메뉴 건너뛰기




Volumn 10, Issue 4, 2012, Pages 353-370

A review of CO2 measurement procedures in ventilation research

Author keywords

Carbon dioxide; Indoor air quality measurement strategy; Sampling heights; Sampling location

Indexed keywords

AIR QUALITY; ATMOSPHERIC COMPOSITION; BUILDINGS; IMPORTANCE SAMPLING; INDOOR AIR POLLUTION; LOCATION; SURVEYS; UNCERTAINTY ANALYSIS;

EID: 84859791880     PISSN: 14733315     EISSN: None     Source Type: Journal    
DOI: 10.1080/14733315.2012.11683961     Document Type: Article
Times cited : (82)

References (53)
  • 1
    • 0003427027 scopus 로고    scopus 로고
    • ASHRAE Atlanta, USA. American Society of Heating, Refrigeration and Air- Conditioning Engineers ANSI/ASHRAE 62.1, 2010
    • ASHRAE: (2010) "Ventilation for Acceptable Indoor Air Quality" Atlanta, USA. American Society of Heating, Refrigeration and Air- Conditioning Engineers ANSI/ASHRAE 62.1, 2010.
    • (2010) Ventilation for Acceptable Indoor Air Quality
  • 4
    • 0010213876 scopus 로고    scopus 로고
    • Dispersal of exhaled air and personal exposure in displacement ventilated rooms
    • Bjorn E and Nielsen PV: (2002). "Dispersal of exhaled air and personal exposure in displacement ventilated rooms". Indoor Air, 12, (3), pp147-164. (Pubitemid 135746000)
    • (2002) Indoor Air , vol.12 , Issue.3 , pp. 147-164
    • Bjorn, E.1    Nielsen, P.V.2
  • 5
    • 55549119252 scopus 로고    scopus 로고
    • Indoor air quality in new hotels' guest rooms of the major world factory region
    • Chan W et al: (2009). "Indoor air quality in new hotels' guest rooms of the major world factory region". International Journal of Hospitality Management, 28, pp26-32.
    • (2009) International Journal of Hospitality Management , vol.28 , pp. 26-32
    • Chan, W.1
  • 6
    • 52949104757 scopus 로고    scopus 로고
    • Survey of airborne bacterial genus at a university campus
    • Chan WT et al: (2008). "Survey of Airborne Bacterial Genus at a University Campus". Indoor and Built Environment, 17, pp460-466.
    • (2008) Indoor and Built Environment , vol.17 , pp. 460-466
    • Chan, W.T.1
  • 7
    • 0035254743 scopus 로고    scopus 로고
    • Development and application of an indoor air quality audit to an air-conditioned building in Singapore
    • DOI 10.1016/S0360-1323(99)00064-5
    • Cheong KW and Chong KY: (2001). "Development and application of an indoor air quality audit to an air-conditioned building in Singapore". Building and Environment, 36. pp181-188. (Pubitemid 32071497)
    • (2001) Building and Environment , vol.36 , Issue.2 , pp. 181-188
    • Cheong, K.W.1    Chong, K.Y.2
  • 8
    • 63649142627 scopus 로고    scopus 로고
    • Assessment of air changerates in chemical laboratories
    • Chien YC et al: (2009). "Assessment of air changerates in chemical laboratories". Indoor and Built Environment, 18, pp162-167.
