메뉴 건너뛰기




Volumn 100, Issue 17, 2012, Pages

A permendur-piezoelectric multiferroic composite for low-noise ultrasensitive magnetic field sensors

Author keywords

[No Author keywords available]

Indexed keywords

BEST VALUE; ELECTROMECHANICAL RESONANCES; FIBER SENSOR; HIGH PERMEABILITY; LEAD ZIRCONATE TITANATE; LOW FREQUENCY; LOW NOISE; MAGNETIC FIELD CONFINEMENT; MAGNETIC FIELD SENSORS; MAGNETIC NOISE; ME COEFFICIENT; ME VOLTAGE COEFFICIENTS; MULTIFERROIC COMPOSITES; PERMENDUR; PZT FIBERS; TRILAYERS; ULTRASENSITIVE;

EID: 84860324489     PISSN: 00036951     EISSN: None     Source Type: Journal    
DOI: 10.1063/1.4705305     Document Type: Article
Times cited : (46)

References (27)
  • 1
    • 33747623307 scopus 로고    scopus 로고
    • Multiferroic and magnetoelectric materials
    • DOI 10.1038/nature05023, PII NATURE05023
    • W. Eerenstein, N. D. Mathur, and J. F. Scott, Nature 442, 759 (2006). 10.1038/nature05023 (Pubitemid 44261898)
    • (2006) Nature , vol.442 , Issue.7104 , pp. 759-765
    • Eerenstein, W.1    Mathur, N.D.2    Scott, J.F.3
  • 3
    • 77956987295 scopus 로고    scopus 로고
    • 10.1146/annurev-matsci-070909-104459
    • G. Srinivasan, Ann. Rev. Mater. Res. 40, 153 (2010). 10.1146/annurev- matsci-070909-104459
    • (2010) Ann. Rev. Mater. Res. , vol.40 , pp. 153
    • Srinivasan, G.1
  • 4
    • 79952140705 scopus 로고    scopus 로고
    • 10.1002/adma.201003636
    • J. Ma, J. Hu, Z. Li, and C. W. Nan, Adv. Mater. 23, 1062-1087 (2011). 10.1002/adma.201003636
    • (2011) Adv. Mater. , vol.23 , pp. 1062-1087
    • Ma, J.1    Hu, J.2    Li, Z.3    Nan, C.W.4
  • 6
    • 79958203721 scopus 로고    scopus 로고
    • Magnetoelectric coupling in Terfenol-D/polyvinylidenedifluoride composites
    • DOI 10.1063/1.1491006
    • K. Mori and M. Wuttig, Appl. Phys. Lett. 81, 100 (2002). 10.1063/1.1491006 (Pubitemid 34783715)
    • (2002) Applied Physics Letters , vol.81 , Issue.1 , pp. 100
    • Mori, K.1    Wuttig, M.2
  • 13
    • 34548691595 scopus 로고    scopus 로고
    • A new magnetic recording read head technology based on the magneto-electric effect
    • DOI 10.1088/0022-3727/40/17/003, PII S0022372707473090, 003
    • M. Vopsaroiu, J. Blackburn, and M. G. Cain, J. Phys. D: Appl. Phys. 40, 5027 (2007). 10.1088/0022-3727/40/17/003 (Pubitemid 47411295)
    • (2007) Journal of Physics D: Applied Physics , vol.40 , Issue.17 , pp. 5027-5033
    • Vopsaroiu, M.1    Blackburn, J.2    Cain, M.G.3
  • 14
    • 33846052967 scopus 로고    scopus 로고
    • Magnetic sensors and their applications
    • DOI 10.1109/JSEN.2006.874493
    • J. Lenz and A. S. Edelstein, IEEE Sensors 6, 631 (2006). 10.1109/JSEN.2006.874493 (Pubitemid 46405048)
    • (2006) IEEE Sensors Journal , vol.6 , Issue.3 , pp. 631-649
    • Lenz, J.1    Edelstein, A.S.2
  • 20
    • 84860339666 scopus 로고    scopus 로고
    • Tech. Bulletin ref:2605SA106192009 (Metglas Inc., Conway, SC), 2009
    • Tech. Bulletin ref:2605SA106192009 (Metglas Inc., Conway, SC), 2009.
  • 25
    • 84860324427 scopus 로고    scopus 로고
    • NAVY-II: APC 850 (APC International, Mackyville, PA)
    • Sample used: NAVY-II: APC 850, Physical and Piezoelectric Properties (APC International, Mackyville, PA), 2009.
    • (2009) Physical and Piezoelectric Properties
  • 27
    • 79955379531 scopus 로고    scopus 로고
    • 10.1063/1.3569629
    • J. Gao, L. Shen, J. Appl. Phys. 109, 074507 (2011). 10.1063/1.3569629
    • (2011) J. Appl. Phys. , vol.109 , pp. 074507
    • Gao, J.1    Shen, L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.