메뉴 건너뛰기




Volumn 59, Issue 10, 2012, Pages 3827-3837

Short-circuit and ground fault analyses and location in VSC-based DC network cables

Author keywords

Fault analysis; fault location; multiterminal dc network; voltage source converter (VSC)

Indexed keywords

CABLES; CAPACITANCE; ELECTRIC FAULT LOCATION; ELECTRIC GROUNDING; LOCATION; TIMING CIRCUITS;

EID: 84860456866     PISSN: 02780046     EISSN: None     Source Type: Journal    
DOI: 10.1109/TIE.2011.2162712     Document Type: Article
Times cited : (807)

References (32)
  • 1
    • 33947651217 scopus 로고    scopus 로고
    • HVDC connection of offshore wind farms to the transmission system
    • Mar.
    • P. Bresesti, W. L. Kling, R. L. Hendriks, and R. Vailati, "HVDC connection of offshore wind farms to the transmission system," IEEE Trans. Energy Convers., vol. 22, no. 1, pp. 37-43, Mar. 2007.
    • (2007) IEEE Trans. Energy Convers. , vol.22 , Issue.1 , pp. 37-43
    • Bresesti, P.1    Kling, W.L.2    Hendriks, R.L.3    Vailati, R.4
  • 4
    • 68349135421 scopus 로고    scopus 로고
    • A novel condition assessment system for underground distribution applications
    • Aug.
    • M. J. Mousavi and K. L. Butler-Purry, "A novel condition assessment system for underground distribution applications," IEEE Trans. Power Syst., vol. 24, no. 3, pp. 1115-1125, Aug. 2009.
    • (2009) IEEE Trans. Power Syst. , vol.24 , Issue.3 , pp. 1115-1125
    • Mousavi, M.J.1    Butler-Purry, K.L.2
  • 6
    • 0014766138 scopus 로고
    • Transient overvoltage on a bipolar HVDC overhead line caused by dc line faults
    • Apr.
    • N. G. Hingorani, "Transient overvoltage on a bipolar HVDC overhead line caused by dc line faults," IEEE Trans. Power App. Syst., vol. PAS-89, no. 4, pp. 592-610, Apr. 1970.
    • (1970) IEEE Trans. Power App. Syst. , vol.PAS-89 , Issue.4 , pp. 592-610
    • Hingorani, N.G.1
  • 7
    • 0014765717 scopus 로고
    • Transient overvoltages caused by monopolar ground fault on bipolar dc line: Theory and simulation
    • Apr.
    • E. W. Kimbark, "Transient overvoltages caused by monopolar ground fault on bipolar dc line: Theory and simulation," IEEE Trans. Power App. Syst., vol. PAS-89, no. 4, pp. 584-592, Apr. 1970.
    • (1970) IEEE Trans. Power App. Syst. , vol.PAS-89 , Issue.4 , pp. 584-592
    • Kimbark, E.W.1
  • 8
    • 0025408406 scopus 로고
    • Transient overvoltages on a three terminal dc transmission system due to monopolar ground faults
    • Apr.
    • G. T. Wrate, I. K. Tasinga, S. S. Low, D. J. Melvold, R. S. Thallam, D. W. Gerlach, and J. Y. Chang, "Transient overvoltages on a three terminal dc transmission system due to monopolar ground faults," IEEE Trans. Power Del., vol. 5, no. 2, pp. 1047-1053, Apr. 1990.
    • (1990) IEEE Trans. Power Del. , vol.5 , Issue.2 , pp. 1047-1053
    • Wrate, G.T.1    Tasinga, I.K.2    Low, S.S.3    Melvold, D.J.4    Thallam, R.S.5    Gerlach, D.W.6    Chang, J.Y.7
  • 9
    • 0028562164 scopus 로고
    • Computerized underground cable fault location expertise
    • Apr. 10-15
    • E. C. Bascom, "Computerized underground cable fault location expertise," in Proc. IEEE Power Eng. Soc. Gen. Meeting, Apr. 10-15, 1994, pp. 376-382.
    • (1994) Proc. IEEE Power Eng. Soc. Gen. Meeting , pp. 376-382
    • Bascom, E.C.1
  • 10
    • 67349134182 scopus 로고    scopus 로고
    • Hybrid travelling wave/boundary protection for monopolar HVDC line
    • Apr.
    • X. Liu, A. H. Osman, and O. P. Malik, "Hybrid travelling wave/boundary protection for monopolar HVDC line," IEEE Trans. Power Del., vol. 24, no. 2, pp. 569-578, Apr. 2009.
    • (2009) IEEE Trans. Power Del. , vol.24 , Issue.2 , pp. 569-578
    • Liu, X.1    Osman, A.H.2    Malik, O.P.3
  • 12
    • 69749118069 scopus 로고    scopus 로고
    • Fault location for underground power cable using distributed parameter approach
    • Nov.
    • X. Yang, M.-S. Choi, S.-J. Lee, C.-W. Ten, and S.-I. Lim, "Fault location for underground power cable using distributed parameter approach," IEEE Trans. Power Syst., vol. 23, no. 4, pp. 1809-1816, Nov. 2008.
