메뉴 건너뛰기




Volumn 8314, Issue , 2012, Pages

Towards automatic quantitative quality control for MRI

Author keywords

Bias assessment; Bootstrap; Cluster computing; DTI; MRI; Quality control

Indexed keywords

AUTOMATIC IDENTIFICATION; BIAS ASSESSMENT; BIAS ESTIMATE; BOOTSTRAP; COMMON FACTORS; DTI; EXPERIMENTAL PROTOCOLS; EXPERIMENTAL TEST; IMAGING ARTIFACTS; MRI SCANNERS; PARALLEL PROCESSING; POWER CALCULATION; QUALITY ANALYSIS; QUALITY ASSESSMENT; RESEARCH DATA; SOFTWARE UPDATES; SPECIFIC POWER; STANDARD PRACTICES; VISUAL ASSESSMENTS; WILD BOOTSTRAP;

EID: 84860719644     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.910819     Document Type: Conference Paper
Times cited : (5)

References (10)
  • 2
    • 0036869232 scopus 로고    scopus 로고
    • Diffusion-tensor MRI: Theory, experimental design and data analysis - A technical review
    • DOI 10.1002/nbm.783
    • P. J. Basser, and D. K. Jones, "Diffusion-tensor MRI: theory, experimental design and data analysis - a technical review," NMR Biomed, 15(7-8), 456-67 (2002). (Pubitemid 36054509)
    • (2002) NMR in Biomedicine , vol.15 , Issue.7-8 , pp. 456-467
    • Basser, P.J.1    Jones, D.K.2
  • 3
    • 35248816901 scopus 로고    scopus 로고
    • Effects of signal-to-noise ratio on the accuracy and reproducibility of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5T
    • DOI 10.1002/jmri.21053
    • J. A. Farrell, B. A. Landman, C. K. Jones et al., "Effects of signal-to-noise ratio on the accuracy and reproducibility of diffusion tensor imaging-derived fractional anisotropy, mean diffusivity, and principal eigenvector measurements at 1.5 T," J Magn Reson Imaging, 26(3), 756-67 (2007). (Pubitemid 350194602)
    • (2007) Journal of Magnetic Resonance Imaging , vol.26 , Issue.3 , pp. 756-767
    • Farrell, J.A.D.1    Landman, B.A.2    Jones, C.K.3    Smith, S.A.4    Prince, J.L.5    Van Zijl, P.C.M.6    Mori, S.7
  • 4
    • 40649103454 scopus 로고    scopus 로고
    • Using the wild bootstrap to quantify uncertainty in diffusion tensor imaging
    • DOI 10.1002/hbm.20395
    • B. Whitcher, D. S. Tuch, J. J. Wisco et al., "Using the wild bootstrap to quantify uncertainty in diffusion tensor imaging," Hum Brain Mapp, 29(3), 346-62 (2008). (Pubitemid 351374393)
    • (2008) Human Brain Mapping , vol.29 , Issue.3 , pp. 346-362
    • Whitcher, B.1    Tuch, D.S.2    Wisco, J.J.3    Sorensen, A.G.4    Wang, L.5
  • 8
    • 0028839871 scopus 로고
    • The rician distribution of noisy MRI data
    • H. Gudbjartsson, and S. Patz, "The Rician distribution of noisy MRI data," Magn Reson Med, 34(6), 910-4 (1995).
    • (1995) Magn Reson Med , vol.34 , Issue.6 , pp. 910-914
    • Gudbjartsson, H.1    Patz, S.2
  • 9
    • 7544247899 scopus 로고    scopus 로고
    • "Squashing peanuts and smashing pumpkins": How noise distorts diffusion-weighted MR data
    • DOI 10.1002/mrm.20283
    • D. K. Jones, and P. J. Basser, ""Squashing peanuts and smashing pumpkins": How noise distorts diffusion-weighted MR data," Magnetic Resonance in Medicine, 52(5), 979-993 (2004). (Pubitemid 39453270)
    • (2004) Magnetic Resonance in Medicine , vol.52 , Issue.5 , pp. 979-993
    • Jones, D.K.1    Basser, P.J.2
  • 10
    • 78650936662 scopus 로고    scopus 로고
    • Multi-parametric neuroimaging reproducibility: A 3T resource study
    • B. A. Landman, A. J. Huang, A. Gifford et al., "Multi-Parametric Neuroimaging Reproducibility: A 3T Resource Study," Neuroimage, 54(4), 12 (2010).
    • (2010) Neuroimage , vol.54 , Issue.4 , pp. 12
    • Landman, B.A.1    Huang, A.J.2    Gifford, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.