Volumn 1, Issue , 2011, Pages 699-703

Study on the impacts of wind farms on outgoing line relay protection based on the development of digital-physical hybrid simulation system for VSCF wind turbine

Author keywords

digital physical hybrid simulation system; relay protection; RTDS; VSCF; wind farms

Indexed keywords

CAPABILITY DESCRIPTION; HYBRID SIMULATION; IEC 61850; INFORMATION FILES; INFORMATION TRANSFERS; RTDS; SUBSTATION CONFIGURATIONS; SYSTEM SPECIFICATION; VSCF; WIND FARM;

EID: 84860687696     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/APAP.2011.6180488     Document Type: Conference Paper
Times cited : (1)

References (13)
  • 1
    • 16644367195 scopus 로고    scopus 로고
    • Studies on wind farm integration into power system
    • Lei Y ZH. Studies on wind farm integration into power system. Power system automation, 2003, 27(8): 84-89
    • (2003) Power System Automation , vol.27 , Issue.8 , pp. 84-89
    • Lei, Y.Z.H.1
  • 2
    • 79955066803 scopus 로고    scopus 로고
    • Impacts of wind farm central integration on local power grids
    • Xu X Y, Shi W H, Li Y CH, et al. Impacts of wind farm central integration on local power grids. Electric Power, 2009, 42(1): 93-97
    • (2009) Electric Power , vol.42 , Issue.1 , pp. 93-97
    • Xu, X.Y.1    Shi, W.H.2    Li, Y.C.H.3
  • 3
    • 51649102053 scopus 로고    scopus 로고
    • A control strategy on the variable-speed constant-frequency wind turbine
    • Shu J, Zhang B H, Li P, et al. A control strategy on the variable-speed constant-frequency wind turbine. Power system automation, 2008, 32(16): 89-93, 97
    • (2008) Power System Automation , vol.32 , Issue.16
    • Shu, J.1    Zhang, B.H.2    Li, P.3
  • 4
    • 79955516173 scopus 로고    scopus 로고
    • Impacts of wind farm on relay protection for distribution network and its countermeasures
    • Yang G SH, Li X, Zhou Z X. Impacts of wind farm on relay protection for distribution network and its countermeasures. Power system technology, 2009, 33(11): 87-91, 103
    • (2009) Power System Technology , vol.33 , Issue.11
    • Yang, G.S.H.1    Li, X.2    Zhou, Z.X.3
  • 5
    • 0026238031 scopus 로고    scopus 로고
    • Active and reactive power control for doubly-fed wound rotor induction generator
    • Mitsutoshi Yamamoto, Osamu Motoyoshi. Active and reactive power control for doubly-fed wound rotor induction generator. IEEE Trans. On Power Electronics, 1997, 6(4): 624-629
    • (1997) IEEE Trans. on Power Electronics , vol.6 , Issue.4 , pp. 624-629
    • Yamamoto, M.1    Motoyoshi, O.2
  • 6
    • 0442279370 scopus 로고    scopus 로고
    • The maximal wind-energy tracing control of a variable-speed constant-frequency wind-power generation system
    • Liu Q H, He Y K and Zhao R D. The maximal wind-energy tracing control of a variable-speed constant-frequency wind-power generation system. Power system automation, 2003, 27: 62-67
    • (2003) Power System Automation , vol.27 , pp. 62-67
    • Liu, Q.H.1    He, Y.K.2    Zhao, R.D.3
  • 7
    • 77955822790 scopus 로고    scopus 로고
    • Penetration level permission of for DG in distributed network considering relay protection
    • Wang J H, Tai N L, Song K, et al. Penetration level permission of for DG in distributed network considering relay protection. Proceedings of the CSEE, 2010, 30(22): 37-43
    • (2010) Proceedings of the CSEE , vol.30 , Issue.22 , pp. 37-43
    • Wang, J.H.1    Tai, N.L.2    Song, K.3
  • 8
    • 77957605946 scopus 로고    scopus 로고
    • Problems and measures of power grid accommodating large scale wind power
    • Zhang L Y, Ye T L, Xin Y ZH, et al. Problems and measures of power grid accommodating large scale wind power. Proceedings of the CSEE, 2010, 30(25): 1-9
    • (2010) Proceedings of the CSEE , vol.30 , Issue.25 , pp. 1-9
    • Zhang, L.Y.1    Ye, T.L.2    Xin, Y.Z.H.3
  • 9
    • 33749029254 scopus 로고    scopus 로고
    • Impact of large scale wind farm integration on power system transient stability
    • Chi Y N, Wang W S, Liu Y H, et al. Impact of large scale wind farm integration on power system transient stability. Power system automation, 2006, 30(15): 10-15
    • (2006) Power System Automation , vol.30 , Issue.15 , pp. 10-15
    • Chi, Y.N.1    Wang, W.S.2    Liu, Y.H.3
  • 11
    • 0035304577 scopus 로고    scopus 로고
    • Investigating the impact of embedded generation on relay settings of utilities' electrical feeders
    • Salman K, Ibrahim M Rida. Investigating the impact of embedded generation on relay settings of utilities' electrical feeders. IEEE Transactions on Power Delivery, 2001, 16(2): 246-251
    • (2001) IEEE Transactions on Power Delivery , vol.16 , Issue.2 , pp. 246-251
    • Salman, K.1    Rida, I.M.2
  • 12
    • 33846998365 scopus 로고    scopus 로고
    • Characteristics of induction generators and power system stability
    • CHEN Z. Characteristics of induction generators and power system stability. Electrical Machines and Systems, 2005, 2: 919-924
    • (2005) Electrical Machines and Systems , vol.2 , pp. 919-924
    • Chen, Z.1
  • 13
    • 33947655421 scopus 로고    scopus 로고
    • Impacts of wind power on thermal generation unit commitment and dispatch
    • DOI 10.1109/TEC.2006.889616, Special Issue on Wind Power
    • Brand A J, Gibescu M, Kling W L, et al. Impacts of wind power on thermal generation unit commitment and dispatch. IEEE Transactions on Energy Conversion, 2007, 22(1): 44-51 (Pubitemid 46487475)
    • (2007) IEEE Transactions on Energy Conversion , vol.22 , Issue.1 , pp. 44-51
    • Ummels, B.C.1    Gibescu, M.2    Pelgrum, E.3    Kling, W.L.4    Brand, A.J.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.