    • (2009) Indoor and Built Environment , vol.18 , pp. 162-167
    • Chien, Y.C.1
  • 9
    • 33845592313 scopus 로고    scopus 로고
    • A study of the effect of heat source location in a ventilated room using multiple regression analysis
    • DOI 10.1016/j.buildenv.2006.03.008, PII S0360132306000771
    • Cho Y and Awbi HB: (2007). "A study of the effect of heat source location in a ventilated room using multiple regression analysis". Building and Environment, 42, (5), pp2072-2082. (Pubitemid 44933016)
    • (2007) Building and Environment , vol.42 , Issue.5 , pp. 2072-2082
    • Cho, Y.1    Awbi, H.B.2
  • 10
    • 0035501647 scopus 로고    scopus 로고
    • Effect of ventilation pattern on room air and contaminant distribution
    • DOI 10.1016/S0360-1323(00)00051-2, PII S0360132300000512
    • Chung K-C and Hsu S-P: (2001). "Effect of ventilation pattern on room air and contaminant distribution". Building and Environment, 36, (9), pp989-998. (Pubitemid 32926089)
    • (2001) Building and Environment , vol.36 , Issue.9 , pp. 989-998
    • Chung, K.-C.1    Hsu, S.-P.2
  • 11
    • 33748295748 scopus 로고    scopus 로고
    • Air quality inside a school building: Air exchange monitoring, evolution of carbon dioxide and assessment of ventilation strategies
    • Conceição EZE and. Lúcio MMJR: (2006). "Air quality inside a school building: air exchange monitoring, evolution of carbon dioxide and assessment of ventilation strategies". International Journal of Ventilation, 5, (2), pp259-270. (Pubitemid 44323581)
    • (2006) International Journal of Ventilation , vol.5 , Issue.2 , pp. 259-270
    • Conceicao, E.Z.E.1    Lucio, M.M.J.R.2
  • 12
    • 84859792410 scopus 로고    scopus 로고
    • Indoor air quality in classrooms: Filed campaign by questionnaires and measurements
    • Air Infiltration and Ventilation Centre
    • th AIVC conference, Prague, Air Infiltration and Ventilation Centre.
    • (2004) th AIVC Conference, Prague
    • Corgnati, S.1    Viazzo, S.2
  • 13
    • 0037365997 scopus 로고    scopus 로고
    • Indoor air quality, ventilation and health symptoms in schools: An analysis of existing information
    • DOI 10.1034/j.1600-0668.2003.00153.x
    • Daisey JM et al: (2003). "Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information". Indoor Air, 13, (1), pp53-64. (Pubitemid 37463589)
    • (2003) Indoor Air , vol.13 , Issue.1 , pp. 53-64
    • Daisey, J.M.1    Angell, W.J.2    Apte, M.G.3
  • 14
    • 14944356570 scopus 로고    scopus 로고
    • Elemental carbon and respirable particulate matter in the indoor air of apartments and nursery schools and ambient air in Berlin (Germany)
    • DOI 10.1111/j.1600-0668.2005.00377.x
    • Fromme H et al: (2005). "Elemental carbon and respirable matter in the indoor air of apartments and nursery schools and ambient air in Berlin (Germany)". Indoor Air, 15, pp335-341. (Pubitemid 41219468)
    • (2005) Indoor Air , vol.15 , Issue.5 , pp. 335-341
    • Fromme, H.1    Lahrz, T.2    Hainsch, A.3    Oddoy, A.4    Piloty, M.5    Ruden, H.6
  • 15
    • 33845776578 scopus 로고    scopus 로고
    • Particulate matter in the indoor air of classrooms-exploratory results from Munich and surrounding area
    • DOI 10.1016/j.atmosenv.2006.08.053, PII S1352231006009046
    • Fromme H et al: (2007). "Particulate matter in the indoor air of classrooms-exploratory results from Munich and surrounding area." Atmospheric Environment, 41, (4), pp854-866. (Pubitemid 46001761)
    • (2007) Atmospheric Environment , vol.41 , Issue.4 , pp. 854-866
    • Fromme, H.1    Twardella, D.2    Dietrich, S.3    Heitmann, D.4    Schierl, R.5    Liebl, B.6    Ruden, H.7
  • 16
    • 33947593526 scopus 로고    scopus 로고
    • Indoor air quality in Michigan schools
    • DOI 10.1111/j.1600-0668.2006.00459.x
    • Godwin C and Batterman S: (2007). "Indoor air quality in Michigan schools." Indoor Air, 17, (2), pp109-121. (Pubitemid 46481130)
    • (2007) Indoor Air , vol.17 , Issue.2 , pp. 109-121
    • Godwin, C.1    Batterman, S.2
  • 17
    • 38649124011 scopus 로고    scopus 로고
    • Impact of ventilation scenario on air exchange rates and on indoor particle number concentrations in an air-conditioned classroom
