메뉴 건너뛰기




Volumn 153, Issue 5, 2012, Pages 868-872

Retinal breaks in small-gauge pars plana vitrectomy

Author keywords

[No Author keywords available]

Indexed keywords

AGED; CASE STUDY; DIABETIC RETINOPATHY; EPIRETINAL MEMBRANE; FEMALE; FOLLOW UP; HUMAN; INTERVENTION STUDY; LENS; MAJOR CLINICAL STUDY; MALE; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; PROSPECTIVE STUDY; RETINA DETACHMENT; RETINA DISEASE; RETINA MACULA HOLE; RETINAL BREAK; RETINOPEXY; REVIEW; SCLEROTOMY; SURGICAL PATIENT; TREATMENT INDICATION; TREATMENT OUTCOME; VITRECTOMY; VITREOUS FLOATERS; VITREOUS HEMORRHAGE;

EID: 84859799184     PISSN: 00029394     EISSN: 18791891     Source Type: Journal    
DOI: 10.1016/j.ajo.2011.10.015     Document Type: Article
Times cited : (31)

References (20)
  • 2
    • 0033508537 scopus 로고    scopus 로고
    • Visual and surgical outcomes of retinal detachment following macular hole repair
    • J.S. Heier, T.M. Topping, A.R. Frederick Jr, M.G. Morley, R. Millay, R.D. Pesavento Visual and surgical outcomes of retinal detachment following macular hole repair Retina 19 2 1999 110 115 (Pubitemid 30368154)
    • (1999) Retina , vol.19 , Issue.2 , pp. 110-115
    • Heier, J.S.1    Topping, T.M.2    Frederick Jr., A.R.3    Morley, M.G.4    Millay, R.5    Pesavento, R.D.6
  • 4
    • 0020620707 scopus 로고
    • Complications of vitreous surgery for diabetic retinopathy. I. Intraoperative complications
    • R.T. Oyakawa, A.P. Schachat, R.G. Michels, T.A. Rice Complications of vitreous surgery for diabetic retinopathy I. Intraoperative complications Ophthalmology 90 5 1983 517 521 (Pubitemid 13059781)
    • (1983) Ophthalmology , vol.90 , Issue.5 , pp. 517-521
    • Oyakawa, R.T.1    Schachat, A.P.2    Michels, R.G.3    Rice, T.A.4
  • 5
    • 68949126725 scopus 로고    scopus 로고
    • Iatrogenic retinal breaks in 25-gauge macular surgery
    • H.S. Tan, M. Mura, M.D. de Smet Iatrogenic retinal breaks in 25-gauge macular surgery Am J Ophthalmol 148 3 2009 427 430
    • (2009) Am J Ophthalmol , vol.148 , Issue.3 , pp. 427-430
    • Tan, H.S.1    Mura, M.2    De Smet, M.D.3
  • 6
    • 0033512817 scopus 로고    scopus 로고
    • Retinal detachment associated with macular hole surgery: Characteristics, mechanism, and outcomes
    • H. Tabandeh, N.A. Chaudhry, W.E. Smiddy Retinal detachment associated with macular hole surgery: characteristics, mechanism, and outcomes Retina 19 4 1999 281 286 (Pubitemid 30368111)
    • (1999) Retina , vol.19 , Issue.4 , pp. 281-286
    • Tabandeh, H.1    Chaudhry, N.A.2    Smiddy, W.E.3
  • 7
    • 78149490881 scopus 로고    scopus 로고
    • Enhanced internal search for iatrogenic retinal breaks in 20-gauge macular surgery
    • H.S. Tan, S.Y. Lesnik Oberstein, M. Mura, M.D. de Smet Enhanced internal search for iatrogenic retinal breaks in 20-gauge macular surgery Br J Ophthalmol 94 11 2010 1490 1492
    • (2010) Br J Ophthalmol , vol.94 , Issue.11 , pp. 1490-1492
    • Tan, H.S.1    Lesnik Oberstein, S.Y.2    Mura, M.3    De Smet, M.D.4
  • 8
    • 0026341259 scopus 로고
    • The pars plana incision: Experimental studies, pathologic observations, and clinical experience
    • A.E. Krieger The pars plana incision: experimental studies, pathologic observations, and clinical experience Trans Am Ophthalmol Soc 89 1991 549 621
    • (1991) Trans Am Ophthalmol Soc , vol.89 , pp. 549-621
    • Krieger, A.E.1
  • 9
    • 33845508068 scopus 로고    scopus 로고
    • Intraoperative Sclerotomy-related Retinal Breaks for Macular Surgery, 20- vs 25-Gauge Vitrectomy Systems
    • DOI 10.1016/j.ajo.2006.07.038, PII S0002939406008786
    • R. Scartozzi, A.S. Bessa, O.P. Gupta, C.D. Regillo Intraoperative sclerotomy-related retinal breaks for macular surgery, 20- vs 25-gauge vitrectomy systems Am J Ophthalmol 143 1 2007 155 156 (Pubitemid 44917805)
    • (2007) American Journal of Ophthalmology , vol.143 , Issue.1 , pp. 155-156