    • (2008) IEEE Trans. Power Syst. , vol.23 , Issue.4 , pp. 1809-1816
    • Yang, X.1    Choi, M.-S.2    Lee, S.-J.3    Ten, C.-W.4    Lim, S.-I.5
  • 13
    • 0347968156 scopus 로고    scopus 로고
    • A new fault location algorithm using direct circuit analysis for distribution systems
    • Jan.
    • M.-S. Choi, S.-J. Lee, D.-S. Lee, and B.-G. Jin, "A new fault location algorithm using direct circuit analysis for distribution systems," IEEE Trans. Power Del., vol. 19, no. 1, pp. 35-41, Jan. 2004.
    • (2004) IEEE Trans. Power Del. , vol.19 , Issue.1 , pp. 35-41
    • Choi, M.-S.1    Lee, S.-J.2    Lee, D.-S.3    Jin, B.-G.4
  • 14
    • 79952657384 scopus 로고    scopus 로고
    • Protection scheme design for meshed VSC-HVDC transmission systems for large-scale wind farms
    • London, U.K., Oct. 20-21
    • J. Yang, J. E. Fletcher, and J. O'Reilly, "Protection scheme design for meshed VSC-HVDC transmission systems for large-scale wind farms," in Proc. 9th IET Int. Conf. AC DC Power Transm. (ACDC), London, U.K., Oct. 20-21, 2010, pp. 1-5.
    • (2010) Proc. 9th IET Int. Conf. AC DC Power Transm. (ACDC) , pp. 1-5
    • Yang, J.1    Fletcher, J.E.2    O'Reilly, J.3
  • 15
    • 12544259253 scopus 로고    scopus 로고
    • VSC transmission system operating under unbalanced network conditions-Analysis and control design
    • Jan.
    • L. Xu, B. R. Andersen, and P. Cartwright, "VSC transmission system operating under unbalanced network conditions-Analysis and control design," IEEE Trans. Power Del., vol. 20, no. 1, pp. 427-434, Jan. 2005.
    • (2005) IEEE Trans. Power Del. , vol.20 , Issue.1 , pp. 427-434
    • Xu, L.1    Andersen, B.R.2    Cartwright, P.3
  • 16
    • 70349509225 scopus 로고    scopus 로고
    • Fault ride through of fully rated converter wind turbines with ac and dc transmission systems
    • Aug.
    • G. Ramtharan, A. Arulampalam, J. B. Ekanayake, F. M. Hughes, and N. Jenkins, "Fault ride through of fully rated converter wind turbines with ac and dc transmission systems," IET Renew. Power Gener., vol. 3, no. 4, pp. 426-438, Aug. 2009.
    • (2009) IET Renew. Power Gener. , vol.3 , Issue.4 , pp. 426-438
    • Ramtharan, G.1    Arulampalam, A.2    Ekanayake, J.B.3    Hughes, F.M.4    Jenkins, N.5
  • 18
    • 70349973673 scopus 로고    scopus 로고
    • A literature review of IGBT fault diagnostic and protection methods for power inverters
    • Sep./Oct.
    • B. Lu and S. K. Sharma, "A literature review of IGBT fault diagnostic and protection methods for power inverters," IEEE Trans. Ind. Appl., vol. 45, no. 5, pp. 1770-1777, Sep./Oct. 2009.
    • (2009) IEEE Trans. Ind. Appl. , vol.45 , Issue.5 , pp. 1770-1777
    • Lu, B.1    Sharma, S.K.2
  • 19
    • 77949902437 scopus 로고    scopus 로고
    • Failuremode analysis and protection of three-level neutral-point-clamped PWM voltage source converters
    • Mar./Apr.
    • F.Wang, R. Lai, X. Yuan, F. Luo, R. Burgos, and D. Boroyevich, "Failuremode analysis and protection of three-level neutral-point-clamped PWM voltage source converters," IEEE Trans. Ind. Appl., vol. 46, no. 2, pp. 866-874, Mar./Apr. 2010.
    • (2010) IEEE Trans. Ind. Appl. , vol.46 , Issue.2 , pp. 866-874
    • Wang, F.1    Lai, R.2    Yuan, X.3    Luo, F.4    Burgos, R.5    Boroyevich, D.6
  • 21
    • 67650686103 scopus 로고    scopus 로고
    • Protection of low-voltage dc microgrids
    • Jul.
    • D. Salomonsson, L. Soder, and A. Sannino, "Protection of low-voltage dc microgrids," IEEE Trans. Power Del., vol. 24, no. 3, pp. 1045-1053, Jul. 2009.
    • (2009) IEEE Trans. Power Del. , vol.24 , Issue.3 , pp. 1045-1053
    • Salomonsson, D.1    Soder, L.2    Sannino, A.3
  • 22
    • 1642502394 scopus 로고    scopus 로고
    • DC distribution for industrial systems: Opportunities and challenges
    • Nov./Dec.
    • M. E. Baran and N. R. Mahajan, "DC distribution for industrial systems: Opportunities and challenges," IEEE Trans. Ind. Appl., vol. 39, no. 6, pp. 1596-1601, Nov./Dec. 2003.
