메뉴 건너뛰기




Volumn 43, Issue 6, 2012, Pages 946-949

Monoblock hemiarthroplasties for femoral neck fractures - A part of orthopaedic history? Analysis of national registration of hemiarthroplasties 2005-2009

Author keywords

Arthroplasty; Complications; Hip fractures; National register; Re operations

Indexed keywords

AGED; ARTICLE; CONTROLLED STUDY; FEMALE; FEMUR NECK FRACTURE; HIP HEMIARTHROPLASTY; HUMAN; MAJOR CLINICAL STUDY; MALE; PERIPROSTHETIC FRACTURE; PRIORITY JOURNAL; PROSTHESIS FAILURE; PROSTHESIS INFECTION; REOPERATION; SURGICAL RISK;

EID: 84860751899     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/j.injury.2011.11.022     Document Type: Article
Times cited : (23)

References (16)
  • 2
    • 0001112498 scopus 로고
    • Metal hip joint; A new self-locking vitallium prosthesis
    • November
    • A.T. Moore Metal hip joint; a new self-locking vitallium prosthesis South Med J 45 November (11) 1952 1015 1019
    • (1952) South Med J , vol.45 , Issue.11 , pp. 1015-1019
    • Moore, A.T.1
  • 3
    • 0025981162 scopus 로고
    • Bipolar hemiarthroplasty for subcapital fracture of the femoral neck. A prospective randomised trial of cemented Thompson and uncemented Moore stems
    • R.J. Emery, N.S. Broughton, K. Desai, C.J. Bulstrode, and T.L. Thomas Bipolar hemiarthroplasty for subcapital fracture of the femoral neck. A prospective randomised trial of cemented Thompson and uncemented Moore stems J Bone Joint Surg [Br] 73 2 1991 322 324
    • (1991) J Bone Joint Surg [Br] , vol.73 , Issue.2 , pp. 322-324
    • Emery, R.J.1    Broughton, N.S.2    Desai, K.3    Bulstrode, C.J.4    Thomas, T.L.5
  • 4
    • 0025801560 scopus 로고
    • Quality of life after primary hemiarthroplasty for femoral neck fracture. 6-Year follow-up of 185 patients
    • P. Jalovaara, and H. Virkkunen Quality of life after primary hemiarthroplasty for femoral neck fracture. 6-Year follow-up of 185 patients Acta Orthop Scand 62 3 1991 208 217
    • (1991) Acta Orthop Scand , vol.62 , Issue.3 , pp. 208-217
    • Jalovaara, P.1    Virkkunen, H.2
  • 5
    • 0020570870 scopus 로고
    • Moore prosthesis in the treatment of fresh femoral neck fractures. A critical review with special attention to secondary acetabular degeneration
    • May
    • H. Kofoed, and J. Kofod Moore prosthesis in the treatment of fresh femoral neck fractures. A critical review with special attention to secondary acetabular degeneration Injury 14 May (6) 1983 531 540
    • (1983) Injury , vol.14 , Issue.6 , pp. 531-540
    • Kofoed, H.1    Kofod, J.2
  • 6
    • 0034538341 scopus 로고    scopus 로고
    • Internal fixation versus hemiarthroplasty versus total hip arthroplasty for displaced subcapital fractures of femur - 13 Year results of a prospective randomised study
    • DOI 10.1016/S0020-1383(00)00125-X, PII S002013830000125X
    • K.J. Ravikumar, and G. Marsh Internal fixation versus hemiarthroplasty versus total hip arthroplasty for displaced subcapital fractures of femur - 13 year results of a prospective randomised study Injury 31 December (10) 2000 793 797 (Pubitemid 32012474)
    • (2000) Injury , vol.31 , Issue.10 , pp. 793-797
    • Ravikumar, K.J.1    Marsh, G.2
  • 8
    • 0036298614 scopus 로고    scopus 로고
    • A survey of the treatment of displaced intracapsular femoral neck fractures in the UK
    • DOI 10.1016/S0020-1383(02)00002-5, PII S0020138302000025
