynamic shear stress and its role in atherosclerosis. JAMA. 1999;282:2035-2042.
-
(1999)
JAMA
, vol.282
, pp. 2035-2042
-
-
Malek, A.M.1
Alper, S.L.2
Izumo, S.3
|