    • DOI 10.1016/j.atmosenv.2007.09.070, PII S1352231007008758
    • Guo H et al: (2008). "Impact of ventilation scenario on air exchange rates and on indoor particle number concentrations in an air-conditioned classroom". Atmospheric Environment, 42, (4), pp757-768. (Pubitemid 351172846)
    • (2008) Atmospheric Environment , vol.42 , Issue.4 , pp. 757-768
    • Guo, H.1    Morawska, L.2    He, C.3    Gilbert, D.4
  • 18
    • 36549070230 scopus 로고    scopus 로고
    • Carbon dioxide concentration and its application on estimating the air change rate in typical Irish houses
    • Guo L and Lewis JO: (2007). "Carbon Dioxide Concentration and its Application on Estimating the Air Change Rate in Typical Irish Houses". International Journal of Ventilation, 6, (3). pp235-245. (Pubitemid 350187128)
    • (2007) International Journal of Ventilation , vol.6 , Issue.3 , pp. 235-245
    • Guo, L.1    Lewis, J.O.2
  • 19
    • 20744446917 scopus 로고    scopus 로고
    • Particle deposition rates in residential houses
    • DOI 10.1016/j.atmosenv.2005.03.016, PII S1352231005002815
    • He C et al: (2005). "Particle deposition rates in residential houses." Atmospheric Environment, 39, pp3891-3899. (Pubitemid 40854283)
    • (2005) Atmospheric Environment , vol.39 , Issue.21 , pp. 3891-3899
    • He, C.1    Morawska, L.2    Gilbert, D.3
  • 21
    • 33746178471 scopus 로고    scopus 로고
    • Feasibility study of an express assessment protocol for the indoor air quality of air-conditioned offices
    • DOI 10.1177/1420326X06067866
    • Hui PS et al: (2006). "Feasibility study of an express assessment protocol for the indoor air quality of airconditioned offices." Indoor and Built Environment, 15, (4), pp373-378. (Pubitemid 44086706)
    • (2006) Indoor and Built Environment , vol.15 , Issue.4 , pp. 373-378
    • Hui, P.S.1    Wong, L.T.2    Mui, K.W.3
  • 23
    • 0036976518 scopus 로고    scopus 로고
    • Monitoring and modelling indoor air quality and ventilation in classrooms within a purpose-designed naturally ventilated school
    • DOI 10.1159/000068232
    • Kolokotroni M et al: (2002). "Monitoring and Modelling Indoor Air Quality and Ventilation in Classrooms within a Purpose-Designed Naturally Ventilated School". Indoor and Built Environment, 11, (6), pp316-326. (Pubitemid 36160306)
    • (2002) Indoor and Built Environment , vol.11 , Issue.6 , pp. 316-326
    • Kolokotroni, M.1    Ge, Y.T.2    Katsoulas, D.3
  • 24
    • 0034048419 scopus 로고    scopus 로고
    • Indoor and outdoor air quality investigation at schools in Hong Kong
    • DOI 10.1016/S0045-6535(99)00396-3, PII S0045653599003963
    • Lee SC and Chang M: (2000). "Indoor and outdoor air quality investigation at schools in Hong Kong." Chemosphere, 41, (1-2), pp109-113. (Pubitemid 30226551)
    • (2000) Chemosphere , vol.41 , Issue.1-2 , pp. 109-113
    • Lee, S.C.1    Chang, M.2
  • 25
    • 0035851270 scopus 로고    scopus 로고
    • Indoor air quality at restaurants with different styles of cooking in metropolitan Hong Kong
    • DOI 10.1016/S0048-9697(01)00765-3, PII S0048969701007653
    • Lee SC et al: (2001). "Indoor air quality at restaurants with different styles of cooking in metropolitan Hong Kong." The Science of The Total Environment, 279, pp181-193. (Pubitemid 33033145)
    • (2001) Science of the Total Environment , vol.279 , Issue.1-3 , pp. 181-193
    • Lee, S.C.1    Li, W.-M.2    Yin Chan, L.3
  • 26
    • 0346461410 scopus 로고    scopus 로고
    • Characteristics of emissions of air pollutants from burning of incense in a large environmental chamber
    • DOI 10.1016/j.atmosenv.2003.11.002
    • Lee SC and Wang B: (2004). "Characteristics of emissions of air pollutants from burning of incense in a large environmental chamber." Atmospheric Environment, 38, (7), pp941-951. (Pubitemid 38083226)
    • (2004) Atmospheric Environment , vol.38 , Issue.7 , pp. 941-951
    • Lee, S.-C.1    Wang, B.2
  • 29
    • 77952583675 scopus 로고    scopus 로고
    • The spatial distribution of carbon dioxide in an environmental test chamber
    • Mahyuddin N and Awbi H: (2010). "The spatial distribution of carbon dioxide in an environmental test chamber." Building and Environment, 45, (9), pp1993-2001.