    • Scartozzi, R.1    Bessa, A.S.2    Gupta, O.P.3    Regillo, C.D.4
  • 11
    • 54249142174 scopus 로고    scopus 로고
    • 25-, 23-, or 20-gauge instrumentation for vitreous surgery?
    • G.A. Williams 25-, 23-, or 20-gauge instrumentation for vitreous surgery? Eye (Lond) 22 10 2008 1263 1266
    • (2008) Eye (Lond) , vol.22 , Issue.10 , pp. 1263-1266
    • Williams, G.A.1
  • 12
    • 34447315858 scopus 로고    scopus 로고
    • 25-Gauge macular surgery: Results and complications
    • DOI 10.1097/IAE.0b013e31802c5125, PII 0000698220070700000013
    • F. Patelli, P. Radice, G. Zumbo, G. Frisone, G. Fasolino 25-gauge macular surgery: results and complications Retina 27 6 2007 750 754 (Pubitemid 47051771)
    • (2007) Retina , vol.27 , Issue.6 , pp. 750-754
    • Patelli, F.1    Radice, P.2    Zumbo, G.3    Frisone, G.4    Fasolino, G.5
  • 14
    • 77956344215 scopus 로고    scopus 로고
    • Risk of iatrogenic peripheral retinal breaks in 20-G pars plana vitrectomy
    • Y.D. Ramkissoon, S.A. Aslam, S.P. Shah, S.C. Wong, P.M. Sullivan Risk of iatrogenic peripheral retinal breaks in 20-G pars plana vitrectomy Ophthalmology 117 9 2010 1825 1830
    • (2010) Ophthalmology , vol.117 , Issue.9 , pp. 1825-1830
    • Ramkissoon, Y.D.1    Aslam, S.A.2    Shah, S.P.3    Wong, S.C.4    Sullivan, P.M.5
  • 15
    • 67349117791 scopus 로고    scopus 로고
    • Retinal breaks associated with the induction of posterior vitreous detachment
    • S.E. Chung, K.H. Kim, S.W. Kang Retinal breaks associated with the induction of posterior vitreous detachment Am J Ophthalmol 147 6 2009 1012 1016
    • (2009) Am J Ophthalmol , vol.147 , Issue.6 , pp. 1012-1016
    • Chung, S.E.1    Kim, K.H.2    Kang, S.W.3
  • 16
    • 0025330654 scopus 로고
    • Iatrogenic retinal breaks complicating pars plana vitrectomy
    • discussion 854
    • J.B. Carter, R.G. Michels, B.M. Glaser, S. De Bustros Iatrogenic retinal breaks complicating pars plana vitrectomy Ophthalmology 97 7 1990 848 853 discussion 854
    • (1990) Ophthalmology , vol.97 , Issue.7 , pp. 848-853
    • Carter, J.B.1    Michels, R.G.2    Glaser, B.M.3    De Bustros, S.4
  • 17
    • 79251544220 scopus 로고    scopus 로고
    • Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy
    • S.A. Issa, A. Connor, M. Habib, D.H. Steel Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy Clin Ophthalmol 5 2011 109 114
    • (2011) Clin Ophthalmol , vol.5 , pp. 109-114
    • Issa, S.A.1    Connor, A.2    Habib, M.3    Steel, D.H.4
  • 18
    • 67349285875 scopus 로고    scopus 로고
    • Microincision vitrectomy surgery and intravitreal bevacizumab as a surgical adjunct to treat diabetic traction retinal detachment
    • Y. Oshima, C. Shima, T. Wakabayashi Microincision vitrectomy surgery and intravitreal bevacizumab as a surgical adjunct to treat diabetic traction retinal detachment Ophthalmology 116 5 2009 927 938
    • (2009) Ophthalmology , vol.116 , Issue.5 , pp. 927-938
    • Oshima, Y.1    Shima, C.2    Wakabayashi, T.3
  • 19
    • 78650173491 scopus 로고    scopus 로고
    • Comparison of clinical outcomes between 23-gauge and 20-gauge vitrectomy in patients with proliferative diabetic retinopathy
    • D.H. Park, J.P. Shin, S.Y. Kim Comparison of clinical outcomes between 23-gauge and 20-gauge vitrectomy in patients with proliferative diabetic retinopathy Retina 30 10 2010 1662 1670
    • (2010) Retina , vol.30 , Issue.10 , pp. 1662-1670
    • Park, D.H.1    Shin, J.P.2    Kim, S.Y.3
  • 20
    • 35448967053 scopus 로고    scopus 로고
    • Entry-site-related retinal detachment after pars plana vitrectomy
    • DOI 10.1111/j.1600-0420.2007.00930.x
    • B. Wimpissinger, S. Binder Entry-site-related retinal detachment after pars plana vitrectomy Acta Ophthalmol Scand 85 7 2007 782 785 (Pubitemid 47616797)
    • (2007) Acta Ophthalmologica Scandinavica , vol.85 , Issue.7 , pp. 782-785
    • Wimpissinger, B.1    Binder, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.