메뉴 건너뛰기




Volumn 72, Issue SUPPL. 243, 2012, Pages 32-40

Vitamin D status as an international issue: National surveys and the problem of standardization

Author keywords

25 hydroxyvitamin D; 3 epi 25 hydroxyvitamin D; Calibration; CAP; CLSI; Commutability; DEQAS; Harmonization; NIST; Standardization; Traceability

Indexed keywords

25 HYDROXYVITAMIN D; FRESH FROZEN PLASMA; 25-HYDROXYVITAMIN D; DRUG DERIVATIVE; VITAMIN D;

EID: 84860380168     PISSN: 00365513     EISSN: 15027686     Source Type: Journal    
DOI: 10.3109/00365513.2012.681935     Document Type: Article
Times cited : (309)

References (29)
  • 1
    • 78650887156 scopus 로고    scopus 로고
    • Accuracy of 25-hydroxyvitamin d assays: Confronting the issues
    • Carter GD. Accuracy of 25-hydroxyvitamin D assays: Confronting the issues. Current Drug Targets 2011;12: 19-28.
    • (2011) Current Drug Targets , Issue.12 , pp. 19-28
    • Carter, G.D.1
  • 2
    • 77951097205 scopus 로고    scopus 로고
    • Measurement of 25-hydroxyvitamin d in the clinical laboratory: Current procedures, performance characteristics and limitations
    • Wallace Am, Gibson S, de la Hunty A, Lamberg-Allardt, Ashwell M. Measurement of 25-hydroxyvitamin D in the clinical laboratory: Current procedures, performance characteristics and limitations. Steroids 2010;75:477-488.
    • (2010) Steroids , vol.75 , pp. 477-488
    • Am, W.1    Gibson, S.2    De La Hunty, A.3    Lamberg-Allardt4    Ashwell, M.5
  • 3
    • 84870847302 scopus 로고    scopus 로고
    • IOM (Institute of Medicine Dietary Reference Intakes for Calcium and Vitamin D Washington, DC. The National Academies Press. 2011.
    • IOM (Institute of Medicine). Dietary Reference Intakes for Calcium and Vitamin D. Washington, DC. The National Academies Press. 2011.
  • 4
    • 77749324101 scopus 로고    scopus 로고
    • Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin d3 and 25-hydroxyvitamin d2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry
    • Tai SS-C, Bedner M, Phinney KW. Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry. Anal Chem 2010;82:1942-1948.
    • (2010) Anal Chem , vol.82 , pp. 1942-1948
    • Tai, S.S.-C.1    Bedner, M.2    Phinney, K.W.3
  • 5
    • 79952205543 scopus 로고    scopus 로고
    • Candidate reference measurement procedures for serum 25-hydroxyvitamin d3 and 25-hydroxyvitamin d2 by using isotope-dilution liquid chromatography-tandem mass spectrometry
    • Stepman HCM, Vanderroost A, Van Uytfanghe K, Thienpont LM. Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotope-dilution liquid chromatography-tandem mass spectrometry. Clin Chem 2011;57:441-448.
    • (2011) Clin Chem , Issue.57 , pp. 441-448
    • Stepman, H.C.M.1    Vanderroost, A.2    Van Uytfanghe, K.3    Thienpont, L.M.4
  • 6
    • 79952090403 scopus 로고    scopus 로고
    • Full-scan mass spectral evidence fo 3-epi-25-hydroxyvitamin d3 in serum and infants
    • Stepman HCM, Vanderroost A, Stöckl D, Thienpont LM. Full-scan mass spectral evidence fo 3-epi-25-hydroxyvitamin D3 in serum and infants. Clin Chem Lab Med 2011;49: 253-256.
    • (2011) Clin Chem Lab Med , vol.49 , pp. 253-256
    • Stepman, H.C.M.1    Vanderroost, A.2    Stöckl, D.3    Thienpont, L.M.4
  • 10
    • 84859544312 scopus 로고    scopus 로고
