메뉴 건너뛰기




Volumn 60, Issue 3, 2012, Pages 140-144

Experimental study on effective application of fibrin glue

Author keywords

Cardiac surgery; Fibrin glue; Fibrin sealant; Hemostasis; Rubbing method

Indexed keywords

FIBRIN GLUE; FIBRINOGEN; THROMBIN;

EID: 84860769637     PISSN: 18636705     EISSN: 18636713     Source Type: Journal    
DOI: 10.1007/s11748-011-0864-3     Document Type: Article
Times cited : (10)

References (12)
  • 2
    • 0036021724 scopus 로고    scopus 로고
    • Significant merits of a fibrin sealant in the presence of coagulopathy following paediatric cardiac surgery: Randomised controlled trial
    • DOI 10.1016/S1010-7940(02)00271-3, PII S1010794002002713
    • Codispoti M, Mankad PS. Significant merit of a fibrin sealant in the presence of coagulopathy following paediatric cardiac surgery: randomized controlled trial. Eur J Cardiothorac Surg 2002;22:200-5. (Pubitemid 34831856)
    • (2002) European Journal of Cardio-thoracic Surgery , vol.22 , Issue.2 , pp. 200-205
    • Codispoti, M.1    Mankad, P.S.2
  • 6
    • 0029128568 scopus 로고
    • Fibrin sealant reduces suture line bleeding during carotid endarterectomy: A randomized trial
    • Miline AA, Murphy WG, Reading SJ, Ruckley CV. Fibrin sealant reduces suture line bleeding during carotid endarterectomy: a randomized trial. Eur J Vasc Endovasc Surg 1995;10: 91-4.
    • (1995) Eur J Vasc Endovasc Surg , vol.10 , pp. 91-94
    • Miline, A.A.1    Murphy, W.G.2    Reading, S.J.3    Ruckley, C.V.4
  • 7
    • 0141988933 scopus 로고    scopus 로고
    • Prospective randomized multicenter trial of fibrin sealant versus thrombin-soaked gelatin sponge for suture- or needle-hole bleeding from polytetrafluoroethylene femoral artery grafts
    • DOI 10.1016/S0741-5214(03)00474-9
    • Taylor LM Jr, Mueller-Velten G, Koslow A, Hunter G, Naslund T, Kliner R. Prospective randomized multicenter trial of fibrin sealant versus thrombin-soaked gelatin sponge for for suture- or needle-hole bleeding from polytetrafluoroethylene femoral artery grafts. J Vasc Surg 2003;38:766-71. (Pubitemid 37254806)
    • (2003) Journal of Vascular Surgery , vol.38 , Issue.4 , pp. 766-771
    • Taylor Jr., L.M.1    Mueller-Velten, G.2    Koslow, A.3    Hunter, G.4    Naslund, T.5    Kline, R.6
  • 8
    • 0034973264 scopus 로고    scopus 로고
    • New technique for application of fibrin sealant: Rubbing method devised to prevent cerebrospinal fluid leakage from dura mater sites repaired with expanded polytetrafluoroethylene surgical membranes
    • Nakajima S, Fukuda T, Hasue M, Sengoku Y, Haraoka J, Uchida T. New technique for application of fibrin sealant: rubbing method devised to prevent cerebrospinal fluid leakage from dura mater sites repaired with expanded polytetrafluoroethylene surgical membrane. Neurosurgery 2001;49:117-23. (Pubitemid 32552589)
    • (2001) Neurosurgery , vol.49 , Issue.1 , pp. 117-123
    • Nakajima, S.1    Fukuda, T.2    Hasue, M.3    Sengoku, Y.4    Haraoka, J.5    Uchida, T.6
  • 10
    • 39149102466 scopus 로고    scopus 로고
    • The optimal technique for combined application of fibrin sealant and bioabsorbable felt against alveolar air leakage
    • Itano H. The optimal technique for combined application of fibrin sealant and bioabsorbable felt against alveolar air leakage. Eur J Cardiothorac Surg 2008;33:457-60.
    • (2008) Eur J Cardiothorac Surg , vol.33 , pp. 457-460
    • Itano, H.1
  • 12
    • 0027989472 scopus 로고
    • Important factors influencing the strength of autologous fibrin glue; The fibrin concentration and reaction time - comparison of strength with commercial fibrin glue
    • Kjaerdard HK, Weis-Fogh US. Important factors influencing the strength of autologous fibrin glue: the fibrin concentration and reaction time-comparison of strength with commercial fibrin glue. Eur Surg Res 1994;26:273-6. (Pubitemid 24301886)
    • (1994) European Surgical Research , vol.26 , Issue.5 , pp. 273-276
    • Kjaergad, H.K.1    Weis-Fogh, U.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.