메뉴 건너뛰기




Volumn 44, Issue 8, 2012, Pages 757-765

Computational modeling of effects of intravascular stent design on key mechanical and hemodynamic behavior

Author keywords

Balloon expandable stent; Computational fluid dynamics; Finite element analysis; Parametric stent design; Stent fatigue life; Vascular disease

Indexed keywords

BALLOON-EXPANDABLE STENT; BLOOD FLOW; COMPUTATIONAL FLUID DYNAMICS MODELS; COMPUTATIONAL MODELING; COMPUTATIONAL SCHEMES; DOMINANT DESIGN; FINITE ELEMENT MODELS; FUNCTIONAL ATTRIBUTE; HUMAN BODIES; INNER WALLS; INTRAVASCULAR STENTS; MECHANICAL INTEGRITY; MEDICAL DEVICES; PARAMETRIC ANALYSIS; PARAMETRIC DESIGN; RADIAL STRENGTH; SENSITIVITY STUDIES; STENOTIC ARTERIES; STENT DESIGN; VASCULAR DISEASE; WALL SHEAR STRESS;

EID: 84860316478     PISSN: 00104485     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.cad.2012.03.009     Document Type: Article
Times cited : (74)

References (30)
  • 1
    • 0023153178 scopus 로고
    • Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty
    • U. Sigwart, J. Puel, and V. Mirkovitch Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty N Engl J Med 316 1987 701 706 (Pubitemid 17036474)
    • (1987) New England Journal of Medicine , vol.316 , Issue.12 , pp. 701-706
    • Sigwart, U.1    Puel, J.2    Mirkovitch, V.3
  • 4
    • 0038820113 scopus 로고    scopus 로고
    • Drug-eluting stents: Costs versus clinical benefit
    • DOI 10.1161/01.CIR.0000079018.84618.0E
    • W.W. O'Neill, and M.B. Leon Drug-eluting stents: cost versus clinical benefit Circulation 107 2003 3008 3011 (Pubitemid 36758970)
    • (2003) Circulation , vol.107 , Issue.24 , pp. 3008-3011
    • O'Neill, W.W.1    Leon, M.B.2
  • 5
    • 0038711003 scopus 로고    scopus 로고
    • New frontiers in cardiology: Drug-eluting stents: Part I
    • DOI 10.1161/01.CIR.0000069330.41022.90
    • J.E. Sousa, P.W. Serruys, and M.A. Costa New frontiers in cardiology: drug-eluting stents: part I Circulation 107 2003 2274 2279 (Pubitemid 36547225)
    • (2003) Circulation , vol.107 , Issue.17 , pp. 2274-2279
    • Sousa, J.E.1    Serruys, P.W.2    Costa, M.A.3
  • 6
    • 61849110613 scopus 로고    scopus 로고
    • A bioabsorbable everolimus-eluting coronary stent system (ABSORB)-2-year outcomes and results from multiple imaging methods
    • P.W. Serruys, J.A. Ormiston, and Y. Onuma A bioabsorbable everolimus-eluting coronary stent system (ABSORB)-2-year outcomes and results from multiple imaging methods Lancet 373 2009 897 910
    • (2009) Lancet , vol.373 , pp. 897-910
    • Serruys, P.W.1    Ormiston, J.A.2    Onuma, Y.3
  • 7
  • 8
    • 84858780075 scopus 로고    scopus 로고
    • Why similar stent designs cause new clinical issues?
    • H.M. Hsiao Why similar stent designs cause new clinical issues? J Am Coll Cardiol Intv 5 2012 362 363
    • (2012) J Am Coll Cardiol Intv , vol.5 , pp. 362-363
    • Hsiao, H.M.1
  • 9
    • 0034333737 scopus 로고    scopus 로고
    • Mechanical behaviour modelling of balloon-expandable stents
    • DOI 10.1016/S0021-9290(00)00098-1, PII S0021929000000981
    • C. Dumoulin, and B. Cochelin Mechanical behavior modeling of balloon-expandable stents J Biomech 33 2000 1461 1470 (Pubitemid 30625104)
    • (2000) Journal of Biomechanics , vol.33 , Issue.11 , pp. 1461-1470
    • Dumoulin, C.1    Cochelin, B.2
  • 10
    • 0034930155 scopus 로고    scopus 로고
    • Mechanical properties of coronary stents determined by using finite element analysis
    • DOI 10.1016/S0021-9290(01)00026-4, PII S0021929001000264
    • F. Etave, G. Finet, and M. Boivin Mechanical properties of coronary stents determined by using finite element analysis J Biomech 34 2001 1065 1075 (Pubitemid 32633776)
    • (2001) Journal of Biomechanics , vol.34 , Issue.8 , pp. 1065-1075
    • Etave, F.1    Finet, G.2    Boivin, M.3    Boyer, J.-C.4    Rioufol, G.5    Thollet, G.6