    • (2003) IEEE Trans. Ind. Appl. , vol.39 , Issue.6 , pp. 1596-1601
    • Baran, M.E.1    Mahajan, N.R.2
  • 23
    • 34147104446 scopus 로고    scopus 로고
    • Overcurrent protection on voltagesource-converter-based multiterminal DC distribution systems
    • Jan.
    • M. E. Baran and N. R. Mahajan, "Overcurrent protection on voltagesource-converter-based multiterminal DC distribution systems," IEEE Trans. Power Del., vol. 22, no. 1, pp. 406-412, Jan. 2007.
    • (2007) IEEE Trans. Power Del. , vol.22 , Issue.1 , pp. 406-412
    • Baran, M.E.1    Mahajan, N.R.2
  • 24
    • 0030811456 scopus 로고    scopus 로고
    • A new low-cost, fully fault-protected PWM-VSI inverter with true phase-current information
    • Jan.
    • F. Blaabjerg and J. K. Pederson, "A new low-cost, fully fault-protected PWM-VSI inverter with true phase-current information," IEEE Trans. Power Electron., vol. 12, no. 1, pp. 187-197, Jan. 1997.
    • (1997) IEEE Trans. Power Electron. , vol.12 , Issue.1 , pp. 187-197
    • Blaabjerg, F.1    Pederson, J.K.2
  • 25
    • 44449094998 scopus 로고    scopus 로고
    • Locating and isolating DC faults in multi-terminal DC systems
    • Jul.
    • L. Tang and B. T. Ooi, "Locating and isolating DC faults in multi-terminal DC systems," IEEE Trans. Power Del., vol. 22, no. 3, pp. 1877-1884, Jul. 2007.
    • (2007) IEEE Trans. Power Del. , vol.22 , Issue.3 , pp. 1877-1884
    • Tang, L.1    Ooi, B.T.2
  • 26
    • 0036442978 scopus 로고    scopus 로고
    • Protection of VSC-multi-terminal HVDC against DC faults
    • Cairns, Australia, Jun. 23-27
    • L. Tang and B. T. Ooi, "Protection of VSC-multi-terminal HVDC against DC faults," in Proc. IEEE 33rd Annu. Power Electron. Spec. Conf., Cairns, Australia, Jun. 23-27, 2002, vol. 2, pp. 719-724.
    • (2002) Proc. IEEE 33rd Annu. Power Electron. Spec. Conf. , vol.2 , pp. 719-724
    • Tang, L.1    Ooi, B.T.2
  • 28
    • 77956988419 scopus 로고    scopus 로고
    • Multiterminal dc wind farm collection grid internal fault analysis and protection scheme design
    • Oct.
    • J. Yang, J. E. Fletcher, and J. O'Reilly, "Multiterminal dc wind farm collection grid internal fault analysis and protection scheme design," IEEE Trans. Power Del., vol. 25, no. 4, pp. 2308-2318, Oct. 2010.
    • (2010) IEEE Trans. Power Del. , vol.25 , Issue.4 , pp. 2308-2318
    • Yang, J.1    Fletcher, J.E.2    O'Reilly, J.3
  • 30
    • 0036686037 scopus 로고    scopus 로고
    • Multilevel inverters: A survey of topologies, controls, and applications
    • Aug.
    • J. Rodriguez, J.-S. Lai, and F. Z. Peng, "Multilevel inverters: A survey of topologies, controls, and applications," IEEE Trans. Ind. Electron., vol. 49, no. 4, pp. 724-738, Aug. 2002.
    • (2002) IEEE Trans. Ind. Electron. , vol.49 , Issue.4 , pp. 724-738
    • Rodriguez, J.1    Lai, J.-S.2    Peng, F.Z.3
  • 31
    • 0027599356 scopus 로고
    • Overcurrent protection of capacitors applied on industrial distribution systems
    • May/Jun.
    • S. R. Mendis, M. T. Bishop, J. C. McCall, and W. M. Hurst, "Overcurrent protection of capacitors applied on industrial distribution systems," IEEE Trans. Ind. Appl., vol. 29, no. 3, pp. 541-547, May/Jun. 1993.
    • (1993) IEEE Trans. Ind. Appl. , vol.29 , Issue.3 , pp. 541-547
    • Mendis, S.R.1    Bishop, M.T.2    McCall, J.C.3    Hurst, W.M.4
  • 32
    • 0031366623 scopus 로고    scopus 로고
    • Adjustable speed drive neutral voltage shift and grounding issues in a DC distribution system
    • New Orleans, LA, Oct. 5-9
    • K. Xing, F. C. Lee, J. S. Lai, T. Gurjit, and D. Borojevic, "Adjustable speed drive neutral voltage shift and grounding issues in a DC distribution system," in Conf. Rec. IEEE IAS Annu. Meeting, New Orleans, LA, Oct. 5-9, 1997, pp. 517-524.
    • (1997) Conf. Rec. IEEE IAS Annu. Meeting , pp. 517-524
    • Xing, K.1    Lee, F.C.2    Lai, J.S.3    Gurjit, T.4    Borojevic, D.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.