메뉴 건너뛰기




Volumn 43, Issue 6, 2012, Pages 749-756

Computer navigation in the reduction and fixation of femoral shaft fractures: A randomized control study

Author keywords

Computer navigation; Femur shaft fracture; Fixation; Randomized control study; Reduction

Indexed keywords

ADULT; AGED; ARTICLE; BONE NAIL; CADAVER; CLINICAL ARTICLE; COMPUTER; FEMALE; FEMUR SHAFT FRACTURE; FLUOROSCOPY; FRACTURE FIXATION; FRACTURE REDUCTION; HUMAN; LEG LENGTH; MALE; PRIORITY JOURNAL; ROTATION;

EID: 84860741708     PISSN: 00201383     EISSN: 18790267     Source Type: Journal    
DOI: 10.1016/j.injury.2011.08.020     Document Type: Article
Times cited : (18)

References (19)
  • 1
    • 0023722766 scopus 로고
    • Epidemiology of diaphyseal and distal femoral fractures in Rochester, Minnesota, 1965-1984
    • T.J. Arneson, L.J. Melton 3rd, D.G. Lewallen, and W.M. O'Fallon Epidemiology of diaphyseal and distal femoral fractures in Rochester, Minnesota, 1965-1984 Clin Orthop Relat Res 234 1988 188 194
    • (1988) Clin Orthop Relat Res , vol.234 , pp. 188-194
    • Arneson, T.J.1    Melton III, L.J.2    Lewallen, D.G.3    O'Fallon, W.M.4
  • 4
    • 0021885423 scopus 로고
    • Closed locked intramedullary nailing. Its application to comminuted fractures of the femur
    • I. Kempf, A. Grosse, and G. Beck Closed locked intramedullary nailing. Its application to comminuted fractures of the femur J Bone Joint Surg Am 67 1985 709 720 (Pubitemid 15063849)
    • (1985) Journal of Bone and Joint Surgery - Series A , vol.67 , Issue.5 , pp. 709-720
    • Kempf, I.1    Grosse, A.2    Beck, G.3
  • 6
    • 0031757309 scopus 로고    scopus 로고
    • Intraoperative control of axes, rotation and length in femoral and tibial fractures. Technical note
    • C. Krettek, T. Miclau, O. Gruin, P. Schandelmaier, and H. Tscherne Intraoperative control of axes, rotation and length in femoral and tibial fractures. Technical note Injury 29 Suppl 3 1998 C29 C39
    • (1998) Injury , vol.29 , Issue.SUPPL 3
    • Krettek, C.1    Miclau, T.2    Gruin, O.3    Schandelmaier, P.4    Tscherne, H.5
  • 7
    • 0028925580 scopus 로고
    • Femoral torsion after interlocked nailing of unstable femoral fractures
    • P. Tornetta 3rd, G. Ritz, and A. Kantor Femoral torsion after interlocked nailing of unstable femoral fractures J Trauma 38 1995 213 219
    • (1995) J Trauma , vol.38 , pp. 213-219
    • Tornetta III, P.1    Ritz, G.2    Kantor, A.3
  • 8
    • 33745324485 scopus 로고    scopus 로고
    • Effect of one- and two-pin reference anchoring systems on marker stability during total knee arthroplasty computer navigation
    • DOI 10.1080/10929080600668122, PII J177238676251660
    • W.M. Mihalko, T. Duquin, J.R. Axelrod, M. Bayers-Thering, and K.A. Krackow Effect of one- and two-pin reference anchoring systems on marker stability during total knee arthroplasty computer navigation Comput Aided Surg 11 2006 93 98 (Pubitemid 43932728)
    • (2006) Computer Aided Surgery , vol.11 , Issue.2 , pp. 93-98
    • Mihalko, W.1    Duquin, T.2    Axelrod, J.3    Bayers-Thering, M.4    Krackow, K.5
  • 10
    • 34248588093 scopus 로고    scopus 로고
    • Fracture-table-mounted versus bone-mounted dynamic reference frame tracking accuracy using computer-assisted orthopaedic surgery - A comparative study
    • DOI 10.1080/10929080701300310, PII 778345492
    • I. Ilsar, Y.A. Weil, L. Joskowicz, R. Mosheiff, and M. Liebergall Fracture-table-mounted versus bone-mounted dynamic reference frame tracking accuracy using computer-assisted orthopaedic surgery - a comparative study Comput Aided Surg 12 2007 125 130 (Pubitemid 46752423)
    • (2007) Computer Aided Surgery , vol.12 , Issue.2 , pp. 125-130
    • Ilsar, I.1    Weil, Y.A.2    Joskowicz, L.3    Mosheiff, R.4    Liebergall, M.5
  • 12
    • 0032052299 scopus 로고    scopus 로고
    • A technique to obtain correct rotational alignment during closed locked intramedullary nailing of the femur
    • DOI 10.1016/S0020-1383(97)00182-4, PII S0020138397001824
    • R.G. Deshmukh, K.K. Lou, C.B. Neo, K.S. Yew, I. Rozman, and J. George A technique to obtain correct rotational alignment during closed locked intramedullary nailing of the femur Injury 29 1998 207 210 (Pubitemid 28271919)
    • (1998) Injury , vol.29 , Issue.3 , pp. 207-210
    • Deshmukh, R.G.1    Lou, K.K.2    Neo, C.B.3    Yew, K.S.4    Rozman, I.5    George, J.6
  • 14
    • 0027220194 scopus 로고
    • Torsional deformity after intramedullary nailing of femoral shaft fractures. Measurement of anteversion angles in 110 patients
    • M. Braten, T. Terjesen, and I. Rossvoll Torsional deformity after intramedullary nailing of femoral shaft fractures. Measurement of anteversion angles in 110 patients J Bone Joint Surg Br 75 1993 799 803 (Pubitemid 23267951)
    • (1993) Journal of Bone and Joint Surgery - Series B , vol.75 , Issue.5 , pp. 799-803
    • Braten, M.1    Terjesen, T.2    Rossvoll, I.3
  • 15
    • 33747588073 scopus 로고    scopus 로고
    • Limb malalignment and functional outcome after antegrade versus retrograde intramedullary nailing in distal femoral fractures
    • DOI 10.1097/01.ta.0000230282.65606.81, PII 0000537320060800000019
    • K.H. Salem, D. Maier, P. Keppler, L. Kinzl, and F. Gebhard Limb malalignment and functional outcome after antegrade versus retrograde intramedullary nailing in distal femoral fractures J Trauma 61 2006 375 381 (Pubitemid 44265819)
    • (2006) Journal of Trauma - Injury, Infection and Critical Care , vol.61 , Issue.2 , pp. 375-381
    • Salem, K.H.1    Maier, D.2    Keppler, P.3    Kinzl, L.4    Gebhard, F.5
  • 16
    • 34447311641 scopus 로고    scopus 로고
    • Computer navigation allows for accurate reduction of femoral fractures
    • DOI 10.1097/BLO.0b013e31804d2355, PII 0000308620070700000029
    • Y. Weil, M.J. Gardner, D.L. Helfet, and A.D. Pearle Computer navigation allows for accurate reduction of femoral fractures Clin Orthop Relat Res 460 2007 185 191 (Pubitemid 47056496)
    • (2007) Clinical Orthopaedics and Related Research , Issue.460 , pp. 185-191
    • Weil, Y.A.1    Gardner, M.J.2    Helfet, D.L.3    Pearle, A.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.