메뉴 건너뛰기




Volumn 175, Issue 2, 2012, Pages 191-198

Real-time monitoring for detection of retained surgical sponges and team motion in the surgical operation room using radio-frequency-identification (RFID) technology: A preclinical evaluation

Author keywords

active RFID; gossypiboma; passive RFID; radio frequency identification (RFID); real time OR team tracking; real time sponge tracking; retained sponge; situational awareness

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; FEASIBILITY STUDY; FOREIGN BODY; IN VITRO STUDY; IN VIVO STUDY; NONHUMAN; OPERATING ROOM; OPERATING ROOM PERSONNEL; PATIENT POSITIONING; PERITONEAL CAVITY; PILOT STUDY; PRIORITY JOURNAL; RADIOFREQUENCY IDENTIFICATION; RELIABILITY; SURGICAL EQUIPMENT; SURGICAL SPONGE; TEMPERATURE MEASUREMENT; TEXTILE;

EID: 84860737237     PISSN: 00224804     EISSN: 10958673     Source Type: Journal    
DOI: 10.1016/j.jss.2011.03.029     Document Type: Article
Times cited : (36)

References (25)
  • 2
    • 79954422347 scopus 로고    scopus 로고
    • New technologies for information retrieval to achieve situational awareness and higher patient safety in the surgical operating room: The MRI institutional approach and review of the literature
    • M. Kranzfelder, A. Schneider, and S. Gillen New technologies for information retrieval to achieve situational awareness and higher patient safety in the surgical operating room: the MRI institutional approach and review of the literature Surg Endosc 25 2011 696
    • (2011) Surg Endosc , vol.25 , pp. 696
    • Kranzfelder, M.1    Schneider, A.2    Gillen, S.3
  • 3
    • 79951613823 scopus 로고    scopus 로고
    • Discovery of high-level tasks in the operating room
    • [Epub ahead of print]
    • L. Bouarfa, P.P. Jonker, and J. Dankelman Discovery of high-level tasks in the operating room J Biomed Inform 2010 Jan 7 [Epub ahead of print]
    • (2010) J Biomed Inform
    • Bouarfa, L.1    Jonker, P.P.2    Dankelman, J.3
  • 4
    • 57349102338 scopus 로고    scopus 로고
    • Validation of knowledge acquisition for surgical process models
    • T. Neumuth, P. Jannin, and G. Strauss Validation of knowledge acquisition for surgical process models J Am Med Inform Assoc 16 2009 72
    • (2009) J Am Med Inform Assoc , vol.16 , pp. 72
    • Neumuth, T.1    Jannin, P.2    Strauss, G.3
  • 5
    • 59349089521 scopus 로고    scopus 로고
    • RFID in the healthcare supply chain: Usage and application
    • S. Kumar, E. Swanson, and T. Tran RFID in the healthcare supply chain: Usage and application Int J Health Care Qual Assur 22 2009 67
    • (2009) Int J Health Care Qual Assur , vol.22 , pp. 67
    • Kumar, S.1    Swanson, E.2    Tran, T.3
  • 6
    • 33744793183 scopus 로고    scopus 로고
    • Radio-frequency identification systems technology in the surgical setting
    • P. Nagy, I. George, and W. Bernstein Radio-frequency identification systems technology in the surgical setting Surg Innov 13 2006 61
    • (2006) Surg Innov , vol.13 , pp. 61
    • Nagy, P.1    George, I.2    Bernstein, W.3
  • 7
    • 34347374676 scopus 로고    scopus 로고
    • Radio frequency identification (RFID) applied to surgical sponges
    • A. Rogers, E. Jones, and D. Oleynikov Radio frequency identification (RFID) applied to surgical sponges Surg Endosc 21 2007 1235
    • (2007) Surg Endosc , vol.21 , pp. 1235
    • Rogers, A.1    Jones, E.2    Oleynikov, D.3
  • 8
    • 33747457789 scopus 로고    scopus 로고
    • The emergence of radiofrequency identification tags: Applications in surgery
    • S.D. Schwaitzberg The emergence of radiofrequency identification tags: Applications in surgery Surg Endosc 20 2006 1315
    • (2006) Surg Endosc , vol.20 , pp. 1315
    • Schwaitzberg, S.D.1
  • 9
    • 77951018240 scopus 로고    scopus 로고
    • Custom active RFID solution for children tracking and identifying in a resuscitation ward
    • E. Iadanza, and F. Dori Custom active RFID solution for children tracking and identifying in a resuscitation ward Conf Proc IEEE Eng Med Biol Soc 2009 2009 5223
    • (2009) Conf Proc IEEE Eng Med Biol Soc , vol.2009 , pp. 5223
    • Iadanza, E.1    Dori, F.2
  • 10
    • 0037448346 scopus 로고    scopus 로고
    • Risk factors for retained instruments and sponges after surgery
    • A.A. Gawande, D.M. Studdert, and E.J. Orav Risk factors for retained instruments and sponges after surgery N Engl J Med 348 2003 229