    • Serum 24,25-dihydroxyvitamin d concentrations in osteogenesis imperfect: Relations to bone parameters
    • First published ahead of print as doi:10.1210/jc.2011-3015
    • Edouard T, Husseini A, Glorieux FH, Rauch F. Serum 24,25-dihydroxyvitamin D concentrations in osteogenesis imperfect: relations to bone parameters. J Clin Endocrin Metab. First published ahead of print as doi:10.1210/jc.2011-3015
    • J Clin Endocrin Metab
    • Edouard, T.1    Husseini, A.2    Glorieux, F.H.3    Rauch, F.4
  • 11
    • 84856023348 scopus 로고    scopus 로고
    • Cdc cholesterol standardization program celebrates 50 years of service
    • Cooper GR. CDC Cholesterol Standardization Program celebrates 50 years of service. Clinical Laboratory News 2008;34:14.
    • (2008) Clinical Laboratory News , vol.34 , pp. 14
    • Cooper, G.R.1
  • 12
    • 0033756323 scopus 로고    scopus 로고
    • A reference method laboratory network for cholesterol: A model for standardization and improvement of clinical laboratory measurements
    • Myers GL, Kimberly MM, Waymack PP, Smith SJ, Cooper GR, Sampson EJ. A reference method laboratory network for cholesterol: A model for standardization and improvement of clinical laboratory measurements. Clin Chem 2000; 46:1762-1772.
    • (2000) Clin Chem , vol.46 , pp. 1762-1772
    • Myers, G.L.1    Kimberly, M.M.2    Waymack, P.P.3    Smith, S.J.4    Cooper, G.R.5    Sampson, E.J.6
  • 14
    • 77955428229 scopus 로고    scopus 로고
    • Standardization of testosterone measurements in humans
    • Vesper HW, Botelho JC. Standardization of testosterone measurements in humans. J Steriod Biochem Mol Biol 2010;121:513-519.
    • (2010) J Steriod Biochem Mol Biol , vol.121 , pp. 513-519
    • Vesper, H.W.1    Botelho, J.C.2
  • 16
    • 66549112943 scopus 로고    scopus 로고
    • Traceability in laboratory medicine
    • Vesper HW, Thienpont LM. Traceability in laboratory medicine. Clin Chem 2009;55:1067-1075.
    • (2009) Clin Chem , vol.55 , pp. 1067-1075
    • Vesper, H.W.1    Thienpont, L.M.2
  • 17
    • 84870791355 scopus 로고    scopus 로고
    • NIST Vitamin D Metabolites Quality Assurance Program (accessed on March 21, 2012)
    • NIST Vitamin D Metabolites Quality Assurance Program: http://www.nist.gov/mml/analytical/vitdqap.cfm (accessed on March 21, 2012).
  • 19
    • 0019929673 scopus 로고
    • Methodological considerations of the national health and nutrition examination survey
    • Murphy Rs, Michael GA. Methodological considerations of the National Health and Nutrition Examination Survey. Am J Clin Nutr 1982;35:1255-1258.
    • (1982) Am J Clin Nutr , vol.35 , pp. 1255-1258
    • Murphy, Rs.1    Michael, G.A.2
  • 21
    • 77952308357 scopus 로고    scopus 로고
    • Vitamin d status of canadians as measured in the 2007 to 2009 canadian health measures survey
    • Langlois K, Greene-Finestone L, Little J, Hidiroglou N, Whiting S. Vitamin D status of Canadians as measured in the 2007 to 2009 Canadian Health Measures Survey. Health Reports 2010;21:47-55.
    • (2010) Health Reports , vol.21 , pp. 47-55
    • Langlois, K.1    Greene-Finestone, L.2    Little, J.3    Hidiroglou, N.4    Whiting, S.5
  • 23
    • 84870815070 scopus 로고    scopus 로고
    • NCCLS. Method comparison and bias estimation using patient samples; Approved guideline-Second Edition. NCCLS document EP9-A2 (ISBN 1-56238-392-2). NCCLS, Clinical and Laboratory Standards Institute. 950 West Valley Road, Suite 2500 Wayne, PA 19087 USA, 2002.
