메뉴 건너뛰기




Volumn 55, Issue 5, 2012, Pages 1410-1418

Endovascular creation of aortic dissection in a swine model with technical considerations

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; AORTA DISSECTION; AORTOGRAPHY; ARTERIAL WALL THICKNESS; ARTICLE; BLOOD VESSEL INJURY; CATHETER; CONE BEAM COMPUTED TOMOGRAPHY; CONTROLLED STUDY; ENDOVASCULAR SURGERY; FEMALE; FEMORAL ARTERY; FLUOROSCOPY; GUIDE WIRE; HISTOPATHOLOGY; MINIMALLY INVASIVE SURGERY; NONHUMAN; PRIORITY JOURNAL; SWINE; THORACOABDOMINAL AORTA ANEURYSM; VASCULAR PATENCY;

EID: 84860354997     PISSN: 07415214     EISSN: 10976809     Source Type: Journal    
DOI: 10.1016/j.jvs.2011.10.088     Document Type: Article
Times cited : (32)

References (24)
  • 2
    • 39249085990 scopus 로고    scopus 로고
    • Outcomes and survival in surgical treatment of descending thoracic aorta with acute dissection
    • J. Bozinovski, J.S. Coselli Outcomes and survival in surgical treatment of descending thoracic aorta with acute dissection Ann Thorac Surg 85 2008 965 970
    • (2008) Ann Thorac Surg , vol.85 , pp. 965-970
    • Bozinovski, J.1    Coselli, J.S.2
  • 3
    • 33747172006 scopus 로고    scopus 로고
    • Role and results of surgery in acute type B aortic dissection: Insights from the International Registry of Acute Aortic Dissection (IRAD)
    • S. Trimarchi, C.A. Nienaber, V. Rampoldi, T. Myrmel, T. Suzuki, E. Bossone Role and results of surgery in acute type B aortic dissection: insights from the International Registry of Acute Aortic Dissection (IRAD) Circulation 114 2006 1357 1364
    • (2006) Circulation , vol.114 , pp. 1357-1364
    • Trimarchi, S.1    Nienaber, C.A.2    Rampoldi, V.3    Myrmel, T.4    Suzuki, T.5    Bossone, E.6
  • 4
    • 79952532953 scopus 로고    scopus 로고
    • Thoracic aortic stent-grafting for acute, complicated, type B aortic dissections
    • S.W. Ham, V.L. Rowe, C. Ochoa, T. Chong, W.M. Lee, C.J. Baker Thoracic aortic stent-grafting for acute, complicated, type B aortic dissections Ann Vasc Surg 25 2011 333 339
    • (2011) Ann Vasc Surg , vol.25 , pp. 333-339
    • Ham, S.W.1    Rowe, V.L.2    Ochoa, C.3    Chong, T.4    Lee, W.M.5    Baker, C.J.6
  • 5
    • 76549120518 scopus 로고    scopus 로고
    • Midterm results for endovascular repair of complicated acute and chronic type B aortic dissection
    • C.J. Parsa, J.N. Schroder, M.A. Daneshmand, R.L. Mccann, G.C. Hughes Midterm results for endovascular repair of complicated acute and chronic type B aortic dissection Ann Thorac Surg 89 2010 97 102
    • (2010) Ann Thorac Surg , vol.89 , pp. 97-102
    • Parsa, C.J.1    Schroder, J.N.2    Daneshmand, M.A.3    McCann, R.L.4    Hughes, G.C.5
  • 6
    • 80054850606 scopus 로고    scopus 로고
    • Technical and clinical success after endovascular therapy for chronic type B aortic dissections
    • [Epub ahead of print]
    • A. Oberhuber, P. Winkle, H. Schelzig, K.H. Orend, B.M. Muehling Technical and clinical success after endovascular therapy for chronic type B aortic dissections J Vasc Surg 2011 [Epub ahead of print]
    • (2011) J Vasc Surg
    • Oberhuber, A.1    Winkle, P.2    Schelzig, H.3    Orend, K.H.4    Muehling, B.M.5
  • 7
    • 79951855796 scopus 로고    scopus 로고
    • Intraoperative C-arm cone-beam computed tomography in fenestrated/branched aortic endografting
    • M.L. Dijkstra, M.J. Eagleton, R.K. Greenberg, T. Mastracci, A. Hernandez Intraoperative C-arm cone-beam computed tomography in fenestrated/branched aortic endografting J Vasc Surg 53 2011 583 590
    • (2011) J Vasc Surg , vol.53 , pp. 583-590
    • Dijkstra, M.L.1    Eagleton, M.J.2    Greenberg, R.K.3    Mastracci, T.4    Hernandez, A.5
  • 8
    • 41649112605 scopus 로고    scopus 로고
    • Endovascular management of thoracic dissections
    • W. Swee, M.D. Dake Endovascular management of thoracic dissections Circulation 117 2008 1460 1473
    • (2008) Circulation , vol.117 , pp. 1460-1473
    • Swee, W.1    Dake, M.D.2
  • 9
    • 19244368327 scopus 로고    scopus 로고
    • Treatment of acute Stanford type B aortic dissection with a novel cylindrical balloon catheter in dogs
    • H. Terai, N. Tamura, T. Nakamura, K. Nishimura, N. Tsutsui, Y. Shimizu Treatment of acute Stanford type B aortic dissection with a novel cylindrical balloon catheter in dogs Circulation 102 2000 259 262
    • (2000) Circulation , vol.102 , pp. 259-262
    • Terai, H.1    Tamura, N.2    Nakamura, T.3    Nishimura, K.4    Tsutsui, N.5    Shimizu, Y.6
  • 11
