메뉴 건너뛰기




Volumn 28, Issue 3, 2003, Pages 161-182

An application framework for computer-aided patient positioning in radiation therapy

Author keywords

Optical tracking; Patient positioning; Radiotherapy; Software framework

Indexed keywords

ACCURACY; ARTICLE; CASE REPORT; COMPUTER ASSISTED RADIOTHERAPY; COMPUTER LANGUAGE; COMPUTER PROGRAM; CONTROLLED STUDY; DEVICE; HUMAN; IMAGE SUBTRACTION; OPTICS; PATIENT POSITIONING; TREATMENT PLANNING; VIDEOTAPE;

EID: 84860420144     PISSN: 14639238     EISSN: None     Source Type: Journal    
DOI: 10.1080/14639230310001613458     Document Type: Article
Times cited : (7)

References (29)
  • 2
    • 0003651542 scopus 로고    scopus 로고
    • Prescribing, Recording and Reporting Photon Beam Therapy
    • International Commission on Radiation Units and Measurements (ICRU)
    • International Commission on Radiation Units and Measurements (ICRU). Prescribing, Recording and Reporting Photon Beam Therapy. ICRU Report 50.
    • ICRU Report 50
  • 4
    • 0028027605 scopus 로고
    • Influence of the positioning error on 3D conformal dose distribution during fractionated radiotherapy
    • Rudat, V., Flentje, M., Oetzel, D., Menke, M., Schlegel, W. and Wannenmacher, M., 1994, Influence of the positioning error on 3D conformal dose distribution during fractionated radiotherapy. Radiotherapy and Oncology, 33, 56-63.
    • (1994) Radiotherapy and Oncology , vol.33 , pp. 56-63
    • Rudat, V.1    Flentje, M.2    Oetzel, D.3    Menke, M.4    Schlegel, W.5    Wannenmacher, M.6
  • 8
    • 0344375860 scopus 로고    scopus 로고
    • Spezifikation und Implementierung eines videobasierten Systems zur Patientenpositionierung in der Präzisionsstrahlentherapie
    • PhD thesis, Medical Faculty of the Heidelberg University, Heidelberg, Germany
    • Lappe, C., 1999, Spezifikation und Implementierung eines videobasierten Systems zur Patientenpositionierung in der Präzisionsstrahlentherapie, PhD thesis, Medical Faculty of the Heidelberg University, Heidelberg, Germany.
    • (1999)
    • Lappe, C.1
  • 14
    • 0345670464 scopus 로고    scopus 로고
    • Patientenpositionierung für die konformierende Strahlentherapie im Kopf-Hals Bereich
    • (DGMP'98, Dresden. October 1998)
    • Kuhr, G., Lappe, C. and Schlegel, W., 1998, Patientenpositionierung für die konformierende Strahlentherapie im Kopf-Hals Bereich. Proceedings of Medizinische Physik 98 (DGMP'98, Dresden. October 1998) pp. 237-238.
    • (1998) Proceedings of Medizinische Physik 98 , pp. 237-238
    • Kuhr, G.1    Lappe, C.2    Schlegel, W.3
  • 15
    • 0345670463 scopus 로고    scopus 로고
    • Entwicklung und klinische Testung einer Methode zur Dento-maxillaren Fixation eines Markersystems zur Verifizierung exakter Patienten-Repositionierung bei fraktionierten stereotaktischen Behandlungen
    • Unpublished PhD thesis, Medical Faculty of the Saarland University, Saarbrücken, Germany
    • Braun, M., 1997, Entwicklung und klinische Testung einer Methode zur Dento-maxillaren Fixation eines Markersystems zur Verifizierung exakter Patienten-Repositionierung bei fraktionierten stereotaktischen Behandlungen, Unpublished PhD thesis, Medical Faculty of the Saarland University, Saarbrücken, Germany.
    • (1997)
    • Braun, M.1
  • 17
    • 0345670465 scopus 로고    scopus 로고
    • Ein optisches Messsystem zur Patientenpositionierung in der Präzisionsstrahlentherapie von Tumoren
    • PhD thesis, Faculty of Physics and Astronomy of the Heidelberg University, Heidelberg, Germany
    • Kuhr, G., 2000, Ein optisches Messsystem zur Patientenpositionierung in der Präzisionsstrahlentherapie von Tumoren. PhD thesis, Faculty of Physics and Astronomy of the Heidelberg University, Heidelberg, Germany.
    • (2000)
    • Kuhr, G.1
  • 22
    • 0003624662 scopus 로고    scopus 로고
    • Object Management Group (OMG), Version 1.4
    • Object Management Group (OMG), 2001, OMG Unified Modeling Language Specification, Version 1.4. http://www.omg.org/uml
    • (2001) OMG Unified Modeling Language Specification
  • 27
    • 0027172788 scopus 로고
    • Three-dimensional verification of patient placement during radiotherapy using portal images
    • Bijhold, J., 1994, Three-dimensional verification of patient placement during radiotherapy using portal images. Journal of Medical Physics, 20, 347-356.
    • (1994) Journal of Medical Physics , vol.20 , pp. 347-356
    • Bijhold, J.1
  • 29
    • 0345670466 scopus 로고    scopus 로고
    • National Electrical Manufacturers Association (NEMA)
    • National Electrical Manufacturers Association (NEMA), 1999, DICOM in Radiotherapy. http://www.nema.org
    • (1999) DICOM in Radiotherapy


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.