메뉴 건너뛰기




Volumn 138, Issue 14, 2012, Pages 597-601

Measurement of blood pressure in consultation and automated mesurement (BPTru ®) to evaluate the white coat effect;Medida de la presión arterial en consulta y automatizada (BPTru®) para evaluar el efecto de bata blanca

(22)  García Donaire, José Antonio a   Dalfó Baqué, Antoni b   Sanclemente Ansó, Carmen c   Urdiales Castillo, Daniel d   Martínez Debén, Francisco e   Ortega López, Nicolás f   Pizarro Núñez, Juan Luis g   Martín Oterino, José Ángel h   García Norro Herreros, Javier i   Mediavilla García, Juan Diego j   Vara González, Luis Alberto k   Prieto Díaz, Miguel Ángel l   Vila Coll, María Antònia b   Gómez Fernández, Pablo m   Rossique Delmas, Pilar n   Gascón Becerril, Ramón o   Pérez Álvarez, Roberto p   Delgado Zamora, Rodrigo q   De Vega Santos, Tomás r   Cerezo Olmos, Cesar a   more..


Author keywords

Automated device; Blood pressure; BPTru ; White coat effect

Indexed keywords

ARTICLE; AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT; AUTOMATION; BLOOD PRESSURE MEASUREMENT; CLINICAL ASSESSMENT; CONSULTATION; HUMAN; HYPERTENSION; MAJOR CLINICAL STUDY; SPHYGMOMANOMETER; WHITE COAT EFFECT;

EID: 84860448803     PISSN: 00257753     EISSN: 15788989     Source Type: Journal    
DOI: 10.1016/j.medcli.2011.10.030     Document Type: Article
Times cited : (6)

