메뉴 건너뛰기




Volumn 57, Issue , 2012, Pages 18-27

Acoustic approach for building air permeability estimation

Author keywords

Airborne noise; Experimental measurements; Facade transfer; Permeability law

Indexed keywords

ACCURATE ESTIMATION; ACOUSTIC METHOD; AIR CHANGE RATES; AIR FLOW; AIR INFILTRATION; AIR PERMEABILITY MEASUREMENT; AIR-BORNE NOISE; AIRTIGHTNESS; EXPERIMENTAL APPROACHES; EXPERIMENTAL MEASUREMENTS; FAST TOOL; HVAC DESIGNS; MEASUREMENT DEVICE; NOISE TRANSFER; PERMEABILITY ESTIMATION; PREDICTION MODEL; SOUND TRANSMISSION LOSS; TRANSFER PHENOMENON;

EID: 84860647389     PISSN: 03601323     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.buildenv.2012.04.008     Document Type: Article
Times cited : (35)

References (43)
  • 1
    • 80054096027 scopus 로고    scopus 로고
    • IEQ assessment on schools in the design stage
    • Catalina T., Iordache V. IEQ assessment on schools in the design stage. Building Environ 2012, 49:129-140.
    • (2012) Building Environ , vol.49 , pp. 129-140
    • Catalina, T.1    Iordache, V.2
  • 2
    • 78649443276 scopus 로고    scopus 로고
    • Lobed grilles for high mixing ventilation - an experimental analysis in a full scale model room
    • Nastase I., Meslem A., Iordache V., Colda I. Lobed grilles for high mixing ventilation - an experimental analysis in a full scale model room. Building Environ March 2011, 46(3):547-555.
    • (2011) Building Environ , vol.46 , Issue.3 , pp. 547-555
    • Nastase, I.1    Meslem, A.2    Iordache, V.3    Colda, I.4
  • 4
    • 0032309644 scopus 로고    scopus 로고
    • Air tightness of US dwellings
    • Sherman M., Dickerhoff D. Air tightness of US dwellings. ASHRAE Trans 1998, 104(2):1359-1367.
    • (1998) ASHRAE Trans , vol.104 , Issue.2 , pp. 1359-1367
    • Sherman, M.1    Dickerhoff, D.2
  • 7
    • 20444441159 scopus 로고    scopus 로고
    • Analyzing a database of residential air leakage in the United States
    • Chan W.R., Nazaroff W.W., Price P.N., Sohn M.D., Gadgil A.J. Analyzing a database of residential air leakage in the United States. Atmos Environ 2005, 39(19):3445-3455.
    • (2005) Atmos Environ , vol.39 , Issue.19 , pp. 3445-3455
    • Chan, W.R.1    Nazaroff, W.W.2    Price, P.N.3    Sohn, M.D.4    Gadgil, A.J.5
  • 9
    • 55749091667 scopus 로고    scopus 로고
    • Building leakage, infiltration, and energy performance analyses for Finnish detached houses
    • Jokisalo J., Kurnitski J., Korpi M., Kalamees T., Vinha J. Building leakage, infiltration, and energy performance analyses for Finnish detached houses. Building Environ 2009, 44(2):377-387.
    • (2009) Building Environ , vol.44 , Issue.2 , pp. 377-387
    • Jokisalo, J.1    Kurnitski, J.2    Korpi, M.3    Kalamees, T.4    Vinha, J.5
  • 10
    • 76349116270 scopus 로고    scopus 로고
    • Air leakage in Catalan dwellings: developing an airtightness model and leakage airflow predictions
    • Montoya M., Pastor E., Carrié F., Guyot G., Planas E. Air leakage in Catalan dwellings: developing an airtightness model and leakage airflow predictions. Building Environ 2010, 45(6):1458-1469.
    • (2010) Building Environ , vol.45 , Issue.6 , pp. 1458-1469
    • Montoya, M.1    Pastor, E.2    Carrié, F.3    Guyot, G.4    Planas, E.5
  • 11
    • 0036467397 scopus 로고    scopus 로고
    • Multicriteria analysis of ventilation in summer period
    • Blondeau P., Spérandio M., Allard F. Multicriteria analysis of ventilation in summer period. Building Environ 2002, 37(2):165-176.
    • (2002) Building Environ , vol.37 , Issue.2 , pp. 165-176
    • Blondeau, P.1    Spérandio, M.2    Allard, F.3
  • 12
    • 84864034590 scopus 로고    scopus 로고
    • Envelope and ductwork air tightness data in France: field practice
