메뉴 건너뛰기




Volumn 38, Issue , 2011, Pages 713-716

Deriving respiration from the pulse photoplethysmographic signal

Author keywords

[No Author keywords available]

Indexed keywords

PHOTOPLETHYSMOGRAPHIC SIGNALS; PULSE AMPLITUDE; PULSE RATE VARIABILITY; PULSEWIDTHS; RESPIRATORY RATE; RESPIRATORY SIGNALS; THREE PARAMETERS; TILT-TABLE TEST;

EID: 84859957036     PISSN: 23258861     EISSN: 2325887X     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (30)

References (7)
  • 1
    • 0032828520 scopus 로고    scopus 로고
    • Pulse rate variability is not a surrogate for heart rate variability
    • Constant I, Laude D, Murat I, Elghozi JL. Pulse rate variability is not a surrogate for heart rate variability. Clinical Science 1999;97(4):391-397.
    • (1999) Clinical Science , vol.97 , Issue.4 , pp. 391-397
    • Constant, I.1    Laude, D.2    Murat, I.3    Elghozi, J.L.4
  • 2
    • 78149330175 scopus 로고    scopus 로고
    • Photoplethysmography pulse rate as a surrogate measurement of heart rate variability during non-stationary conditions
    • Gil E, Orini M, Bailón R, Vergara JM, Mainardi L, Laguna P. Photoplethysmography pulse rate as a surrogate measurement of heart rate variability during non-stationary conditions. Physiological Measurement 2010;31:1271-1290.
    • (2010) Physiological Measurement , vol.31 , pp. 1271-1290
    • Gil, E.1    Orini, M.2    Bailón, R.3    Vergara, J.M.4    Mainardi, L.5    Laguna, P.6
  • 3
    • 33846921613 scopus 로고    scopus 로고
    • Pulse transit time-derived respiratory parameters and their variability across sleep stages
    • Chua CP, Heneghan C. Pulse transit time-derived respiratory parameters and their variability across sleep stages. Engineering in Medicine and Biology Society 2005;27:6153-6156.
    • (2005) Engineering in Medicine and Biology Society , vol.27 , pp. 6153-6156
    • Chua, C.P.1    Heneghan, C.2
  • 4
    • 33746855128 scopus 로고    scopus 로고
    • A robust method for ecg-based estimation of the respiratory frequency during stress testing
    • Bailón R, Sörnmo L, Laguna P. A robust method for ecg-based estimation of the respiratory frequency during stress testing. IEEE transactions on biomedical engineering 2006;53(7):1273-1285.
    • (2006) IEEE Transactions on Biomedical Engineering , vol.53 , Issue.7 , pp. 1273-1285
    • Bailón, R.1    Sörnmo, L.2    Laguna, P.3
  • 5
    • 0030032972 scopus 로고    scopus 로고
    • A comparison of adaptative and nonadaptative filters for the reduction of powerline interference in the ecg
    • Hamilton PS. A comparison of adaptative and nonadaptative filters for the reduction of powerline interference in the ecg. IEEE Transactions on Biomedical Engineering 1996;43:105-109.
    • (1996) IEEE Transactions on Biomedical Engineering , vol.43 , pp. 105-109
    • Hamilton, P.S.1
  • 6
    • 52049090570 scopus 로고    scopus 로고
    • Detection of decreases in the amplitude fluctuation of pulse photoplethysmography signal as indication of obstructive sleep apnea syndrome in children
    • Gil E, Vergara JM, Laguna P. Detection of decreases in the amplitude fluctuation of pulse photoplethysmography signal as indication of obstructive sleep apnea syndrome in children. Biomedical Signal Porcessing and Control 2008;3:267-277.
    • (2008) Biomedical Signal Porcessing and Control , vol.3 , pp. 267-277
    • Gil, E.1    Vergara, J.M.2    Laguna, P.3
  • 7
    • 0028211695 scopus 로고
    • Automatic detection of wave boundaries in multilead ECG signals: Validation with the CSE database
    • Laguna P, Jané R, Caminal P. Automatic detection of wave boundaries in multilead ECG signals: validation with the CSE database. Computers and Biomedical Research 1994;27:45-60.
    • (1994) Computers and Biomedical Research , vol.27 , pp. 45-60
    • Laguna, P.1    Jané, R.2    Caminal, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.