References (24)
  • 1
    • 0031961190 scopus 로고    scopus 로고
    • Systolic blood pressure, isolated systolic hypertension and risk of coronary heart disease, strokes, cardiovascular disease and all-cause mortality in the middle-aged population
    • R. Antikainen, P. Jousilahti, and J. Tuomilehto Systolic blood pressure, isolated systolic hypertension and risk of coronary heart disease, strokes, cardiovascular disease and all-cause mortality in the middle-aged population J Hypertens 16 1998 577 583
    • (1998) J Hypertens , vol.16 , pp. 577-583
    • Antikainen, R.1    Jousilahti, P.2    Tuomilehto, J.3
  • 2
    • 0023833821 scopus 로고
    • Mortality associated with diastolic hypertension and isolated systolic hypertension among men screened for the Multiple Risk Factor Intervention Trial
    • G.H. Rutan, L.H. Kuller, J.D. Neaton, D.N. Wentworth, R.H. McDonald, and W.M. Smith Mortality associated with diastolic hypertension and isolated systolic hypertension among men screened for the Multiple Risk Factor Intervention Trial Circulation 77 1988 504 514
    • (1988) Circulation , vol.77 , pp. 504-514
    • Rutan, G.H.1    Kuller, L.H.2    Neaton, J.D.3    Wentworth, D.N.4    McDonald, R.H.5    Smith, W.M.6
  • 3
    • 34548623235 scopus 로고    scopus 로고
    • 2007 ESH-ESC Guidelines for the management of arterial hypertension: The task force for the management of arterial hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC)
    • European Society of Hypertension; European Society of Cardiology
    • G. Mancia, G. De Backer, A. Dominiczak, R. Cifkova, R. Fagard, G. Germano European Society of Hypertension; European Society of Cardiology 2007 ESH-ESC Guidelines for the management of arterial hypertension: the task force for the management of arterial hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC) Blood Press 16 2007 135 232
    • (2007) Blood Press , vol.16 , pp. 135-232
    • Mancia, G.1    De Backer, G.2    Dominiczak, A.3    Cifkova, R.4    Fagard, R.5    Germano, G.6
  • 4
    • 0347423198 scopus 로고    scopus 로고
    • Seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure
    • Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. National Heart, Lung, and Blood Institute; National High Blood Pressure Education Program Coordinating Committee
    • A.V. Chobanian, G.L. Bakris, H.R. Black, W.C. Cushman, L.A. Green, J.L. Izzo Jr. Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure. National Heart, Lung, and Blood Institute; National High Blood Pressure Education Program Coordinating Committee Seventh report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure Hypertension 42 2003 1206 1252
    • (2003) Hypertension , vol.42 , pp. 1206-1252
    • Chobanian, A.V.1    Bakris, G.L.2    Black, H.R.3    Cushman, W.C.4    Green, L.A.5    Izzo, Jr.J.L.6
  • 5
    • 12344259499 scopus 로고    scopus 로고
    • World health organisation-international society of hypertension (WHO/ISH) hypertension guidelines
    • J.A. Whitworth, and J. Chalmers World health organisation-international society of hypertension (WHO/ISH) hypertension guidelines Clin Exp Hypertens 26 2004 747 752
    • (2004) Clin Exp Hypertens , vol.26 , pp. 747-752
    • Whitworth, J.A.1    Chalmers, J.2
  • 6
    • 59849115803 scopus 로고    scopus 로고
    • Should doctors still measure blood pressure? the missing patients with masked hypertension
    • T.G. Pickering, W. Gerin, J.E. Schwartz, T.M. Spruill, and K.W. Davidson Should doctors still measure blood pressure? The missing patients with masked hypertension J Hypertens 26 2008 2259 2267
    • (2008) J Hypertens , vol.26 , pp. 2259-2267
    • Pickering, T.G.1    Gerin, W.2    Schwartz, J.E.3    Spruill, T.M.4    Davidson, K.W.5
  • 7
    • 68949136922 scopus 로고    scopus 로고
    • Why is out-of-office blood pressure measurement needed?
    • G. Parati, S. Omboni, and G. Bilo Why is out-of-office blood pressure measurement needed? Hypertension 54 2009 181 187
    • (2009) Hypertension , vol.54 , pp. 181-187
    • Parati, G.1    Omboni, S.2    Bilo, G.3
  • 8
    • 84860498039 scopus 로고    scopus 로고
    • Self measurement of blood pressure at home should complement rather than replace office blood pressure management
    • M.J. Bloch, and J.N. Basile Self measurement of blood pressure at home should complement rather than replace office blood pressure management J Clin Hypertens (Greenwich) 10 2008 324 326
    • (2008) J Clin Hypertens (Greenwich) , vol.10 , pp. 324-326
    • Bloch, M.J.1    Basile, J.N.2
  • 9
    • 68749099660 scopus 로고    scopus 로고
    • Home blood pressure measurements will not replace 24-hour ambulatory blood pressure monitoring
    • P. Verdecchia, F. Angeli, G. Mazzota, G. Gentile, and G. Reboldi Home blood pressure measurements will not replace 24-hour ambulatory blood pressure monitoring Hypertension 54 2009 188 195
    • (2009) Hypertension , vol.54 , pp. 188-195
    • Verdecchia, P.1    Angeli, F.2    Mazzota, G.3    Gentile, G.4    Reboldi, G.5
  • 10
    • 74949121981 scopus 로고    scopus 로고
    • Measurement of blood pressure in the office: Recognizing the problem and proposing the solution
    • M. Myers, M. Godwin, M. Dawes, A. Kiss, S. Tobe, and J. Kaczorowski Measurement of blood pressure in the office: recognizing the problem and proposing the solution Hypertension 55 2010 195 200
    • (2010) Hypertension , vol.55 , pp. 195-200
    • Myers, M.1    Godwin, M.2    Dawes, M.3    Kiss, A.4    Tobe, S.5    Kaczorowski, J.6
  • 11
    • 0029063986 scopus 로고
    • Prevalence of white coat effect in treated hypertensive patients in the community