    • (2010) Building and Environment , vol.45 , Issue.9 , pp. 1993-2001
    • Mahyuddin, N.1    Awbi, H.2
  • 30
    • 84942857309 scopus 로고    scopus 로고
    • Investigating carbon dioxide in high occupancy buildings with particular application to classrooms
    • ISBN: 9788778772701
    • Mahyuddin N et al: (2008). "Investigating Carbon Dioxide in High Occupancy Buildings with Particular Application to Classrooms." The 11th International Conference on Indoor Air Quality and Climate: ISBN: 9788778772701.
    • (2008) The 11th International Conference on Indoor Air Quality and Climate
    • Mahyuddin, N.1
  • 31
    • 0020941650 scopus 로고
    • A method to select locations for indoor air quality sampling
    • DOI 10.1016/0360-1323(83)90025-2
    • Maldonado EAB and Woods JE: (1983). "A method to select locations for indoor air quality sampling." Building and Environment, 18, (4), pp171-180. (Pubitemid 14508270)
    • (1983) Building and Environment , vol.18 , Issue.4 , pp. 171-180
    • Maldonado, E.A.B.1    Woods, J.E.2
  • 32
    • 71749088126 scopus 로고    scopus 로고
    • An assessment of indoor air quality in recent Mexican immigrant housing in Commerce City, Colorado
    • Miller SL et al: (2009). "An assessment of indoor air quality in recent Mexican immigrant housing in Commerce City, Colorado." Atmospheric Environment, 43, (35), pp5661-5667.
    • (2009) Atmospheric Environment , vol.43 , Issue.35 , pp. 5661-5667
    • Miller, S.L.1
  • 33
    • 33744946068 scopus 로고    scopus 로고
    • Evaluation on sampling point densities for assessing indoor air quality
    • DOI 10.1016/j.buildenv.2005.05.039, PII S0360132305002210
    • Mui KW et al: (2006). "Evaluation on sampling point densities for assessing indoor air quality." Building and Environment, 41, pp1515-1521. (Pubitemid 43842653)
    • (2006) Building and Environment , vol.41 , Issue.11 , pp. 1515-1521
    • Mui, K.W.1    Wong, L.T.2    Ho, W.L.3
  • 34
    • 61349122017 scopus 로고    scopus 로고
    • Winter indoor air quality, thermal comfort and acoustic performance of newly built secondary schools in England
    • Mumovic D et al (2009). "Winter indoor air quality, thermal comfort and acoustic performance of newly built secondary schools in England." Building and Environment, 44, pp1466-1477.
    • (2009) Building and Environment , vol.44 , pp. 1466-1477
    • Mumovic, D.1
  • 35
    • 84889678194 scopus 로고    scopus 로고
    • Distribution of carbon dioxide produced by people in a room: Part 2 - Field study
    • Coimbra, Portugal
    • Naydenov KG et al: (2004). "Distribution of Carbon Dioxide Produced by People in a Room: Part 2 - Field Study". Proceedings of Roomvent 2004 Coimbra, Portugal.
    • (2004) Proceedings of Roomvent 2004
    • Naydenov, K.G.1
  • 36
    • 0035726183 scopus 로고    scopus 로고
    • Determination of selected pollutants and measurement of physical parameters for the evaluation of indoor air quality in school buildings in Athens, Greece
    • Panayotis AS et al: (2001). "Determination of Selected Pollutants and Measurement of Physical Parameters for the Evaluation of Indoor Air Quality in School Buildings in Athens, Greece." Indoor and Built Environment, 10, (3-4), pp185-192.
