-
1
-
-
13844321255
-
Selective head cooling with mild systemic hypothermia after neonatal encephalopathy: Multicentre randomised trial
-
DOI 10.1016/S0140-6736(05)17946-X
-
Gluckman PD,Wyatt JS, Azzopardi D, et al. Selective head cooling with mild systemic hypothermia after neonatal encephalopathy: Multicentre randomised trial. Lancet. 2005; 365: 663-70. (Pubitemid 40260887)
-
(2005)
Lancet
, vol.365
, Issue.9460
, pp. 663-670
-
-
Gluckman, P.D.1
Wyatt, J.S.2
Azzopardi, D.3
Ballard, R.4
Edwards, A.D.5
Ferriero, D.M.6
Polin, R.A.7
Robertson, C.M.8
Thoresen, M.9
Whitelaw, A.10
Gunn, A.J.11
-
2
-
-
0033000730
-
Assessment of neonatal encephalopathy by amplitude-integrated electroencephalography
-
DOI 10.1542/peds.103.6.1263
-
al Naqeeb N, Edwards AD, Cowan FM, Azzopardi D. Assessment of neonatal encephalopathy by amplitude-integrated electroencephalography. Pediatrics. 1999; 103: 1263-71. (Pubitemid 29258804)
-
(1999)
Pediatrics
, vol.103
, Issue.6
, pp. 1263-1271
-
-
Al Naqeeb, N.1
Edwards, A.D.2
Cowan, F.M.3
Azzopardi, D.4
-
3
-
-
0028832920
-
Predictive value of early continuous amplitude integrated EEG recordings on outcome after severe birth asphyxia in full term infants
-
Hellstrom-Westas L, Rosen I, Svenningsen NW. Predictive value of early continuous amplitude integrated EEG recordings on outcome after severe birth asphyxia in full term infants. Arch Dis Child Fetal Neonatal Ed. 1995; 72: F34-8.
-
(1995)
Arch Dis Child Fetal Neonatal Ed.
, vol.72
-
-
Hellstrom-Westas, L.1
Rosen, I.2
Svenningsen, N.W.3
-
4
-
-
2442706489
-
Prognostic significance of amplitude-integrated EEG during the first 72 hours after birth in severely asphyxiated neonates
-
DOI 10.1203/01.pdr.0000127019.52562.8c
-
ter Horst HJ, Sommer C, Bergman KA, Fock JM, vanWeerden TW, Bos AF. Prognostic significance of amplitude-integrated EEG during the first 72 hours after birth in severely asphyxiated neonates. Pediatr Res. 2004; 55: 1026-33. (Pubitemid 38661796)
-
(2004)
Pediatric Research
, vol.55
, Issue.6
, pp. 1026-1033
-
-
Ter Horst, H.J.1
Sommer, C.2
Bergman, K.A.3
Fock, J.M.4
Van Weerden, T.W.5
Bos, A.F.6
-
5
-
-
33750320583
-
Predictive value of amplitude-integrated electroencephalography pattern and voltage in asphyxiated term infants
-
DOI 10.1016/j.pediatrneurol.2006.06.007, PII S0887899406003845
-
Shany E, Goldstein E, Khvatskin S, et al. Predictive value of amplitude-integrated electroencephalography pattern and voltage in asphyxiated term infants. Pediatr Neurol. 2006; 35: 335-42. (Pubitemid 44636128)
-
(2006)
Pediatric Neurology
, vol.35
, Issue.5
, pp. 335-342
-
-
Shany, E.1
Goldstein, E.2
Khvatskin, S.3
Friger, M.D.4
Heiman, N.5
Goldstein, M.6
Karplus, M.7
Galil, A.8
-
6
-
-
0032984517
-
Amplitude integrated EEG 3 and 6 hours after birth in full term neonates with hypoxic-ischaemic encephalopathy
-
Toet MC, Hellstrom-Westas L, Groenendaal F, Eken P, de Vries LS. Amplitude integrated EEG 3 and 6 hours after birth in full term neonates with hypoxic-ischaemic encephalopathy. Arch Dis Child Fetal Neonatal Ed. 1999; 81: F19-23. (Pubitemid 29307424)
-
(1999)
Archives of Disease in Childhood: Fetal and Neonatal Edition
, vol.81
, Issue.1
-
-
Toet, M.C.1
Hellstrom-Westas, L.2
Groenendaal, F.3
Eken, P.4
De Vries, L.S.5
-
7
-
-
35148856609
-
Sensitivity of amplitude-integrated electroencephalography for neonatal seizure detection
-
DOI 10.1542/peds.2007-0514
-
Shellhaas RA, Soaita AI, Clancy RR. Sensitivity of amplitudeintegrated electroencephalography for neonatal seizure detection. Pediatrics. 2007; 120: 770-7. (Pubitemid 47549565)
-
(2007)
Pediatrics
, vol.120
, Issue.4
, pp. 770-777
-
-
Shellhaas, R.A.1
Soaita, A.I.2
Clancy, R.R.3
-
8
-
-
57149089443
-
Utility of prolonged bedside amplitude-integrated encephalogram in encephalopathic infants
-
Mathur AM, Morris LD, Teteh F, Inder TE, Zempel J. Utility of prolonged bedside amplitude-integrated encephalogram in encephalopathic infants. Am J Perinatol. 2008; 25: 611-15.
-
(2008)
Am J Perinatol.