    • In: Proceedings of the First Blower Door European Symposium. Fulda; 23, 24 June
    • Litvak A, Fournier M, Carrie F. Envelope and ductwork air tightness data in France: field practice, regulatory approach, energy implications and progress needed. In: Proceedings of the First Blower Door European Symposium. Fulda; 23, 24 June 2006.
    • (2006) regulatory approach, energy implications and progress needed
    • Litvak, A.1    Fournier, M.2    Carrie, F.3
  • 13
    • 84864035743 scopus 로고    scopus 로고
    • Building air tightness and dwelling ventilation -experiences in Italy
    • in Gantioler G. Building air tightness and dwelling ventilation -experiences in Italy. In: Proceedings of the First Blower Door European Symposium. Fulda; 23, 24 June
    • Gantioler G. Building air tightness and dwelling ventilation -experiences in Italy, in Gantioler G. Building air tightness and dwelling ventilation -experiences in Italy. In: Proceedings of the First Blower Door European Symposium. Fulda; 23, 24 June 2006.
    • (2006)
    • Gantioler, G.1
  • 14
    • 0022867720 scopus 로고
    • Air permeability in some Australian houses
    • Biggs L., Benni I., Michell D. Air permeability in some Australian houses. Building Environ 1986, 21(2):89-96.
    • (1986) Building Environ , vol.21 , Issue.2 , pp. 89-96
    • Biggs, L.1    Benni, I.2    Michell, D.3
  • 15
    • 0003417018 scopus 로고
    • Changes in air leakage levels of six Canadian office buildings
    • Shaw C., Reardon J., Cheung M. Changes in air leakage levels of six Canadian office buildings. ASHRAE J 1993.
    • (1993) ASHRAE J
    • Shaw, C.1    Reardon, J.2    Cheung, M.3
  • 16
    • 0010572210 scopus 로고
    • Infiltration-pressurization correlation: simplified physical modeling.,"
    • Sherman M., Grimsrud D. Infiltration-pressurization correlation: simplified physical modeling.,". ASHRAE Trans 1980, 86(2):778-807.
    • (1980) ASHRAE Trans , vol.86 , Issue.2 , pp. 778-807
    • Sherman, M.1    Grimsrud, D.2
  • 18
    • 6744241555 scopus 로고
    • The alberta air infiltration model. Report 71: University of Alberta
    • Walker I, Wilson D. The alberta air infiltration model. Report 71: University of Alberta, Department of Mechanical Engineering. p. 44; 1990.
    • (1990) Department of Mechanical Engineering , pp. 44
    • Walker, I.1    Wilson, D.2
  • 19
    • 0032647807 scopus 로고    scopus 로고
    • COMIS-an international multizone air-flow and contaminant transport model
    • Feustel H. COMIS-an international multizone air-flow and contaminant transport model. Energy and Buildings 1999, 30(1):3-18.
    • (1999) Energy and Buildings , vol.30 , Issue.1 , pp. 3-18
    • Feustel, H.1
  • 22
    • 55649119360 scopus 로고    scopus 로고
    • Evaluation of the alberta air infiltration model using measurements and inter-model comparisons
    • Wang W., Beausoleil-Morrison I., Reardon J. Evaluation of the alberta air infiltration model using measurements and inter-model comparisons. Building Environ 2009, 44(2):309-318.
    • (2009) Building Environ , vol.44 , Issue.2 , pp. 309-318
    • Wang, W.1    Beausoleil-Morrison, I.2    Reardon, J.3
  • 23
    • 0344894528 scopus 로고    scopus 로고
    • The influence of the user on the results of multizone air flow simulations with COMIS
    • Roulet C.-A., Fürbringer J.-M., Cretton P. The influence of the user on the results of multizone air flow simulations with COMIS. Energy and Buildings 1999, 30(1):73-86.
    • (1999) Energy and Buildings , vol.30 , Issue.1 , pp. 73-86
    • Roulet, C.-A.1    Fürbringer, J.-M.2    Cretton, P.3
  • 24
    • 78651436209 scopus 로고    scopus 로고
    • Consumuri de caldura in apartamente de bloc cu ferestre de tip termopan
