Volumn 40, Issue 3, 2012, Pages 209-213

Applying radio-frequency identification (RFID) technology in transfusion medicine

Author keywords

13.56 MHz; Blood; ISBT 128; RFID; Transfusion safety

Indexed keywords

ARTICLE; BLOOD BANK; BLOOD DONOR; BLOOD TRANSFUSION; CENTRIFUGATION; COMPUTER SYSTEM; DISASTER; FOOD AND DRUG ADMINISTRATION; HUMAN; PRIORITY JOURNAL; RADIOFREQUENCY IDENTIFICATION; UNITED STATES;

EID: 84860638487     PISSN: 10451056     EISSN: 10958320     Source Type: Journal    
DOI: 10.1016/j.biologicals.2011.10.008     Document Type: Article
Times cited : (40)

References (12)
  • 2
    • 24044486563 scopus 로고    scopus 로고
    • Adding RFID layer to blood safety loop
    • Online:
    • Lusky K. Adding RFID layer to blood safety loop. CAP Today July 2005, 45-52. Online: http://www.cap.org/apps/docs/cap_today/.
    • (2005) CAP Today , pp. 45-52
    • Lusky, K.1
  • 3
    • 34447620453 scopus 로고    scopus 로고
    • Radio frequency identification for prevention of bedside errors
    • Dzik S. Radio frequency identification for prevention of bedside errors. Transfusion 2007, 47(suppl.):125S-129S.
    • (2007) Transfusion , vol.47 , Issue.SUPPL.
    • Dzik, S.1
  • 5
    • 33745766437 scopus 로고    scopus 로고
    • Barcode and radio-frequency technologies can increase safety and efficiency of blood transfusions
    • Sandler G., Langeberg A., Carty K., Dohnalek L.J. Barcode and radio-frequency technologies can increase safety and efficiency of blood transfusions. Lab Med 2006, 37:436-439.
    • (2006) Lab Med , vol.37 , pp. 436-439
    • Sandler, G.1    Langeberg, A.2    Carty, K.3    Dohnalek, L.J.4
  • 6
    • 77950541339 scopus 로고    scopus 로고
    • Radio frequency identification (RFID): an experience in transfusion medicine
    • Knels R. Radio frequency identification (RFID): an experience in transfusion medicine. ISBT Sci Ser 2006, 1:238-241.
    • (2006) ISBT Sci Ser , vol.1 , pp. 238-241
    • Knels, R.1
  • 7
    • 34247561923 scopus 로고    scopus 로고
    • Radiofrequency identification technology can standardize and document blood collections and transfusions
    • Sandler G.S., Langeberg A., DeBandi L., Gibble J., Wilson C., Feldman C.L. Radiofrequency identification technology can standardize and document blood collections and transfusions. Transfusion 2007, 47:763-770.
    • (2007) Transfusion , vol.47 , pp. 763-770
    • Sandler, G.S.1    Langeberg, A.2    DeBandi, L.3    Gibble, J.4    Wilson, C.5    Feldman, C.L.6
  • 8
    • 77950534048 scopus 로고    scopus 로고
    • Guidelines for the use of RFID technology in transfusion medicine, Version 1.0
    • Knels Ralf, Davis R., Ashford P., Bidet F., Boecker W., Briggs L., et al. Guidelines for the use of RFID technology in transfusion medicine, Version 1.0. Vox Sanguinis 2010, 98(Suppl. 2).
    • (2010) Vox Sanguinis , vol.98 , Issue.SUPPL. 2
    • Knels, R.1    Davis, R.2    Ashford, P.3    Bidet, F.4    Boecker, W.5    Briggs, L.6
  • 9
    • 67650362333 scopus 로고    scopus 로고
    • Design of a 13.56 MHz Segmented Helmholtz Coil for RF exposure testing of Biologics to Simulated RFID readers
    • Hohberger Clive, Tsirline B. Design of a 13.56 MHz Segmented Helmholtz Coil for RF exposure testing of Biologics to Simulated RFID readers. Int J Radio Frequency Identification Technol Appl 2009, 2:65-92.
    • (2009) Int J Radio Frequency Identification Technol Appl , vol.2 , pp. 65-92
    • Hohberger, C.1    Tsirline, B.2
  • 10
    • 77954334038 scopus 로고    scopus 로고
    • Absence of acute adverse in-vitro effects on AS-1 RBCs and whole blood-derived platelets following prolonged exposure to 13.56 MHz radio energy
    • Davis Rodeina, Gottschall J., Gutierrez A., Hohberger C., Veeramani D., Holcombe J. Absence of acute adverse in-vitro effects on AS-1 RBCs and whole blood-derived platelets following prolonged exposure to 13.56 MHz radio energy. Transfusion 2010, 50:1596-1603.
    • (2010) Transfusion , vol.50 , pp. 1596-1603
    • Davis, R.1    Gottschall, J.2    Gutierrez, A.3    Hohberger, C.4    Veeramani, D.5    Holcombe, J.6
  • 11
    • 84860637521 scopus 로고    scopus 로고
    • Limit Test results: Cellular and Protein impact of RF energy on aged Red cells and Thawed plasma. Unpublished results: Submission to the FDA dated July, from BloodCenter of Wisconsin.
    • Gottschall Jerome G, Gutierrez A, Davis R. Limit Test results: Cellular and Protein impact of RF energy on aged Red cells and Thawed plasma. Unpublished results: Submission to the FDA dated July, 2010 from BloodCenter of Wisconsin.
    • (2010)
    • Gottschall Jerome, G.1    Gutierrez, A.2    Davis, R.3
  • 12
    • 84860637522 scopus 로고    scopus 로고
    • Limit Test results: temperature Impact of HF (13.56 MHz) Radiation on aged Red Cells and Thawed plasma. Unpublished results: Submission to the FDA dated August, from BloodCenter of Wisconsin.
    • Gottschall Jerome G, Hohberger C, Gutierrez A, Davis R. Limit Test results: temperature Impact of HF (13.56 MHz) Radiation on aged Red Cells and Thawed plasma. Unpublished results: Submission to the FDA dated August, 2010 from BloodCenter of Wisconsin.
    • (2010)
    • Gottschall Jerome, G.1    Hohberger, C.2    Gutierrez, A.3    Davis, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.