메뉴 건너뛰기




Volumn 198, Issue 5, 2012, Pages 1139-1143

Effect of beam-flow angle on velocity measurements in modern doppler ultrasound systems

Author keywords

Angle correction; Blood flow velocity; Doppler; Ultrasound

Indexed keywords

ARTICLE; COMPARATIVE EFFECTIVENESS; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DOPPLER FLOWMETRY; FLOW MEASUREMENT; FLOW RATE; IMAGING SYSTEM; MACHINE; PHANTOM; PRIORITY JOURNAL; RADIATION BEAM; REFERENCE VALUE; WATER FLOW;

EID: 84860327224     PISSN: 0361803X     EISSN: 15463141     Source Type: Journal    
DOI: 10.2214/AJR.11.7475     Document Type: Article
Times cited : (46)

References (12)
  • 1
    • 31144456928 scopus 로고    scopus 로고
    • Optimal peak systolic velocity threshold at duplex US for determining the need for carotid endarterectomy: A decision analytic approach
    • DOI 10.1148/radiol.2381041078
    • Heijenbrok-Kal MH, Buskens E, Nederkoorn PJ, van der Graaf Y, Hunink MG. Optimal peak systolic velocity threshold at duplex us for determining the need for carotid endarterectomy: a decision analytic approach. Radiology 2006; 238:480-488 (Pubitemid 43134360)
    • (2006) Radiology , vol.238 , Issue.2 , pp. 480-488
    • Heijenbrok-Kal, M.H.1    Buskens, E.2    Nederkoorn, P.J.3    Van Der, G.Y.4    Hunink, M.G.M.5
  • 2
    • 33847189214 scopus 로고    scopus 로고
    • Comparative accuracy of renal duplex sonographic parameters in the diagnosis of renal artery stenosis: Paired and unpaired analysis
    • Williams GJ, Macaskill P, Chan SF, et al. Comparative accuracy of renal duplex sonographic parameters in the diagnosis of renal artery stenosis: paired and unpaired analysis. AJR 2007; 188:798-811
    • (2007) AJR , vol.188 , pp. 798-811
    • Williams, G.J.1    Macaskill, P.2    Chan, S.F.3
  • 4
    • 45449099488 scopus 로고    scopus 로고
    • Correlation of Portal Venous Velocity and Portal Venous Flow With Short-Term Graft Regeneration in Recipients of Living Donor Liver Transplants
    • DOI 10.1016/j.transproceed.2008.01.074, PII S0041134508004429
    • Park MY, Lee YJ, Rha SE, Oh SN, Byun JY, Kim DG. Correlation of portal venous velocity and portal venous flow with short-term graft regeneration in recipients of living donor liver transplants. Transplant Proc 2008; 40:1488-1491 (Pubitemid 351853208)
    • (2008) Transplantation Proceedings , vol.40 , Issue.5 , pp. 1488-1491
    • Park, M.Y.1    Lee, Y.J.2    Rha, S.E.3    Oh, S.N.4    Byun, J.Y.5    Kim, D.G.6
  • 5
    • 0030065280 scopus 로고    scopus 로고
    • Accuracy of maximum velocity estimates made using Doppler ultrasound systems
    • Hoskins PR. Accuracy of maximum velocity estimates made using Doppler ultrasound systems. Br J Radiol 1996; 69:172-177 (Pubitemid 26067461)
    • (1996) British Journal of Radiology , vol.69 , Issue.818 , pp. 172-177
    • Hoskins, P.R.1
  • 6
    • 0034778642 scopus 로고    scopus 로고
    • Importance of angle correction in the measurement of blood flow velocity with transcranial doppler sonography
    • Krejza J, Mariak Z, Babikian VL. Importance of angle correction in the measurement of blood flow velocity with transcranial Doppler sonography. AJNR 2001; 22:1743-1747 (Pubitemid 32999586)
    • (2001) American Journal of Neuroradiology , vol.22 , Issue.9 , pp. 1743-1747
    • Krejza, J.1    Mariak, Z.2    Babikian, V.L.3
  • 11
    • 0042641667 scopus 로고    scopus 로고
    • Directional velocity estimation using focusing along the flow direction. Part II. Experimental investigation
    • Jensen JA, Bjerngaard R. Directional velocity estimation using focusing along the flow direction. Part II. Experimental investigation. IEEE Trans Ultrason Ferroelectr Freq Control 2003; 50:873-880
    • (2003) IEEE Trans Ultrason Ferroelectr Freq Control , vol.50 , pp. 873-880
    • Jensen, J.A.1    Bjerngaard, R.2
  • 12
    • 0029157780 scopus 로고
    • Correction of intrinsic spectral broadening errors in Doppler peak velocity measurements made with phased sector and linear array transducers
    • Winkler AJ, Wu J. Correction of intrinsic spectral broadening errors in Doppler peak velocity measurements made with phased sector and linear array transducers. Ultrasound Med Biol 1995; 21:1029-1035
    • (1995) Ultrasound Med Biol , vol.21 , pp. 1029-1035
    • Winkler, A.J.1    Wu, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.