Error analysis of the X-ray projection geometry of camera-augmented mobile C-arm

Author keywords

[No Author keywords available]

Indexed keywords

CALIBRATION PROCEDURE; CALIBRATION TECHNIQUES; CROSS-RATIOS; DISTORTION CORRECTION; OPTICAL CAMERA; ORTHOPEDIC SURGERY; POSE ESTIMATION; RELATIVE POSE; RMS ERRORS; SYNTHETIC MODELS; VIDEO IMAGE; X-RAY PROJECTIONS;

EID: 84860236445     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.911324     Document Type: Conference Paper
Times cited : (6)

References (14)
  • 1
    • 0002042951 scopus 로고    scopus 로고
    • Camera-Augmented Mobile C-arm (CamC) Application: 3D Reconstruction Using a Low-Cost Mobile C-arm
    • N. Navab, M. Mitschke and O. Schütz. "Camera-Augmented Mobile C-arm (CamC) Application: 3D Reconstruction Using a Low-Cost Mobile C-arm.", MICCAI, 1999
    • (1999) MICCAI
    • Navab, N.1    Mitschke, M.2    Schütz, O.3
  • 4
    • 77954224040 scopus 로고    scopus 로고
    • Camera Augmented Mobile C-Arm (CamC): Calibration, Accuracy Study, and Clinical Applications
    • July
    • N.Navab, S.-M.Heining, J.Traub, "Camera Augmented Mobile C-Arm (CamC): Calibration, Accuracy Study, and Clinical Applications", Medical Imaging, IEEE Transactions on Medical Imaging, vol.29, no.7, pp.1412-1423, July 2010
    • (2010) Medical Imaging, IEEE Transactions on Medical Imaging , vol.29 , Issue.7 , pp. 1412-1423
    • Navab, N.1    Heining, S.-M.2    Traub, J.3
  • 5
    • 84860243008 scopus 로고    scopus 로고
    • Fluoroscopic Image Processing for Computer-Aided Orthopedic Surgery
    • Z.Yaniv, L.Joskowicz, A.Simkin, "Fluoroscopic Image Processing for Computer-Aided Orthopedic Surgery.", MICCAI, 1998.
    • (1998) MICCAI
    • Yaniv, Z.1    Joskowicz, L.2    Simkin, A.3
  • 7
    • 84860247554 scopus 로고    scopus 로고
    • Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of the image intensifier distortion
    • R.Fahrig, D-W.Holdsworth, "Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of the image intensifier distortion", Med. Phys., 2000
    • (2000) Med. Phys.
    • Fahrig, R.1    Holdsworth, D.-W.2
  • 10
    • 0023397578 scopus 로고
    • A Versatile Camera Calibration Technique for High-Accuracy 3D Machine Vision Metrology Using Off-the-Shelf TV Cameras and Lenses
    • R.Tsai, "A Versatile Camera Calibration Technique for High-Accuracy 3D Machine Vision Metrology Using Off-the-Shelf TV Cameras and Lenses", IEEE Journal of Robotics and Automation, 1987
    • (1987) IEEE Journal of Robotics and Automation
    • Tsai, R.1
  • 11
    • 0011973284 scopus 로고    scopus 로고
    • Robust Automatic C-arm Calibration for Fluoroscopy-based Navigation: A Practical Approach
    • H.Livyatan, Z.Yaniv, L.Joskowicz, "Robust Automatic C-arm Calibration for Fluoroscopy-based Navigation: a Practical Approach", MICCAI, 2002.
    • (2002) MICCAI
    • Livyatan, H.1    Yaniv, Z.2    Joskowicz, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.