메뉴 건너뛰기




Volumn 20, Issue 3, 2012, Pages 310-320

Test procedures for maximum power point tracking charge controllers characterization

Author keywords

characterization; charge controllers; MPPT; PV stand alone systems; quality control; test procedures

Indexed keywords

CHARGE CONTROLLERS; ELECTRICAL SUPPLY; HIGH RELIABILITY; INDOOR MEASUREMENT; INTERNATIONAL STANDARDS; MAXIMUM POWER POINT TRACKING; MAXIMUM POWER POINT TRACKING ALGORITHMS; MPPT; OFF-GRIDS; OUTPUT POWER; PHOTOVOLTAIC; POWER ADAPTATION; PV ARRAYS; PV STAND-ALONE SYSTEMS; QUALITY REQUIREMENTS; REPRESENTATIVE DAYS; RURAL ELECTRIFICATION; SATELLITE APPLICATIONS; STANDALONE SYSTEMS; STATIC AND DYNAMIC; TEST PROCEDURES; WEATHER CONDITIONS;

EID: 84860008249     PISSN: 10627995     EISSN: 1099159X     Source Type: Journal    
DOI: 10.1002/pip.1139     Document Type: Article
Times cited : (13)

References (14)
  • 2
    • 84859972673 scopus 로고    scopus 로고
    • Seeking the power peak. Market survey on charge controllers 2008
    • Brand B,. Seeking the power peak. Market survey on charge controllers 2008. PHOTON International 2008; 114-129.
    • (2008) PHOTON International , pp. 114-129
    • Brand, B.1
  • 4
    • 34548414498 scopus 로고    scopus 로고
    • On the testing, characterization, and evaluation of PV inverters and dynamic MPPT performance under real varying operating conditions
    • DOI 10.1002/pip.763
    • Sanchís P, et al., On the testing characterization, and evaluation of PV inverters and dynamic MPPT performance under real varying operating conditions. Progress in Photovoltaics: Research and Applications 2007; 15: 541-556. (Pubitemid 47359503)
    • (2007) Progress in Photovoltaics: Research and Applications , vol.15 , Issue.6 , pp. 541-556
    • Sanchis, P.1    Lopez, J.2    Ursua, A.3    Gubia, E.4    Marroyo, L.5
  • 6
    • 84859990476 scopus 로고
    • Analytical expressions for the determination of the MPP and the fill factor
    • Araújo GL, Sánchez E,. Analytical expressions for the determination of the MPP and the fill factor. Solar Cells 1982; 5: 337-386.
    • (1982) Solar Cells , vol.5 , pp. 337-386
    • Araújo, G.L.1    Sánchez, E.2
  • 7
    • 0142217298 scopus 로고    scopus 로고
    • Experimental Analysis of Battery Charge Regulation in Photovoltaic Systems
    • DOI 10.1002/pip.509
    • Díaz P, Egido MA,. Experimental analysis of battery charge regulation in photovoltaic systems. Progress in Photovoltaics: Research and Applications 2003; 11 (7): 481-493. (Pubitemid 37320345)
    • (2003) Progress in Photovoltaics: Research and Applications , vol.11 , Issue.7 , pp. 481-493
    • Diaz, P.1    Egido, M.A.2
  • 8
    • 32044467799 scopus 로고    scopus 로고
    • Investigating performance, reliability and safety parameters of photovoltaic module inverter: Test results and compliances with the standards
    • DOI 10.1016/j.renene.2005.06.014, PII S0960148105001746
    • Islam S, Woyte A, Belmans R, Heskes PJM, Rooij PM,. Investigating performance, reliability and safety parameters of photovoltaic module inverter: test results and compliances with the standards. Renewable Energy 2005; 31: 1157-1181. (Pubitemid 43199553)
    • (2006) Renewable Energy , vol.31 , Issue.8 , pp. 1157-1181
    • Islam, S.1    Woyte, A.2    Belmans, R.3    Heskes, P.J.M.4    Rooij, P.M.5
  • 9
    • 6444245140 scopus 로고    scopus 로고
    • Dynamic evaluation of maximum power point tracking operation with PV array simulator
    • DOI 10.1016/S0927-0248(02)00185-X, PII S092702480200185X
    • Matsukawa H, Koshiishi K, Koizumi H, Kurokawa K, Hamada M, Bo L,. Dynamic evaluation of maximum power point tracking operation with PV array simulator. Solar Energy Materials and Solar Cells 2003; 75: 537-546. (Pubitemid 35409990)
    • (2003) Solar Energy Materials and Solar Cells , vol.75 , Issue.3-4 , pp. 537-546
    • Matsukawa, H.1    Koshiishi, K.2    Koizumi, H.3    Kurokawa, K.4    Hamada, M.5    Bo, L.6
  • 10
    • 33646128958 scopus 로고    scopus 로고
    • A new method based on charge parameters to analyse the performance of stand-alone photovoltaic systems
    • Muñoz FJ, Almonacid G, Nofuentes G, Almonacid F,. A new method based on charge parameters to analyse the performance of stand-alone photovoltaic systems. Solar Energy Materials and Solar Cells 2005; 90: 1750-1763.
    • (2005) Solar Energy Materials and Solar Cells , vol.90 , pp. 1750-1763
    • Muñoz, F.J.1    Almonacid, G.2    Nofuentes, G.3    Almonacid, F.4
  • 13
    • 0031370150 scopus 로고    scopus 로고
    • Maximum power point tracking charge controllers for telecom applications-analysis and economics
    • Wills RH,. Maximum power point tracking charge controllers for telecom applications-analysis and economics. Proceedings of the IEEE Photovoltaic Specialists Conference, 1997; 1997: 1109-1112.
    • (1997) Proceedings of the IEEE Photovoltaic Specialists Conference , vol.1997 , pp. 1109-1112
    • Wills, R.H.1
  • 14
    • 33750053294 scopus 로고    scopus 로고
    • DC power supply used as photovoltaic simulator for testing MPPT algorithms
    • DOI 10.1016/j.renene.2006.02.010, PII S0960148106000644
    • Mukerjee AK, Dasgupta N,. DC power supply used as photovoltaic simulator for testing MPPT algorithms. Renewable Energy 2007; 32: 587-592. (Pubitemid 44584678)
    • (2007) Renewable Energy , vol.32 , Issue.4 , pp. 587-592
    • Mukerjee, A.K.1    Dasgupta, N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.