, vol.25
, pp. 611-615
-
-
Mathur, A.M.1
Morris, L.D.2
Teteh, F.3
Inder, T.E.4
Zempel, J.5
-
9
-
-
33947186655
-
The use of amplitude-integrated electroencephalography: Beware of its unintended consequences
-
DOI 10.1542/peds.2006-3650
-
Freeman JM. The use of amplitude-integrated electroencephalography: Beware of its unintended consequences. Pediatrics. 2007; 119: 615-17. (Pubitemid 46407560)
-
(2007)
Pediatrics
, vol.119
, Issue.3
, pp. 615-617
-
-
Freeman, J.M.1
-
10
-
-
54049088942
-
Amplitude-integrated electroencephalography in the newborn: A valuable tool
-
Shah DK, de Vries LS, Hellstrom-Westas L, Toet MC, Inder TE. Amplitude-integrated electroencephalography in the newborn: A valuable tool. Pediatrics. 2008; 122: 863-5.
-
(2008)
Pediatrics.
, vol.122
, pp. 863-865
-
-
Shah, D.K.1
De Vries, L.S.2
Hellstrom-Westas, L.3
Toet, M.C.4
Inder, T.E.5
-
11
-
-
0026495071
-
Comparison between tape-recorded and amplitude-integrated EEG monitoring in sick newborn infants
-
Hellström-Westas L. Comparison between tape-recorded and amplitude-integrated EEG monitoring in sick newborn infants. Acta Paediatr. 1992; 81: 812-19.
-
(1992)
Acta Paediatr.
, vol.81
, pp. 812-819
-
-
Hellström-Westas, L.1
-
12
-
-
0036247410
-
Comparison between simultaneously recorded amplitude integrated electroencephalogram (cerebral function monitor) and standard electroencephalogram in neonates
-
DOI 10.1542/peds.109.5.772
-
Toet MC, van der MeijW, de Vries LS, Uiterwaal CS, van Huffelen KC. Comparison between simultaneously recorded amplitude integrated electroencephalogram (cerebral function monitor) and standard electroencephalogram in neonates. Pediatrics. 2002; 109: 772-9. (Pubitemid 34493341)
-
(2002)
Pediatrics
, vol.109
, Issue.5
, pp. 772-779
-
-
Toet, M.C.1
Van Der Meij, W.2
De Vries, L.S.3
Uiterwaal, C.S.P.M.4
Van Huffelen, K.C.5
-
13
-
-
0035143755
-
SNAP-II and SNAPPE-II: Simplified newborn illness severity and mortality risk scores
-
DOI 10.1067/mpd.2001.109608
-
Richardson DK, Corcoran JD, Escobar GJ, Lee SK. SNAP-II and SNAPPE-II: Simplified newborn illness severity and mortality risk scores. J Pediatr. 2001; 138: 92-100. (Pubitemid 32097148)
-
(2001)
Journal of Pediatrics
, vol.138
, Issue.1
, pp. 92-100
-
-
Richardson, D.K.1
Corcoran, J.D.2
Escobar, G.J.3
Lee, S.K.4
-
14
-
-
33745362122
-
Guideline 2: Minimum technical standards for pediatric electoencephalography
-
Guideline 2: Minimum technical standards for pediatric electoencephalography. J Clin Neurophysiol. 2006; 23: 92-6.
-
(2006)
J Clin Neurophysiol.
, vol.23
, pp. 92-96
-
-
-
16
-
-
44049097334
-
Defining the gap between electrographic seizure burden, clinical expression and staff recognition of neonatal seizures
-
DOI 10.1136/adc.2005.086314
-
Murray DM, Boylan GB, Ali I, Ryan CA, Murphy BP, Connolly S. Defining the gap between electrographic seizure burden, clinical expression and staff recognition of neonatal seizures. Arch Dis Child Fetal Neonatal Ed. 2008; 93: F187-91. (Pubitemid 352039284)
-
(2008)
Archives of Disease in Childhood: Fetal and Neonatal Edition
, vol.93
, Issue.3
-
-
Murray, D.M.1
Boylan, G.B.2
Ali, I.3
Ryan, C.A.4
Murphy, B.P.5
Connolly, S.6
-
17
-
-
0038351879
-
Uncoupling of EEG-clinical neonatal seizures after antiepileptic drug use
-
DOI 10.1016/S0887-8994(02)00621-5
-
Scher MS, Alvin J, Gaus L, Minnigh B, Painter MJ. Uncoupling of EEG-clinical neonatal seizures after antiepileptic drug use. Pediatr Neurol. 2003; 28: 277-80. (Pubitemid 36802226)
-
(2003)
Pediatric Neurology
, vol.28
, Issue.4
, pp. 277-280
-
-
Scher, M.S.1
Alvin, J.2
Gaus, L.3
Minnigh, B.4
Painter, M.J.5
-
18
-
-
70449522387
-
Detection of subclinical electroencephalographic seizure patterns with multichannel amplitude-integrated EEG in full-term neonates
-
Bourez-Swart MD, van Rooij L, Rizzo C, et al. Detection of subclinical electroencephalographic seizure patterns with multichannel amplitude-integrated EEG in full-term neonates. Clin Neurophysiol. 2009; 120: 1916-22.
-
(2009)
Clin Neurophysiol.
, vol.120
, pp. 1916-1922
-
-
Bourez-Swart, M.D.1
Van Rooij, L.2
Rizzo, C.3
|