메뉴 건너뛰기




Volumn , Issue , 2012, Pages 13-16

Antenna evaluation of a non-contact vital signs sensor for continuous heart and respiration rate monitoring

Author keywords

arctangent demodulation; Doppler radar; helical antenna; log periodic antenna; noncontact vital signs monitoring; patch antenna; quadrature receiver; wireless continuous monitoring; Yagi antenna

Indexed keywords

ANALOG ELECTRONICS; CONTINUOUS MONITORING; CONTINUOUS WAVE DOPPLER RADARS; HEARTBEAT SIGNALS; NON-CONTACT; QUADRATURE RECEIVERS; RESPIRATION RATE; RF RECEIVERS; SENSOR SYSTEMS; VITAL SIGN; YAGI ANTENNAS;

EID: 84860563542     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/BioWireless.2012.6172730     Document Type: Conference Paper
Times cited : (25)

References (13)
  • 1
    • 0015246223 scopus 로고
    • Contactless apnoea detector based on radar
    • October
    • C.G. Caro and J.A. Bloice, "Contactless apnoea detector based on radar", Lancet, vol. 2, no.7731, pp. 959-961, October, 1971.
    • (1971) Lancet , vol.2 , Issue.7731 , pp. 959-961
    • Caro, C.G.1    Bloice, J.A.2
  • 2
    • 0016950810 scopus 로고
    • Contactless respiration monitoring of infants
    • May
    • C.I. Franks et. al. "Contactless respiration monitoring of infants", Med. Biol. Eng. 14(3):306-312, May 1976.
    • (1976) Med. Biol. Eng. , vol.14 , Issue.3 , pp. 306-312
    • Franks, C.I.1
  • 3
    • 0018855482 scopus 로고
    • Respiratory patterns and risk of sudden unexpected death in infancy
    • C.I. Franks et.al "Respiratory patterns and risk of sudden unexpected death in infancy", Arch. Dis. Child; 55(8):595-604, 1980.
    • (1980) Arch. Dis. Child , vol.55 , Issue.8 , pp. 595-604
    • Franks, C.I.1
  • 5
    • 34248198847 scopus 로고    scopus 로고
    • Arctangent demodulation with dc offset compensation in quadrature doppler radar receiver systems
    • B.K. Park, et. al, "Arctangent Demodulation with DC Offset Compensation in Quadrature Doppler radar Receiver Systems", IEEE Trans. Microw. Theory Tech., 55, 5, pp.1073-1079, 2007.
    • (2007) IEEE Trans. Microw. Theory Tech. , vol.55 , Issue.5 , pp. 1073-1079
    • Park, B.K.1
  • 8
    • 1842527440 scopus 로고    scopus 로고
    • Range correlation and I/Q performance benefits in single chip silicon Doppler radars for non-contact cardiopulmonary monitoring
    • Mar.
    • A.D. Droitcour, et.al., "Range correlation and I/Q performance benefits in single chip silicon Doppler radars for non-contact cardiopulmonary monitoring", IEEE Trans. Microw. Theory Tech., vol.52, no.3, pp.838-848, Mar., 2004.
    • (2004) IEEE Trans. Microw. Theory Tech. , vol.52 , Issue.3 , pp. 838-848
    • Droitcour, A.D.1
  • 9
    • 77949392938 scopus 로고    scopus 로고
    • A 2.4GHz Non-contact biosensor system for continuous vital-signs monitoring on a single PCB
    • R. Ichapurapu, et. al. "A 2.4GHz Non-Contact Biosensor System for Continuous Vital-Signs Monitoring on a Single PCB", Proc. IEEE ASICON, pp. 925-928, 2009.
    • (2009) Proc. IEEE ASICON , pp. 925-928
    • Ichapurapu, R.1
  • 10
    • 0027192406 scopus 로고
    • Range correlation effects on phase and amplitude noise
    • Charlotte, NC
    • M.C. Budge Jr. and M.P. Burt, "Range Correlation Effects on Phase and Amplitude Noise", Proc. IEEE Southeastcon, Charlotte, NC, pp. 5-9, 1993.
    • (1993) Proc. IEEE Southeastcon , pp. 5-9
    • Budge Jr., M.C.1    Burt, M.P.2
  • 12
    • 70350606246 scopus 로고    scopus 로고
    • Low-cost differential front-end for Doppler radar vital sign monitoring
    • R. Fletcher and J. Han. "Low-cost differential front-end for Doppler radar vital sign monitoring." IEEE Int'l Microw. Symp. (MTT-S)Digest, pp. 1325-1328, 2009
    • (2009) IEEE Int'l Microw. Symp. (MTT-S)Digest , pp. 1325-1328
    • Fletcher, R.1    Han, J.2
  • 13
    • 33847755555 scopus 로고    scopus 로고
    • Experiment and spectral analysis of a low-power K a-band heartbeat detector measuring from four sides of a human body
    • DOI 10.1109/TMTT.2006.884652
    • C. Li, Y. Xiao and J. Lin, "Experiment and Spectral Analysis of a Low-Power Ka-Band Heartbeat Detector Measuring From Four Sides of a Human Body", IEEE Trans. Microw. Theory Tech., vol.54, No.12, pp. 4464-4471, Dec., 2006. (Pubitemid 46372455)
    • (2006) IEEE Transactions on Microwave Theory and Techniques , vol.54 , Issue.12 , pp. 4464-4471
    • Li, C.1    Xiao, Y.2    Lin, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.