메뉴 건너뛰기




Volumn 20, Issue 8, 2012, Pages 9090-9098

Simultaneous measurement of quality factor and wavelength shift by phase shift microcavity ring down spectroscopy

Author keywords

[No Author keywords available]

Indexed keywords

BAND STRUCTURE; BIOSENSORS; MICROCAVITIES; PHASE SHIFT; PHASE SHIFTERS; PROTEINS;

EID: 84860135778     PISSN: None     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OE.20.009090     Document Type: Article
Times cited : (54)

References (33)
  • 3
    • 78650487407 scopus 로고    scopus 로고
    • Photonics-on-a-chip: Recent advances in integrated waveguides as enabling detection elements for real-world, lab-on-a-chip biosensing applications
    • A. L. Washburn and R. C. Bailey, "Photonics-on-a-chip: recent advances in integrated waveguides as enabling detection elements for real-world, lab-on-a-chip biosensing applications," Analyst 136, 227 (2011).
    • (2011) Analyst , vol.136 , pp. 227
    • Washburn, A.L.1    Bailey, R.C.2
  • 4
    • 80052809438 scopus 로고    scopus 로고
    • Determination of binding kinetics using whispering gallery mode microcavities
    • C. E. Soteropulos, H. K. Hunt, and A. M. Armani, "Determination of binding kinetics using whispering gallery mode microcavities," Appl. Phys. Lett. 99, 103703 (2011).
    • (2011) Appl. Phys. Lett. , vol.99 , pp. 103703
    • Soteropulos, C.E.1    Hunt, H.K.2    Armani, A.M.3
  • 5
    • 79953192150 scopus 로고    scopus 로고
    • Application of ring down measurement approach to micro-cavities for bio-sensing applications
    • M. I. Cheema and A. G. Kirk, "Application of ring down measurement approach to micro-cavities for bio-sensing applications," Proc. SPIE 7888, 788808 (2011)
    • (2011) Proc. SPIE , vol.7888 , pp. 788808
    • Cheema, M.I.1    Kirk, A.G.2
  • 6
    • 0036406594 scopus 로고    scopus 로고
    • High-Q whispering-gallery mode sensor in liquids
    • V. S. Ilchenko and L. Maleki, "High-Q whispering-gallery mode sensor in liquids," Proc. SPIE 4629, 72 (2002).
    • (2002) Proc. SPIE , vol.4629 , pp. 72
    • Ilchenko, V.S.1    Maleki, L.2
  • 7
    • 33745925002 scopus 로고    scopus 로고
    • Heavy water detection using ultra-high-Q microcavities
    • DOI 10.1364/OL.31.001896
    • A. M. Armani and K. J. Vahala, "Heavy water detection using ultra-high-q microcavities," Opt. Lett. 31, 1896-1898 (2006). (Pubitemid 44048939)
    • (2006) Optics Letters , vol.31 , Issue.12 , pp. 1896-1898
    • Armani, A.M.1    Vahala, K.J.2
  • 8
    • 38549085707 scopus 로고    scopus 로고
    • On the performance quantification of resonant refractive index sensors
    • DOI 10.1364/OE.16.001020
    • I. M. White and X. Fan, "On the performance quantification of resonant refractive index sensors," Opt. Express 16, 1020-1028 (2008). (Pubitemid 351162269)
    • (2008) Optics Express , vol.16 , Issue.2 , pp. 1020-1028
    • White, I.M.1    Fan, X.2
  • 9
    • 67649267671 scopus 로고    scopus 로고
    • Design guidelines for optical resonator biochemical sensors
    • J. Hu, X. Sun, A. Agarwal, and L. C. Kimerling, "Design guidelines for optical resonator biochemical sensors," J. Opt. Soc. Am. B 26, 1032-1041 (2009).