  • 11
    • 47949113474 scopus 로고    scopus 로고
    • Finite element comparison of performance related characteristics of balloon expandable stents
    • E.W. Donnelly, M.S. Bruzzi, and T. Connolley Finite element comparison of performance related characteristics of balloon expandable stents Comput Meth Biomech Biomed Eng 10 2007 103 110
    • (2007) Comput Meth Biomech Biomed Eng , vol.10 , pp. 103-110
    • Donnelly, E.W.1    Bruzzi, M.S.2    Connolley, T.3
  • 12
    • 41549127424 scopus 로고    scopus 로고
    • On the effects of different strategies in modeling balloon-expandable stenting by means of finite element method
    • F. Gervaso, C. Capello, and L. Petrini On the effects of different strategies in modeling balloon-expandable stenting by means of finite element method J Biomech 41 2008 1206 1212
    • (2008) J Biomech , vol.41 , pp. 1206-1212
    • Gervaso, F.1    Capello, C.2    Petrini, L.3
  • 13
    • 77955276585 scopus 로고    scopus 로고
    • Simulation of a balloon expandable stent in a realistic coronary artery - Determination of the optimum modeling strategy
    • H. Zahedmanesh, D.J. Kelly, and C. Lally Simulation of a balloon expandable stent in a realistic coronary artery - determination of the optimum modeling strategy J Biomech 43 2010 2126 2132
    • (2010) J Biomech , vol.43 , pp. 2126-2132
    • Zahedmanesh, H.1    Kelly, D.J.2    Lally, C.3
  • 14
    • 7544232441 scopus 로고    scopus 로고
    • Analysis of the mechanical performance of a cardiovascular stent design based on micromechanical modeling
    • J.P. McGarry, B.P. O'Donnell, and P.E. McHugh Analysis of the mechanical performance of a cardiovascular stent design based on micromechanical modeling Int J Comput Mater Sci Surf Eng 31 2004 421 438
    • (2004) Int J Comput Mater Sci Surf Eng , vol.31 , pp. 421-438
    • McGarry, J.P.1    O'Donnell, B.P.2    McHugh, P.E.3
  • 15
    • 28844502833 scopus 로고    scopus 로고
    • Fatigue and life prediction for cobalt-chromium stents: A fracture mechanics analysis
    • DOI 10.1016/j.biomaterials.2005.10.012, PII S0142961205009233
    • R.V. Marrey, R. Burgermeister, and R.B. Grishaber Fatigue and life prediction for cobalt-chromium stents: a fracture mechanics analysis Biomaterials 27 2006 1988 2000 (Pubitemid 41760438)
    • (2006) Biomaterials , vol.27 , Issue.9 , pp. 1988-2000
    • Marrey, R.V.1    Burgermeister, R.2    Grishaber, R.B.3    Ritchie, R.O.4
  • 16
    • 0036000226 scopus 로고    scopus 로고
    • Mechanical behavior of coronary stents investigated through the finite element method
    • DOI 10.1016/S0021-9290(02)00033-7, PII S0021929002000337
    • F. Migliavacca, L. Petrini, and M. Colombo Mechanical behavior of coronary stents investigated through the finite element method J Biomech 35 2002 803 811 (Pubitemid 34518378)
    • (2002) Journal of Biomechanics , vol.35 , Issue.6 , pp. 803-811
    • Migliavacca, F.1    Petrini, L.2    Colombo, M.3    Auricchio, F.4    Pietrabissa, R.5
  • 17
    • 16344362656 scopus 로고    scopus 로고
    • Changes in the mechanical environment of stenotic arteries during interaction with stents: Computational assessment of parametric stent designs
    • DOI 10.1115/1.1835362
    • G.A. Holzapfel, M. Stadler, and T.C. Gasser Changes in the mechanical environment of stenotic arteries during interaction with stents: computational assessment of parametric stent designs J Biomech Eng 127 2005 166 180 (Pubitemid 40467606)
    • (2005) Journal of Biomechanical Engineering , vol.127 , Issue.1 , pp. 166-180
    • Holzapfel, G.A.1    Stadler, M.2    Gasser, T.C.3
  • 18
    • 62949118408 scopus 로고    scopus 로고
    • Shape optimization of coronary artery stent based on a parametric model
    • N. Li, H. Zhang, and H. Ouyang Shape optimization of coronary artery stent based on a parametric model Finite Elem Anal Des 45 2009 468 475
