메뉴 건너뛰기




Volumn 13, Issue 2, 2011, Pages 136-141

Allergic contact dermatitis as a reaction to nitinol following transcatheter closure of persistent foramen ovale using Amplatzer occluder - A case report;Alergická kontaktní dermatitida jako reakce na nitinol po katetrizačním uzávěru perzistujícího foramen ovale Amplatzerovým okludérem - Kazuistika

Author keywords

Amplatzer occluder; Contact allergy; Nickel; Nitinol; Titanium

Indexed keywords

ANTIHISTAMINIC AGENT; NITINOL; STEROID;

EID: 84860750502     PISSN: 12123536     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (2)

References (20)
  • 1
    • 70349293782 scopus 로고    scopus 로고
    • Contact sensitivity in the Czech Republic in 1996 and 2006
    • Blackwell Publishing Ltd
    • Dastychová E. Contact sensitivity in the Czech Republic in 1996 and 2006. In: Contact Dermatitis, Blackwell Publishing Ltd, 2008, 58.
    • (2008) Contact Dermatitis , pp. 58
    • Dastychová, E.1
  • 2
    • 74549214406 scopus 로고    scopus 로고
    • Kontaktní přecitlivělost na alergeny Evropské standardnísady
    • Dastychová E, Nečas M. Kontaktní přecitlivělost na alergeny Evropské standardní sady. Česko-slovenská dermatologie 2009, 84: 320-331.
    • (2009) Česko-slovenská Dermatologie , vol.84 , pp. 320-331
    • Dastychová, E.1    Nečas, M.2
  • 3
    • 55249122493 scopus 로고    scopus 로고
    • Suspected association of an allergic reaction with titanium dental implants: A clinical report
    • Egusa H, Ko N, Shimazu T, Yatani H. Suspected association of an allergic reaction with titanium dental implants: a clinical report. J Prosthet Dent 2008, 100: 344-7.
    • (2008) J Prosthet Dent , vol.100 , pp. 344-347
    • Egusa, H.1    Ko, N.2    Shimazu, T.3    Yatani, H.4
  • 6
    • 84858154165 scopus 로고    scopus 로고
    • Is titanium sensitivity associated with allergic reactions in patients with dental implants? A systematic review
    • Mar 17, epub
    • Javed F, Al-Hezaimi K, Almas K, Romanos GE. Is titanium sensitivity associated with allergic reactions in patients with dental implants? A systematic review. Clin Implant Dent Relat Res 2011, Mar 17, epub.
    • (2011) Clin Implant Dent Relat Res
    • Javed, F.1    Al-Hezaimi, K.2    Almas, K.3    Romanos, G.E.4
  • 8
    • 34047211736 scopus 로고    scopus 로고
    • Hypersensitivity to titanium: Clinical and laboratory evidence
    • Mu{combining double acute accent}ller K, Valentine-Thon E. Hypersensitivity to titanium: clinical and laboratory evidence. Neuro Endocrin Lett 2006, 27(Suppl 1): 31-35.
    • (2006) Neuro Endocrin Lett , vol.27 , Issue.SUPPL. 1 , pp. 31-35
    • Muller, K.1    Valentine-Thon, E.2
  • 9
    • 49349089798 scopus 로고    scopus 로고
    • Present status of titanium removable dentures - A review of the literature
    • Ohkubo C, Hanatani S, Hosoi T. Present status of titanium removable dentures - a review of the literature. J Oral Rehabil 2008, 35: 706-14.
    • (2008) J Oral Rehabil , vol.35 , pp. 706-714
    • Ohkubo, C.1    Hanatani, S.2    Hosoi, T.3
  • 10
    • 69249135542 scopus 로고    scopus 로고
    • Unusual presentation of nickel allergy requiring explantation of an Amplatzer atrial septal occluder device
    • Rabkin DG, Whitehead KJ, Michaels AD, Powell DL, Karwande SV. Unusual presentation of nickel allergy requiring explantation of an Amplatzer atrial septal occluder device. Clin Cardiol 2009, 32: e55-57.
    • (2009) Clin Cardiol , vol.32
    • Rabkin, D.G.1    Whitehead, K.J.2    Michaels, A.D.3    Powell, D.L.4    Karwande, S.V.5
  • 15
    • 77951960387 scopus 로고    scopus 로고
    • Gold-coated pacemaker implantation after allergic reactions to pacemaker compounds
    • Syburra T, Schurr U, Rahn M, Graves K, Genoni M. Gold-coated pacemaker implantation after allergic reactions to pacemaker compounds. Europace 2010, 12: 749-50.
    • (2010) Europace , vol.12 , pp. 749-750
    • Syburra, T.1    Schurr, U.2    Rahn, M.3    Graves, K.4    Genoni, M.5
  • 16
    • 33748454877 scopus 로고    scopus 로고
    • Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema, and T-cell hyperresponsiveness in vitro: Case report and review of the literature
    • DOI 10.1111/j.1600-0536.2006.00931.x
    • Thomas P, Bandl WD, Maier S, Summer B, Przybilla B. Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema, and T-cell hyperresponsiveness in vitro: case report and review of the literature. Contact dermatitis 2006, 55: 199-202. (Pubitemid 44350942)
    • (2006) Contact Dermatitis , vol.55 , Issue.4 , pp. 199-202
    • Thomas, P.1    Bandl, W.-D.2    Maier, S.3    Summer, B.4    Przybilla, B.5
  • 17
    • 84889726818 scopus 로고    scopus 로고
    • Diagnostics of metal intolerance - Correlation between patch testing and Melisa® test
    • Tomka M, Prochazkova J, Podzimek S. Diagnostics of metal intolerance - correlation between patch testing and Melisa® test. Dermatologie in beru und umwelt 2007, 55: 103.
    • (2007) Dermatologie in Beru und Umwelt , vol.55 , pp. 103
    • Tomka, M.1    Prochazkova, J.2    Podzimek, S.3
  • 18
    • 34047211957 scopus 로고    scopus 로고
    • LTT-Melisa is clinically relevant for detecting and monitoring metal sensitivity
    • Valentine-Thon E, Mu{combining double acute accent}ller K, Guzzi G, Kreisel S, Ohnsorge P, Sandkamp M. LTT-Melisa is clinically relevant for detecting and monitoring metal sensitivity. Neuro Endocrin Lett 2006, 27 (Suppl 1): 17-24.
    • (2006) Neuro Endocrin Lett , vol.27 , Issue.SUPPL. 1 , pp. 17-24
    • Valentine-Thon, E.1    Muller, K.2    Guzzi, G.3    Kreisel, S.4    Ohnsorge, P.5    Sandkamp, M.6
  • 19
    • 84889744285 scopus 로고    scopus 로고
    • www.amplatzer.com
  • 20
    • 84889722665 scopus 로고    scopus 로고
    • www.epitesty.cz


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.