    • (2009) J. Opt. Soc. Am. B , vol.26 , pp. 1032-1041
    • Hu, J.1    Sun, X.2    Agarwal, A.3    Kimerling, L.C.4
  • 10
    • 0021406864 scopus 로고
    • Mirror reflectometer based on optical cavity decay time
    • D. Anderson, J. Frisch, and C. Masser, "Mirror reflectometer based on optical cavity decay time," Appl. Opt. 23, 1238-1245 (1984). (Pubitemid 14562703)
    • (1984) Applied Optics , vol.23 , Issue.8 , pp. 1238-1245
    • Anderson Dana, Z.1    Frisch Josef, C.2    Masser Carl, S.3
  • 11
    • 29144464162 scopus 로고
    • Cavity ring-down optical spectrometer for absorption-measurements using pulsed laser sources
    • A. Okeefe and D. Deacon, "Cavity ring-down optical spectrometer for absorption-measurements using pulsed laser sources," Rev. Sci. Instrum. 59, 2544-2551 (1988).
    • (1988) Rev. Sci. Instrum. , vol.59 , pp. 2544-2551
    • Okeefe, A.1    Deacon, D.2
  • 13
    • 84882867283 scopus 로고    scopus 로고
    • Optimal signal processing in cavity ring-down spectroscopy
    • Elsevier
    • K. K. Lehmann and H. Huang, "Optimal Signal Processing in Cavity Ring-Down Spectroscopy," Frontiers of Molecular Spectroscopy (Elsevier, 2009), pp. 623-658.
    • (2009) Frontiers of Molecular Spectroscopy , pp. 623-658
    • Lehmann, K.K.1    Huang, H.2
  • 14
    • 0018918450 scopus 로고
    • Sensitive measurement of photon lifetime and true reflectances in an optical cavity by a phase-shift method
    • J. M. Herbelin, J. A. McKay, M. A. Kwok, R. H. Ueunten, D. S. Urevig, D. J. Spencer, and D. J. Benard, "Sensitive measurement of photon lifetime and true reflectances in an optical cavity by a phase-shift method," Appl. Opt. 19, 144-147 (1980). (Pubitemid 10481840)
    • (1980) Applied Optics , vol.19 , Issue.1 , pp. 144-147
    • Herbelin, J.M.1    McKay, J.A.2    Kwok, M.A.3    Ueunten, R.H.4    Urevig, D.S.5    Spencer, D.J.6    Benard, D.J.7
  • 15
    • 0030575761 scopus 로고    scopus 로고
    • Phase shift cavity ring down absorption spectroscopy
    • DOI 10.1016/0009-2614(96)01048-2, PII S0009261496010482
    • R. Engeln, G. VonHelden, G. Berden, and G. Meijer, "Phase shift cavity ring down absorption spectroscopy," Chem. Phys. Lett. 262, 105-109 (1996). (Pubitemid 126163448)
    • (1996) Chemical Physics Letters , vol.262 , Issue.1-2 , pp. 105-109
    • Engeln, R.1    Von Helden, G.2    Berden, G.3    Meijer, G.4
  • 18
    • 10844228103 scopus 로고    scopus 로고
    • Single-cell detection by cavity ring-down spectroscopy
    • DOI 10.1063/1.1819520
    • P. Tarsa, A. Wist, P. Rabinowitz, and K. K.Lehmann, "Single-cell detection by cavity ring-down spectroscopy," Appl. Phys. Lett. 85, 4523-4525 (2004). (Pubitemid 40001565)
    • (2004) Applied Physics Letters , vol.85 , Issue.19 , pp. 4523-4525
    • Tarsa, P.B.1    Wist, A.D.2    Rabinowitz, P.3    Lehmann, K.K.4
  • 21
    • 84871066876 scopus 로고    scopus 로고
    • Bioconjugation strategies for microtoroidal optical resonators
    • H. K. Hunt, C. Soteropulos, and A. M. Armani, "Bioconjugation strategies for microtoroidal optical resonators," Sensors 10, 9317-9336 (2010).