    • M.G. Myers, P. Oh, R.A. Reeves, and C.D. Joyner Prevalence of white coat effect in treated hypertensive patients in the community Am J Hypertens 8 1995 591 597
    • (1995) Am J Hypertens , vol.8 , pp. 591-597
    • Myers, M.G.1    Oh, P.2    Reeves, R.A.3    Joyner, C.D.4
  • 12
    • 0035216183 scopus 로고    scopus 로고
    • Is resistant hypertension really resistant?
    • M.A. Brown, M.L. Buddle, and A. Martin Is resistant hypertension really resistant? Am J Hypertens 14 2001 1263 1269
    • (2001) Am J Hypertens , vol.14 , pp. 1263-1269
    • Brown, M.A.1    Buddle, M.L.2    Martin, A.3
  • 14
    • 33745476013 scopus 로고    scopus 로고
    • How long shall the patient rest before clinic blood pressure measurement?
    • C. Sala, A. Santin, M. Rescaldani, and F. Magrini How long shall the patient rest before clinic blood pressure measurement? Am J Hypertens 19 2006 713 717
    • (2006) Am J Hypertens , vol.19 , pp. 713-717
    • Sala, C.1    Santin, A.2    Rescaldani, M.3    Magrini, F.4
  • 15
    • 0034959116 scopus 로고    scopus 로고
    • Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults
    • W.G. White, and Y.A. Anwar Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults Blood Press Monit 6 2001 107 110
    • (2001) Blood Press Monit , vol.6 , pp. 107-110
    • White, W.G.1    Anwar, Y.A.2
  • 16
    • 45849089534 scopus 로고    scopus 로고
    • Ambulatory blood pressure measurement: The case for implementation in primary care
    • E. O'Brien Ambulatory blood pressure measurement: the case for implementation in primary care Hypertension 51 2008 1435 1441
    • (2008) Hypertension , vol.51 , pp. 1435-1441
    • O'Brien, E.1
  • 17
    • 70449628906 scopus 로고    scopus 로고
    • Differences between office and ambulatory control of hypertension in very elderly patients. The CARDIORISC-MAPAPRES project
    • en representación de los investigadores del Proyecto CARDIORISC-MAPAPRES. Sociedad Española de Hipertensión-Liga Española para la Lucha contra la Hipertensión Arterial (SEH-LELHA)
    • J.L. Llisterri, F.J. Alonso, M. Gorostidi, C. Sierra, A. de la Sierra, J.R. Banegas en representación de los investigadores del Proyecto CARDIORISC-MAPAPRES. Sociedad Española de Hipertensión-Liga Española para la Lucha contra la Hipertensión Arterial (SEH-LELHA) Differences between office and ambulatory control of hypertension in very elderly patients. The CARDIORISC-MAPAPRES project Med Clin (Barc) 133 2009 769 776
    • (2009) Med Clin (Barc) , vol.133 , pp. 769-776
    • Llisterri, J.L.1    Alonso, F.J.2    Gorostidi, M.3    Sierra, C.4    De La Sierra, A.5    Banegas, J.R.6
  • 18
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • J.M. Bland, and D.G. Altman Statistical methods for assessing agreement between two methods of clinical measurement Lancet 1 1986 307 310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 57149138712 scopus 로고    scopus 로고
    • Optimum frequency of automated blood pressure measurements using an automated sphygmomanometer
    • M.G. Myers, M. Valdivieso, and A. Kiss Optimum frequency of automated blood pressure measurements using an automated sphygmomanometer Blood Press Monit 13 2008 333 338
    • (2008) Blood Press Monit , vol.13 , pp. 333-338
    • Myers, M.G.1    Valdivieso, M.2    Kiss, A.3
  • 20
    • 63849254204 scopus 로고    scopus 로고
    • Use of automated office blood pressure measurement to reduce the white coat response
    • M.G. Myers, M. Valdivieso, and A. Kiss Use of automated office blood pressure measurement to reduce the white coat response J Hypertens 27 2009 280 286
    • (2009) J Hypertens , vol.27 , pp. 280-286
    • Myers, M.G.1    Valdivieso, M.2    Kiss, A.3
  • 21
    • 0347601672 scopus 로고    scopus 로고
    • Clinical decision-making in hypertension using an automated (BpTRU) measurement device
    • J.W. Graves, C. Nash, K. Burger, K. Bailey, and S.G. Sheps Clinical decision-making in hypertension using an automated (BpTRU) measurement device J Hum Hypertens 17 2003 823 827
    • (2003) J Hum Hypertens , vol.17 , pp. 823-827
    • Graves, J.W.1    Nash, C.2    Burger, K.3    Bailey, K.4    Sheps, S.G.5
  • 22
    • 0348231661 scopus 로고    scopus 로고
    • White coat hypertension is a cardiovascular risk factor: A 10-year follow-up study
    • P.H. Gustavsen, A. Hoegholm, L.E. Bang, and K.S. Kristensen White coat hypertension is a cardiovascular risk factor: a 10-year follow-up study J Hum Hypertens 17 2003 811 817
    • (2003) J Hum Hypertens , vol.17 , pp. 811-817
    • Gustavsen, P.H.1    Hoegholm, A.2    Bang, L.E.3    Kristensen, K.S.4
  • 23
    • 26844562540 scopus 로고    scopus 로고
    • The BpTRU automatic blood pressure monitor compared to 24-h ambulatory blood pressure monitoring in the assessment of blood pressure in patients with hypertension
    • L. Beckett, and M. Godwin The BpTRU automatic blood pressure monitor compared to 24-h ambulatory blood pressure monitoring in the assessment of blood pressure in patients with hypertension BMC Cardiovasc Disord 5 2005 18
    • (2005) BMC Cardiovasc Disord , vol.5 , pp. 18
    • Beckett, L.1    Godwin, M.2
  • 24
    • 33746152724 scopus 로고    scopus 로고
    • Daytime ambulatory systolic blood pressure is more effective at predicting mortality than clinic blood pressure
    • M.G. Dawes, A.J. Coats, and E. Juszczak Daytime ambulatory systolic blood pressure is more effective at predicting mortality than clinic blood pressure Blood Press Monit 11 2006 111 118
    • (2006) Blood Press Monit , vol.11 , pp. 111-118
    • Dawes, M.G.1    Coats, A.J.2    Juszczak, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.