    • NCCLS. Method comparison and bias estimation using patient samples; Approved guideline-Second Edition. NCCLS document EP9-A2 (ISBN 1-56238-392-2). NCCLS, Clinical and Laboratory Standards Institute. 950 West Valley Road, Suite 2500 Wayne, PA 19087 USA, 2002.
  • 24
    • 69849088055 scopus 로고    scopus 로고
    • Specifications for trueness and precision of a reference measurement system for serum/plasma 25-hydroxyvitamin d analysis
    • Stöckl D, Sluss PM, Thienpont LM. Specifications for trueness and precision of a reference measurement system for serum/plasma 25-hydroxyvitamin D analysis. Clin Chem Acta 2009;408:8-13.
    • (2009) Clin Chem Acta , vol.408 , pp. 8-13
    • Stöckl, D.1    Sluss, P.M.2    Thienpont, L.M.3
  • 25
    • 84870777392 scopus 로고    scopus 로고
    • NCCLS. Preparation and validation of commutable frozen human serum pools as secondary reference materials for cholesterol measurement procedures; approved guidelines. NCCLS document C37-A (ISBN 1-56238-392-2). NCCLS, Clinical and Laboratory Standards Institute. 950 West Valley Road, Suite 2500 Wayne, PA 19087 USA, 1999.
    • NCCLS. Preparation and validation of commutable frozen human serum pools as secondary reference materials for cholesterol measurement procedures; approved guidelines. NCCLS document C37-A (ISBN 1-56238-392-2). NCCLS, Clinical and Laboratory Standards Institute. 950 West Valley Road, Suite 2500 Wayne, PA 19087 USA, 1999.
  • 26
    • 41849136467 scopus 로고    scopus 로고
    • Measurement of 25-hydroxyvitamin d3 (25ohd3) and 25-hydroxyvitamin d2 (25ohd2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method
    • Chen H, McCoy LF, Schleicher RL, Pfeiffer CM. Measurement of 25-hydroxyvitamin D3 (25OHD3) and 25-hydroxyvitamin D2 (25OHD2) in human serum using liquid chromatography-tandem mass spectrometry and its comparison to a radioimmunoassay method. Clin Chim Acta 2008;391:6-12.
    • (2008) Clin Chim Acta , vol.391 , pp. 6-12
    • Chen, H.1    McCoy, L.F.2    Schleicher, R.L.3    Pfeiffer, C.M.4
  • 28
    • 82755167810 scopus 로고    scopus 로고
    • Profi-ciency testing/external quality assessment: Current challenges and future directions
    • Miller WG, Jones GRD, Horowitz GL, Weykamp C. Profi-ciency testing/external quality assessment: Current challenges and future directions. Clin Chem 2011;57:1670-1680.
    • (2011) Clin Chem , Issue.57 , pp. 1670-1680
    • Miller, W.G.1    Jones, G.R.D.2    Horowitz, G.L.3    Weykamp, C.4
  • 29
    • 84870844457 scopus 로고    scopus 로고
    • Clinical and Laboratory Standards Institute (CLSI Characterization and qualification of commutable reference materials for laboratory medicine; Approved guideline. CLSI document C53-A (ISBN 1-56238-726-X). Clinical and Laboratory Standards Institute. 950 West Valley Road, Suite 2500 Wayne, PA 19087 USA 2010
    • Clinical and Laboratory Standards Institute (CLSI). Characterization and qualification of commutable reference materials for laboratory medicine; Approved guideline. CLSI document C53-A (ISBN 1-56238-726-X). Clinical and Laboratory Standards Institute. 950 West Valley Road, Suite 2500 Wayne, PA 19087 USA 2010.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.