Optimization of outside air cooling in data centers

Author keywords

[No Author keywords available]

Indexed keywords

AIR COOLING; ANNUAL AVERAGE; DATA CENTERS; HOT AIR; IT EQUIPMENT; LOCAL DISTRIBUTIONS; NON-HOMOGENEOUS; OPERATION TIME; SEASONAL VARIATION; SUPPLY AIR TEMPERATURE;

EID: 84860349020     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1115/IPACK2011-52132     Document Type: Conference Paper
Times cited : (10)

References (14)
  • 1
    • 77955224734 scopus 로고    scopus 로고
    • Thermofluids provisioning of a high density high performance data center
    • Hewlett Packard Laboratories, September
    • M. H. Beitelmal and C. D. Patel, "Thermofluids Provisioning of a High Density High Performance Data Center," Technical Report No. HPL-2004-146(R.1), Hewlett Packard Laboratories, September 2004.
    • (2004) Technical Report No. HPL-2004-146(R.1)
    • Beitelmal, M.H.1    Patel, C.D.2
  • 2
    • 40449131236 scopus 로고    scopus 로고
    • Energy flow in the information technology stack: Coefficient of performance of the ensemble and its impact on the total cost of ownership
    • March
    • C. Patel, R. K. Sharma, C. E. Bash, and M. Beitelmal, "Energy Flow in the Information Technology Stack: Coefficient of Performance of the Ensemble and its Impact on the Total Cost of Ownership," Technical Report No. HPL-2006-55, Hewlett Packard Laboratories, March 2006.
    • (2006) Technical Report No. HPL-2006-55, Hewlett Packard Laboratories
    • Patel, C.1    Sharma, R.K.2    Bash, C.E.3    Beitelmal, M.4
  • 5
    • 77955200373 scopus 로고    scopus 로고
    • From chip to cooling tower data center modeling: Part I influence of server inlet temperature and temperature rise across cabinet
    • Las Vegas, NV
    • T. J. Breen, E. J. Walsh, J. Punch, A. J. Shah, and C.E. Bash, "From chip to cooling tower data center modeling: Part I Influence of server inlet temperature and temperature rise across cabinet," Proc. ITHERM, Las Vegas, NV, 2010.
    • (2010) Proc. ITHERM
    • Breen, T.J.1    Walsh, E.J.2    Punch, J.3    Shah, A.J.4    Bash, C.E.5
  • 8
    • 33845582801 scopus 로고    scopus 로고
    • Dynamic thermal management of air cooled data centers
    • San Diego, CA
    • C. E. Bash, C. D. Patel, and R. K. Sharma, "Dynamic Thermal Management of Air Cooled Data Centers," Proc. ITHERM, San Diego, CA, 2006.
    • (2006) Proc. ITHERM
    • Bash, C.E.1    Patel, C.D.2    Sharma, R.K.3
  • 9
    • 70450082834 scopus 로고    scopus 로고
    • Reducing data center cost with an air economizer
    • D. Atwood and J. G. Miner, "Reducing Data Center Cost with an Air Economizer," Intel Brief, 2008.
    • (2008) Intel Brief
    • Atwood, D.1    Miner, J.G.2
  • 11
    • 70449597566 scopus 로고    scopus 로고
    • Use of airside economizer for data center thermal management
    • TheTA 2, Cairo, Egypt
    • A. Kumar and Y. Joshi, "Use of Airside Economizer for Data Center Thermal Management," Thermal Issues in Emerging Technologies, TheTA 2, Cairo, Egypt, 2008.
    • (2008) Thermal Issues in Emerging Technologies
    • Kumar, A.1    Joshi, Y.2
  • 13
    • 84950136782 scopus 로고    scopus 로고
    • Thermal consideration in cooling large scale high compute density data centers
    • San Diego, CA
    • C. Patel, R. K. Sharma, C. E. Bash, and M. Beitelmal, "Thermal Consideration in Cooling Large Scale High Compute Density Data Centers," Proceedings of ITHERM, San Diego, CA, 2002.
    • (2002) Proceedings of ITHERM
    • Patel, C.1    Sharma, R.K.2    Bash, C.E.3    Beitelmal, M.4
  • 14
    • 84885328382 scopus 로고    scopus 로고
    • Data obtained from the website of on Aug 20, 2010
    • Data obtained from the website of www.wunderground.com on Aug 20, 2010.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.