    • (2009) Finite Elem Anal des , vol.45 , pp. 468-475
    • Li, N.1    Zhang, H.2    Ouyang, H.3
  • 19
    • 71649110168 scopus 로고    scopus 로고
    • Respiration-induced kidney motion on cobalt-chromium stent fatigue resistance
    • H.M. Hsiao, A. Nikanorov, and S. Prabhu Respiration-induced kidney motion on cobalt-chromium stent fatigue resistance J Biomed Mater Res B 91 2009 508 516
    • (2009) J Biomed Mater Res B , vol.91 , pp. 508-516
    • Hsiao, H.M.1    Nikanorov, A.2    Prabhu, S.3
  • 20
    • 84861202221 scopus 로고    scopus 로고
    • Life assessment of a balloon-expandable stent for atherosclerotic renal artery stenosis
    • A.N. Laskovski, InTech Croatia
    • H.M. Hsiao, M.D. Dake, and S. Prabhu Life assessment of a balloon-expandable stent for atherosclerotic renal artery stenosis A.N. Laskovski, Biomed. eng., trends in mater. sci 2011 InTech Croatia 447 464
    • (2011) Biomed. Eng., Trends in Mater. Sci , pp. 447-464
    • Hsiao, H.M.1    Dake, M.D.2    Prabhu, S.3
  • 21
    • 79954435990 scopus 로고    scopus 로고
    • A rapid and computationally inexpensive method to virtually implant current and next-generation stents into subject-specific computational fluid dynamics models
    • T.J. Gundert, S.C. Shadden, and A.R. Williams A rapid and computationally inexpensive method to virtually implant current and next-generation stents into subject-specific computational fluid dynamics models Ann Biomed Eng 39 2011 1423 1437
    • (2011) Ann Biomed Eng , vol.39 , pp. 1423-1437
    • Gundert, T.J.1    Shadden, S.C.2    Williams, A.R.3
  • 22
  • 24
    • 0004274342 scopus 로고
    • Cambridge University Press Cambridge (UK)
    • S. Suresh Fatigue of materials 1991 Cambridge University Press Cambridge (UK)
    • (1991) Fatigue of Materials
    • Suresh, S.1
  • 25
    • 0013873058 scopus 로고
    • Effects of hematocrit and plasma proteins on human blood rheology at low shear rates
    • S. Chien, S. Usami, and H.M. Taylor Effects of hematocrit and plasma proteins on human blood rheology at low shear rates J Appl Physiol 21 1966 81 87
    • (1966) J Appl Physiol , vol.21 , pp. 81-87
    • Chien, S.1    Usami, S.2    Taylor, H.M.3
  • 26
    • 18244381253 scopus 로고    scopus 로고
    • Computational study of fluid mechanical disturbance induced by endovascular stents
    • DOI 10.1007/s10439-005-2499-y
    • T. Seo, L.G. Schachter, and A.I. Barakat Computational study of fluid mechanical disturbance induced by endovascular stents Ann Biomed Eng 33 2005 444 456 (Pubitemid 40626483)
    • (2005) Annals of Biomedical Engineering , vol.33 , Issue.4 , pp. 444-456
    • Seo, T.1    Schachter, L.G.2    Barakat, A.I.3
  • 27
    • 18044371469 scopus 로고    scopus 로고
    • Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries
    • J.F. LaDisa Jr., L.E. Olson, and R.C. Molthen Alterations in wall shear stress predict sites of neointimal hyperplasia after stent implantation in rabbit iliac arteries Am J Physiol Heart Circ Physiol 288 2005 H2465 H2475
    • (2005) Am J Physiol Heart Circ Physiol , vol.288
    • Ladisa, Jr.J.F.1    Olson, L.E.2    Molthen, R.C.3
  • 29
    • 0642311549 scopus 로고    scopus 로고
    • Blood flow in arteries
    • D.N. Ku Blood flow in arteries Annu Rev Fluid Mech 29 1997 399 434
    • (1997) Annu Rev Fluid Mech , vol.29 , pp. 399-434
    • Ku, D.N.1
  • 30
    • 0021966255 scopus 로고
    • Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress
    • D.N. Ku, D.P. Giddens, and C.K. Zarins Pulsatile flow and atherosclerosis in the human carotid bifurcation. Positive correlation between plaque location and low oscillating shear stress Atherosclerosis 5 1985 292 302
    • (1985) Atherosclerosis , vol.5 , pp. 292-302
    • Ku, D.N.1    Giddens, D.P.2    Zarins, C.K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.