    • 0029202852 scopus 로고
    • Use of a balloon-expandable intravascular graft in the management of type B aortic dissection in an animal model
    • C.H. Marty-Ané, O. SerreCousiné, J.C. Laborde, V. Costes, H. Mary, J.P. Senac Use of a balloon-expandable intravascular graft in the management of type B aortic dissection in an animal model J Vasc Interv Radiol 6 1995 97 103
    • (1995) J Vasc Interv Radiol , vol.6 , pp. 97-103
    • Marty-Ané, C.H.1    Serrecousiné, O.2    Laborde, J.C.3    Costes, V.4    Mary, H.5    Senac, J.P.6
  • 12
    • 0028961916 scopus 로고
    • Experimental assessment of newly devised transcatheter stent graft for aortic dissection
    • M. Kato, T. Matsuda, M. Kaneko, T. Ueda, T. Kuratani, Y. Yoshioka Experimental assessment of newly devised transcatheter stent graft for aortic dissection Ann Thorac Surg 59 1995 908 915
    • (1995) Ann Thorac Surg , vol.59 , pp. 908-915
    • Kato, M.1    Matsuda, T.2    Kaneko, M.3    Ueda, T.4    Kuratani, T.5    Yoshioka, Y.6
  • 13
    • 0027944311 scopus 로고
    • New approach to aortic dissection: Development of an insertable aortic prosthesis
    • H. Yoshida, K. Yasuda, T. Tanabe New approach to aortic dissection: development of an insertable aortic prosthesis Ann Thorac Surg 58 1994 806 810
    • (1994) Ann Thorac Surg , vol.58 , pp. 806-810
    • Yoshida, H.1    Yasuda, K.2    Tanabe, T.3
  • 14
    • 0028435032 scopus 로고
    • Treatment of acute aortic dissections with expandable metallic stents: Experimental study
    • N. Kato, T. Hirano, K. Takeda, T. Nakagawa, T. Mizumoto, H. Yuasa Treatment of acute aortic dissections with expandable metallic stents: experimental study J Vasc Interv Radiol 5 1994 417 423
    • (1994) J Vasc Interv Radiol , vol.5 , pp. 417-423
    • Kato, N.1    Hirano, T.2    Takeda, K.3    Nakagawa, T.4    Mizumoto, T.5    Yuasa, H.6
  • 15
    • 0007870838 scopus 로고
    • Experimental production of dissecting aneurysms of the aorta
    • F.S. Blanton, W.H. Muller, W.D. Warren Experimental production of dissecting aneurysms of the aorta Surgery 45 1959 81 90
    • (1959) Surgery , vol.45 , pp. 81-90
    • Blanton, F.S.1    Muller, W.H.2    Warren, W.D.3
  • 18
    • 77951244556 scopus 로고    scopus 로고
    • Controllable and uncontrollable Stanford type B aortic dissection in canine models
    • J. Tang, Y. Wang, W. Hang, W. Fu, Z. Jing Controllable and uncontrollable Stanford type B aortic dissection in canine models Eur Surg Res 44 2010 179 184
    • (2010) Eur Surg Res , vol.44 , pp. 179-184
    • Tang, J.1    Wang, Y.2    Hang, W.3    Fu, W.4    Jing, Z.5
  • 19
    • 0013565448 scopus 로고
    • Aneurysm formation in vivo by the topical degradation of adventitial elastin
    • J.V. White Aneurysm formation in vivo by the topical degradation of adventitial elastin J Vasc Surg 20 1994 153 156
    • (1994) J Vasc Surg , vol.20 , pp. 153-156
    • White, J.V.1
  • 21
    • 0031820775 scopus 로고    scopus 로고
    • Percutaneous creation of acute type-B aortic dissection: An experimental model for endoluminal therapy
    • M.K. Razavi, E. Nishimura, S. Slonim, W. Zeigler, S. Kee, H.L. Witherall Percutaneous creation of acute type-B aortic dissection: an experimental model for endoluminal therapy J Vasc Interv Radiol 9 1998 626 632
    • (1998) J Vasc Interv Radiol , vol.9 , pp. 626-632
    • Razavi, M.K.1    Nishimura, E.2    Slonim, S.3    Zeigler, W.4    Kee, S.5    Witherall, H.L.6
  • 23
    • 33846166455 scopus 로고    scopus 로고
    • Predictors of surgical indications for acute type B aortic dissection based on enlargement of aortic diameter during the chronic phase
    • H. Kunishige, K. Myojin, Y. Ishibashi, K. Ishii, M. Kawasaki, J. Oka Predictors of surgical indications for acute type B aortic dissection based on enlargement of aortic diameter during the chronic phase Jpn J Thorac Cardiovasc Surg 54 2006 477 482
    • (2006) Jpn J Thorac Cardiovasc Surg , vol.54 , pp. 477-482
    • Kunishige, H.1    Myojin, K.2    Ishibashi, Y.3    Ishii, K.4    Kawasaki, M.5    Oka, J.6
  • 24
    • 65649084533 scopus 로고    scopus 로고
    • Aortic diameter, true lumen, and false lumen growth rates in chronic type B aortic dissection
    • K.J. Blount, K.D. Hagspiel Aortic diameter, true lumen, and false lumen growth rates in chronic type B aortic dissection AJR Am J Roentgenol 192 2009 222 229
    • (2009) AJR Am J Roentgenol , vol.192 , pp. 222-229
    • Blount, K.J.1    Hagspiel, K.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.