    • P.T. Crossman, R.J. Khan, A. MacDowell, A.C. Gardner, N.S. Reddy, and G.S. Keene A survey of the treatment of displaced intracapsular femoral neck fractures in the UK Injury 33 June (5) 2002 383 386 (Pubitemid 34722607)
    • (2002) Injury , vol.33 , Issue.5 , pp. 383-386
    • Crossman, P.T.1    Khan, R.J.K.2    MacDowell, A.3    Gardner, A.C.4    Reddy, N.S.5    Keene, G.S.6
  • 9
    • 0001620172 scopus 로고
    • Two and a half years' experience with a vitallium intramedullary hip prosthesis
    • June
    • F.R. Thompson Two and a half years' experience with a vitallium intramedullary hip prosthesis J Bone Joint Surg Am 36-A June (3) 1954 489 502
    • (1954) J Bone Joint Surg Am , vol.36 A , Issue.3 , pp. 489-502
    • Thompson, F.R.1
  • 11
    • 0029882899 scopus 로고    scopus 로고
    • Periprosthetic fractures of the femur. An analysis of 93 fractures
    • June
    • R.K. Beals, and S.S. Tower Periprosthetic fractures of the femur. An analysis of 93 fractures Clin Orthop Relat Res June (327) 1996 238 246
    • (1996) Clin Orthop Relat Res , vol.327 , pp. 238-246
    • Beals, R.K.1    Tower, S.S.2
  • 12
    • 0019963675 scopus 로고
    • A retrospective study of Moore and Thompson hemiarthroplasty. A review of 599 surgical cases and an analysis of the technical complications
    • D.C. Kwok, and R.L. Cruess A retrospective study of Moore and Thompson hemiarthroplasty. A review of 599 surgical cases and an analysis of the technical complications Clin Orthop Relat Res 169 September 1982 179 185 (Pubitemid 12021029)
    • (1982) Clinical Orthopaedics and Related Research , vol.169 , pp. 179-185
    • Kwok, D.C.1    Cruess, R.L.2
  • 13
    • 0025285358 scopus 로고
    • Femoral stem fixation in hip replacement. A biomechanical comparison of cementless and cemented prostheses
    • T.W. Phillips, S.S. Messieh, and P.D. McDonald Femoral stem fixation in hip replacement. A biomechanical comparison of cementless and cemented prostheses J Bone Joint Surg Br 72 May (3) 1990 431 434 (Pubitemid 20154152)
    • (1990) Journal of Bone and Joint Surgery - Series B , vol.72 , Issue.3 , pp. 431-434
    • Phillips, T.W.1    Messieh, S.S.2    McDonald, P.D.3
  • 14
    • 33845439875 scopus 로고    scopus 로고
    • Total hip arthroplasty and hemiarthroplasty in mobile, independent patients with a displaced intracapsular fracture of the femoral neck: A randomized, controlled trial
    • DOI 10.2106/JBJS.E.01373
    • R.P. Baker, B. Squires, M.F. Gargan, and G.C. Bannister Total hip arthroplasty and hemiarthroplasty in mobile, independent patients with a displaced intracapsular fracture of the femoral neck. A randomized, controlled trial J Bone Joint Surg Am 88 December (12) 2006 2583 2589 (Pubitemid 44901944)
    • (2006) Journal of Bone and Joint Surgery - Series A , vol.88 , Issue.12 , pp. 2583-2589
    • Baker, R.P.1    Squires, B.2    Gargan, M.F.3    Bannister, G.C.4
  • 15
    • 60349121768 scopus 로고    scopus 로고
    • Swedish hip arthroplasty register
    • Gothenburg, Sweden; [cited 2010 October 29th]. ISBN 978-91-977112-6-5
    • Garellick G, Rogmark C, Herberts P, Kärrholm J. Swedish hip arthroplasty register. Annual report 2009. Gothenburg, Sweden; 2010 [cited 2010 October 29th]. ISBN 978-91-977112-6-5. Available from: www.jru.orthop.gu.se.
    • (2010) Annual Report 2009
    • Garellick, G.1    Rogmark, C.2    Herberts, P.3    Kärrholm, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.