    • (2003) N Engl J Med , vol.348 , pp. 229
    • Gawande, A.A.1    Studdert, D.M.2    Orav, E.J.3
  • 11
    • 68049089962 scopus 로고    scopus 로고
    • Improving safety in the operating room: A systematic literature review of retained surgical sponges
    • W. Wan, T. Le, and L. Riskin Improving safety in the operating room: A systematic literature review of retained surgical sponges Curr Opin Anaesthesiol 22 2009 207
    • (2009) Curr Opin Anaesthesiol , vol.22 , pp. 207
    • Wan, W.1    Le, T.2    Riskin, L.3
  • 12
    • 33746034614 scopus 로고    scopus 로고
    • Initial clinical evaluation of a handheld device for detecting retained surgical gauze sponges using radiofrequency identification technology
    • A. Macario, D. Morris, and S. Morris Initial clinical evaluation of a handheld device for detecting retained surgical gauze sponges using radiofrequency identification technology Arch Surg 141 2006 659
    • (2006) Arch Surg , vol.141 , pp. 659
    • MacArio, A.1    Morris, D.2    Morris, S.3
  • 13
    • 61849162641 scopus 로고    scopus 로고
    • Patients tracking and identifying inside hospital: A multilayer method to plan an RFId solution
    • E. Iadanza, F. Dori, and R. Miniati Patients tracking and identifying inside hospital: A multilayer method to plan an RFId solution Conf Proc IEEE Eng Med Biol Soc 2008 2008 1462
    • (2008) Conf Proc IEEE Eng Med Biol Soc , vol.2008 , pp. 1462
    • Iadanza, E.1    Dori, F.2    Miniati, R.3
  • 15
    • 62949147625 scopus 로고    scopus 로고
    • Comparison of RFID systems for tracking clinical interventions at the bedside
    • K. Ohashi, S. Ota, and L. Ohno-Machado Comparison of RFID systems for tracking clinical interventions at the bedside AMIA Annu Symp Proc 2008 Nov 6 525
    • (2008) AMIA Annu Symp Proc , pp. 525
    • Ohashi, K.1    Ota, S.2    Ohno-Machado, L.3
  • 16
    • 45849144067 scopus 로고    scopus 로고
    • Electromagnetic interference from radio frequency identification inducing potentially hazardous incidents in critical care medical equipment
    • T.R. van der, E.J. van Lieshout, and R. Hensbroek Electromagnetic interference from radio frequency identification inducing potentially hazardous incidents in critical care medical equipment JAMA 299 2008 2884
    • (2008) JAMA , vol.299 , pp. 2884
    • Van Der, T.R.1    Van Lieshout, E.J.2    Hensbroek, R.3
  • 17
    • 67849117226 scopus 로고    scopus 로고
    • The "eLITE" model: Construct validation of a new training system for natural orifice transluminal endoscopic surgery (NOTES)
    • S. Gillen, D. Wilhelm, and A. Meining The "ELITE" model: Construct validation of a new training system for natural orifice transluminal endoscopic surgery (NOTES) Endoscopy 41 2009 395
    • (2009) Endoscopy , vol.41 , pp. 395
    • Gillen, S.1    Wilhelm, D.2    Meining, A.3
  • 19
    • 84933392900 scopus 로고
    • Communication by means of reflected power
    • H. Stockman Communication by means of reflected power Proc IRE 36 1948 1196
    • (1948) Proc IRE , vol.36 , pp. 1196
    • Stockman, H.1
  • 20
    • 79959759801 scopus 로고    scopus 로고
    • Two RFID-based solutions to enhance inpatient medication safety
    • [Epub ahead of print]
    • H.Y. Chien, C.C. Yang, and T.C. Wu Two RFID-based solutions to enhance inpatient medication safety J Med Syst 2009 Sep 25 [Epub ahead of print]
    • (2009) J Med Syst
    • Chien, H.Y.1    Yang, C.C.2    Wu, T.C.3
  • 22
    • 0033254713 scopus 로고    scopus 로고
    • AORN Recommended Practices Committee. Association of periOperative Registered Nurses
    • Recommended practices for sponge, sharp, and instrument counts
    • Recommended practices for sponge, sharp, and instrument counts AORN Recommended Practices Committee. Association of periOperative Registered Nurses AORN J 70 1999 1083
    • (1999) AORN J , vol.70 , pp. 1083
  • 24
    • 84860722076 scopus 로고    scopus 로고
    • Accessed on September 15, 2010
    • Datamars RFID Provider. Available at: http://www.datamars.com. Accessed on September 15, 2010.
    • Datamars RFID Provider
  • 25
    • 14644418428 scopus 로고    scopus 로고
    • Electronic tagging of surgical sponges to prevent their accidental retention
    • C.E. Fabian Electronic tagging of surgical sponges to prevent their accidental retention Surgery 137 2005 298
    • (2005) Surgery , vol.137 , pp. 298
    • Fabian, C.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.