    • (2001) Indoor and Built Environment , vol.10 , Issue.3-4 , pp. 185-192
    • Panayotis, A.S.1
  • 37
    • 0002000961 scopus 로고
    • Air change effectiveness measurements in two modern office buildings
    • Persily AK et al: (1994). "Air Change Effectiveness Measurements in Two Modern Office Buildings." Indoor Air, 4, pp40-55.
    • (1994) Indoor Air , vol.4 , pp. 40-55
    • Persily, A.K.1
  • 38
    • 64049093503 scopus 로고    scopus 로고
    • Transport of particulate and gaseous pollutants in the vicinity of a human body
    • Rim D and Novoselac A: (2009). "Transport of particulate and gaseous pollutants in the vicinity of a human body." Building and Environment, 44, (9), pp1840-1849.
    • (2009) Building and Environment , vol.44 , Issue.9 , pp. 1840-1849
    • Rim, D.1    Novoselac, A.2
  • 39
    • 0003656299 scopus 로고
    • Air flow patterns within buildings: Measurement techniques
    • Air Infiltration and Ventilation Centre, Belguim
    • Roulet C-A and Vandaele L: (1991). "Air flow patterns within buildings: Measurement techniques." AIVC Technical Note 34. Air Infiltration and Ventilation Centre, Belguim.
    • (1991) AIVC Technical Note 34
    • Roulet, C.-A.1    Vandaele, L.2
  • 40
    • 47549109830 scopus 로고    scopus 로고
    • Experimental investigation of the air flow and indoor carbon dioxide concentration in classrooms with intermittent natural ventilation
    • Santamouris M et al: (2008). "Experimental investigation of the air flow and indoor carbon dioxide concentration in classrooms with intermittent natural ventilation." Energy and Buildings, 40, (10), pp1833-1843.
    • (2008) Energy and Buildings , vol.40 , Issue.10 , pp. 1833-1843
    • Santamouris, M.1
  • 41
    • 0033207044 scopus 로고    scopus 로고
    • Measuring strategies and monitoring of the indoor environment
    • Schneider T: (1999). "Measuring strategies and monitoring of the indoor environment." Journal of Environment Monitoring, 1, pp427 - 434. (Pubitemid 129503287)
    • (1999) Journal of Environmental Monitoring , vol.1 , Issue.5 , pp. 427-434
    • Schneider, T.1
  • 42
    • 4544303076 scopus 로고    scopus 로고
    • 2 concentrations and student attendance in Washington and Idaho
    • DOI 10.1111/j.1600-0668.2004.00251.x
    • Shendell DG: et al: (2004). "Associations between classroom CO2 concentrations and student attendance in Washington and Idaho." Indoor Air, 14, (5), pp333-341. (Pubitemid 39237219)
    • (2004) Indoor Air , vol.14 , Issue.5 , pp. 333-341
    • Shendell, D.G.1    Prill, R.2    Fisk, W.J.3    Apte, M.G.4    Blake, D.5    Faulkner, D.6
  • 43
    • 2442597779 scopus 로고    scopus 로고
    • Evidence of inadequate ventilation in portable classrooms: Results of a pilot study in Los Angeles County
    • DOI 10.1111/j.1600-0668.2004.00235.x
    • Shendell DG et al: (2004). "Evidence of inadequate ventilation in portable classrooms: results of a pilot study in Los Angeles County." Indoor Air, 14, (3), pp154-158. (Pubitemid 38648646)
    • (2004) Indoor Air , vol.14 , Issue.3 , pp. 154-158
    • Shendell, D.G.1    Winer, A.M.2    Weker, R.3    Colome, S.D.4
  • 45
    • 0023828560 scopus 로고
    • Determination of ventilation rates in occupied buildings from metabolic CO2 concentrations and production rates
    • DOI 10.1016/0360-1323(88)90023-6
    • Smith PN: (1988). "Determination of ventilation rates in occupied buildings from metabolic CO2 concentrations and production rates." Building and Environment, 23, (2), pp95-102. (Pubitemid 18620653)
    • (1988) Building and Environment , vol.23 , Issue.2 , pp. 95-102
    • Smith, P.N.1
  • 46
    • 0032215251 scopus 로고    scopus 로고
    • Effect of contaminant properties and temperature gradients on the efficiency of transient gaseous contaminant removal from an enclosure: A numerical study
    • Soria M et al: (1998). "Effect of contaminant properties and temperature gradients on the efficiency of transient gaseous contaminant removal from an enclosure: a numerical study." Int J Heat Mass Transfer, 30, pp2609-3589.