    • (2010) Sensors , vol.10 , pp. 9317-9336
    • Hunt, H.K.1    Soteropulos, C.2    Armani, A.M.3
  • 25
    • 77954194994 scopus 로고    scopus 로고
    • Cavity optomechanics with whispering-gallery mode optical micro-resonators
    • Elsevier Inc.
    • A. Schliesser and T. J. Kippenberg, "Cavity Optomechanics with Whispering-Gallery Mode Optical Micro-Resonators," Advances in Atomic Molecular and Optical Physics (Elsevier Inc., 2010), Vol. 58, pp. 207-323.
    • (2010) Advances in Atomic Molecular and Optical Physics , vol.58 , pp. 207-323
    • Schliesser, A.1    Kippenberg, T.J.2
  • 26
    • 0001034528 scopus 로고    scopus 로고
    • Phase-matched excitation of whispering-gallery-mode resonances by a fiber taper
    • J. C. Knight, G. Cheung, F. Jacques, and T. A. Birks, "Phase-matched excitation of whispering-gallery-mode resonances by a fiber taper," Opt. Lett. 22, 1129-1131 (1997). (Pubitemid 127562051)
    • (1997) Optics Letters , vol.22 , Issue.15 , pp. 1129-1131
    • Knight, J.C.1    Cheung, G.2    Jacques, F.3    Birks, T.A.4
  • 27
    • 0001272417 scopus 로고
    • Thermal nonlinear effects in optical whispering gallery microresonators
    • V. S. Ilchenko and M. L. Gorodetskii, "Thermal nonlinear effects in optical whispering gallery microresonators," Laser Phys. 2, 1004-1009 (1992).
    • (1992) Laser Phys. , vol.2 , pp. 1004-1009
    • Ilchenko, V.S.1    Gorodetskii, M.L.2
  • 28
    • 0001638758 scopus 로고
    • Influence of biotin lipid surface density and accessibility on avidin binding to the tip of an optical fiber sensor
    • S. Zhao and W. M. Reichert, "Influence of biotin lipid surface density and accessibility on avidin binding to the tip of an optical fiber sensor," Langmuir 8, 2785-2791 (1992).
    • (1992) Langmuir , vol.8 , pp. 2785-2791
    • Zhao, S.1    Reichert, W.M.2
  • 29
    • 35148887550 scopus 로고    scopus 로고
    • Analysis of whispering-gallery microcavityenhanced chemical absorption sensors
    • DOI 10.1364/OE.15.012959
    • A. T. Rosenberger, "Analysis of whispering-gallery microcavity-enhanced chemical absorption sensors," Opt. Express 15, 12959-12964 (2007). (Pubitemid 47538406)
    • (2007) Optics Express , vol.15 , Issue.20 , pp. 12959-12964
    • Rosenberger, A.T.1
  • 31
    • 83755183980 scopus 로고    scopus 로고
    • Detection limits in whispering gallery biosensors with plasmonic enhancement
    • J. D. Swaim, J. Knittel, and W. P. Bowen, "Detection limits in whispering gallery biosensors with plasmonic enhancement," Appl. Phys. Lett. 99, 243109 (2011).
    • (2011) Appl. Phys. Lett. , vol.99 , pp. 243109
    • Swaim, J.D.1    Knittel, J.2    Bowen, W.P.3
  • 32
    • 0038676487 scopus 로고    scopus 로고
    • Cavity ring-down spectroscopy as a detector for liquid chromatography
    • DOI 10.1021/ac0340152
    • K. L. Snyder and R. N. Zare, "Cavity ring-down spectroscopy as a detector for liquid chromatography," Anal. Chem. 75, 3086-3091 (2003). (Pubitemid 36830437)
    • (2003) Analytical Chemistry , vol.75 , Issue.13 , pp. 3086-3091
    • Snyder, K.L.1    Zare, R.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.