    • Iordache F., Iordache V. Consumuri de caldura in apartamente de bloc cu ferestre de tip termopan. Instalatorul 2004, 8:21-25.
    • (2004) Instalatorul , vol.8 , pp. 21-25
    • Iordache, F.1    Iordache, V.2
  • 27
    • 78651432543 scopus 로고    scopus 로고
    • Average permeability measurements for an individual dwelling in Romania
    • Iordache V., Nastase I., Damian A., Colda I. Average permeability measurements for an individual dwelling in Romania. Building Environ 2011, 46(5):1115-1124.
    • (2011) Building Environ , vol.46 , Issue.5 , pp. 1115-1124
    • Iordache, V.1    Nastase, I.2    Damian, A.3    Colda, I.4
  • 28
    • 0022523956 scopus 로고
    • A sonic method for building air-leakage measurements
    • Sonoda T., Peterson F. A sonic method for building air-leakage measurements. Appl Energy 1986, 22(3):205-224. 1986, Pages 205-224, vol. 22, no. 3.
    • (1986) Appl Energy , vol.22 , Issue.3 , pp. 205-224
    • Sonoda, T.1    Peterson, F.2
  • 30
    • 84864074979 scopus 로고
    • Evaluation of an acoustical method for detecting air leaks
    • Ringger M., Hartman P. Evaluation of an acoustical method for detecting air leaks. Air Infiltration Rev December 1989, 11(1).
    • (1989) Air Infiltration Rev , vol.11 , Issue.1
    • Ringger, M.1    Hartman, P.2
  • 34
    • 0016942149 scopus 로고
    • Noise sources in swirl burners
    • Gupta A.K., Syred N., Be J.M. Noise sources in swirl burners. Appl Acoust 1976, 9(2):151-163.
    • (1976) Appl Acoust , vol.9 , Issue.2 , pp. 151-163
    • Gupta, A.K.1    Syred, N.2    Be, J.M.3
  • 35
    • 81255186395 scopus 로고    scopus 로고
    • Edition Le Moniteur, Paris
    • C M.X. L'acoustique de l'habitat 2001, Edition Le Moniteur, Paris, pp. 53-61.
    • (2001) L'acoustique de l'habitat , pp. 53-61
    • C, M.X.1
  • 37
    • 78651462086 scopus 로고    scopus 로고
    • Etude de l'impact de la pollution atmosphérique sur l'exposition des enfants en milieu scolaire, La Rochelle.
    • France: Thèse de doctorat, Université de La Rochelle
    • Iordache V. Etude de l'impact de la pollution atmosphérique sur l'exposition des enfants en milieu scolaire, La Rochelle. France: Thèse de doctorat, Université de La Rochelle; 2003.
    • (2003)
    • Iordache, V.1
  • 38
    • 84864034589 scopus 로고    scopus 로고
    • ASTM E1827-11. Standard test methods for determining airtightness of buildings using an orifice blower door.
    • ASTM E1827-11. Standard test methods for determining airtightness of buildings using an orifice blower door.
  • 40
    • 0025921799 scopus 로고
    • Use of an indoor air quality model (IAQM) to estimate indoor ozone levels
    • Hayes S. Use of an indoor air quality model (IAQM) to estimate indoor ozone levels. J Air Waste Manage Assoc 1991, 41:161-170.
    • (1991) J Air Waste Manage Assoc , vol.41 , pp. 161-170
    • Hayes, S.1
  • 41
    • 84864074977 scopus 로고
    • Ventilation strategies in case of polluted outdoor air situations.
    • Gent, Belgium; 12-15 September
    • Trepte L. Ventilation strategies in case of polluted outdoor air situations. In: 9th AIVC Conference. Gent, Belgium; 12-15 September, 1988.
    • (1988) In: 9th AIVC Conference.
    • Trepte, L.1
  • 42
    • 84864035739 scopus 로고    scopus 로고
    • Comparison of the sound reduction index of a window using pressure and intensity techniques.
    • Auckland N.Z.; November
    • Cervera F, Uris A, Gálvez F, Martinez-Sala R. Comparison of the sound reduction index of a window using pressure and intensity techniques. In: Proc. Inter Noise. Auckland N.Z.; November, 1998.
    • (1998) In: Proc. Inter Noise.
    • Cervera, F.1    Uris, A.2    Gálvez, F.3    Martinez-Sala, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.