    • (1998) Int J Heat Mass Transfer , vol.30 , pp. 2609-3589
    • Soria, M.1
  • 47
    • 27344440809 scopus 로고    scopus 로고
    • LEED and standard 62.1
    • American Society of Heating, Refrigerating and Air- Conditioning Engineers
    • Taylor ST: (2005). "LEED and Standard 62.1." American Society of Heating, Refrigerating and Air- Conditioning Engineers, ASHRAE Journal, 47, (9).
    • (2005) ASHRAE Journal , vol.47 , Issue.9
    • Taylor, S.T.1
  • 48
    • 0030774478 scopus 로고    scopus 로고
    • Nasal congestion in relation to low air exchange rate in schools. Evaluation by acoustic rhinometry
    • Walinder R et al: (1997). "Nasal Congestion in Relation to Low Air Exchange Rate in Schools: Evaluation by Acoustic Rhinometry." Acta Otolaryngologica, 117, (5), pp724-727. (Pubitemid 27418203)
    • (1997) Acta Oto-Laryngologica , vol.117 , Issue.5 , pp. 724-727
    • Walinder, R.1    Norback, D.2    Wieslander, G.3    Smedje, G.4    Erwall, C.5
  • 49
    • 39749138929 scopus 로고    scopus 로고
    • Characterizing and predicting ultrafine particle counts in Canadian classrooms during the winter months: Model development and evaluation
    • DOI 10.1016/j.envres.2007.08.013, PII S0013935107001843
    • Weichenthal S et al: (2008). "Characterizing and predicting ultrafine particle counts in Canadian classrooms during the winter months: Model development and evaluation." Environmental Research, 106, (3), pp349-360. (Pubitemid 351296203)
    • (2008) Environmental Research , vol.106 , Issue.3 , pp. 349-360
    • Weichenthal, S.1    Dufresne Andre2    Infante-Rivard, C.3    Joseph, L.4
  • 50
    • 33645210618 scopus 로고    scopus 로고
    • Gas cooking, kitchen ventilation, and exposure to combustion products
    • Willers SM et al: (2006). "Gas cooking, kitchen ventilation, and exposure to combustion products." Indoor Air, 16, pp65-73.
    • (2006) Indoor Air , vol.16 , pp. 65-73
    • Willers, S.M.1
  • 51
    • 17644387556 scopus 로고    scopus 로고
    • Comparative study of the indoor air quality of naturally ventilated and air-conditioned bedrooms of residential buildings in Singapore
    • DOI 10.1016/j.buildenv.2004.01.024, PII S0360132304000356
    • Wong NHNH and Huang B: (2004). "Comparative study of the indoor air quality of naturally ventilated and air-conditioned bedrooms of residential buildings in Singapore." Building and Environment, 39, (9), pp1115-1123. (Pubitemid 40564040)
    • (2004) Building and Environment , vol.39 , Issue.9 , pp. 1115-1123
    • Wong, N.H.1    Huang, B.2
  • 52
    • 55549123566 scopus 로고    scopus 로고
    • Indoor air quality investigation according to age of the school buildings in Korea
    • Yang W et al: (2009). "Indoor air quality investigation according to age of the school buildings in Korea." Journal of Environmental Management, 90, pp348-354.
    • (2009) Journal of Environmental Management , vol.90 , pp. 348-354
    • Yang, W.1
  • 53
    • 33750735028 scopus 로고    scopus 로고
    • A comparative study of asthma, pollen, cat and dog allergy among pupils and allergen levels in schools in Taiyuan city, China, and Uppsala, Sweden
    • Zhao ZH et al: (2006). "A comparative study of asthma, pollen, cat and dog allergy among pupils and allergen levels in schools in Taiyuan city, China, and Uppsala, Sweden." Indoor Air, 16, (6), 404-413.
    • (2006) Indoor Air , vol.16 , Issue.6 , pp. 404-413
    • Zh, Z.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.