메뉴 건너뛰기




Volumn 38, Issue 3, 2012, Pages 521-526

Power transformer condition assessment strategy using matter element analysis

Author keywords

Classical field; Condition assessment; Correlation function; Matter element analysis; Power transformer; Segment field

Indexed keywords

CLASSICAL FIELDS; CONDITION ASSESSMENTS; CORRELATION FUNCTION; MATTER-ELEMENT ANALYSIS; SEGMENT FIELD;

EID: 84859778206     PISSN: 10036520     EISSN: None     Source Type: Journal    
DOI: 10.3969/j.issn.1003-6520.2012.03.002     Document Type: Article
Times cited : (39)

References (21)
  • 1
    • 84859754685 scopus 로고    scopus 로고
    • ™-2006 IEEE guide for the evaluation and reconditioning of liquid immersed power transformers
    • ™-2006 IEEE guide for the evaluation and reconditioning of liquid immersed power transformers[S], 2007.
    • (2007)
  • 3
    • 40749122511 scopus 로고    scopus 로고
    • Condition assessment model for power transformer in service based on Fuzzy synthetic evaluation
    • LIAO Ruijin, WANG Qian, LUO Sijia, et al. Condition assessment model for power transformer in service based on Fuzzy synthetic evaluation[J]. Automation of Electric Power System, 2008, 32(3): 70-74.
    • (2008) Automation of Electric Power System , vol.32 , Issue.3 , pp. 70-74
    • Liao, R.1    Wang, Q.2    Luo, S.3
  • 4
    • 84859751173 scopus 로고    scopus 로고
    • Fuzzy synthetic evaluation of power transformer condition with variable weights
    • LUO Sijia, LIAO Ruijin, WANG Youyuan, et al. Fuzzy synthetic evaluation of power transformer condition with variable weights[J]. High Voltage Engineering, 2007, 37(8): 107-108.
    • (2007) High Voltage Engineering , vol.37 , Issue.8 , pp. 107-108
    • Luo, S.1    Liao, R.2    Wang, Y.3
  • 5
    • 79953225127 scopus 로고    scopus 로고
    • An integrated decision-making model for condition assessment of power transformers using Fuzzy approach and evidential reasoning
    • LIAO Ruijin, ZHENG Hanbo, Grzybowski, et al. An integrated decision-making model for condition assessment of power transformers using Fuzzy approach and evidential reasoning[J]. IEEE Transactions on Power Delivery, 2011, 26(2): 1111-1118.
    • (2011) IEEE Transactions on Power Delivery , vol.26 , Issue.2 , pp. 1111-1118
    • Liao, R.1    Zheng, H.2    Grzybowski3
  • 6
    • 78649977171 scopus 로고    scopus 로고
    • A power transformer insulation condition assessment method based on set pair analysis
    • LIAO Ruijin, ZHENG Hanbo, YANG Lijun, et al. A power transformer insulation condition assessment method based on set pair analysis [J]. Automation of Electric Power Systems, 2010, 34(21): 55-60.
    • (2010) Automation of Electric Power Systems , vol.34 , Issue.21 , pp. 55-60
    • Liao, R.1    Zheng, H.2    Yang, L.3
  • 7
    • 34248350401 scopus 로고    scopus 로고
    • A hierarchical grey evaluation model for operation condition of power transformers
    • XIONG Hao, SUN Caixin, ZHANG Yun, et al. A hierarchical grey evaluation model for operation condition of power transformers[J]. Automation of Electric Power System, 2007, 31(7): 55-60.
    • (2007) Automation of Electric Power System , vol.31 , Issue.7 , pp. 55-60
    • Xiong, H.1    Sun, C.2    Zhang, Y.3
  • 8
    • 63749095322 scopus 로고    scopus 로고
    • Evaluation of overhead transmission lines operation based on grey relation correlation
    • HAN Fuchun, ZHOU Linwei, JIA Leiliang et al. Evaluation of overhead transmission lines operation based on grey relation correlation[J]. High Voltage Engineering, 2009, 35(2): 339-402.
    • (2009) High Voltage Engineering , vol.35 , Issue.2 , pp. 339-402
    • Han, F.1    Zhou, L.2    Jia, L.3
  • 9
    • 51649105640 scopus 로고    scopus 로고
    • Method for insulative condition classification evaluation of power transformer based on weight coefficient grey target theory
    • ZHENG Ruirui, ZHAO Jiyin, WU Baochun, et al. Method for insulative condition classification evaluation of power transformer based on weight coefficient grey target theory[J]. Transactions of China Electrotechnical Society, 2008, 23(8): 60-66.
    • (2008) Transactions of China Electrotechnical Society , vol.23 , Issue.8 , pp. 60-66
    • Zheng, R.1    Zhao, J.2    Wu, B.3
  • 10
    • 77955785597 scopus 로고    scopus 로고
    • Neural network ensemble method and its application in DGA fault diagnosis of power transformer on the basis of active diverse learning
    • ZHANG Dongbo, XU Yu, WANG Yaonan, et al. Neural network ensemble method and its application in DGA fault diagnosis of power transformer on the basis of active diverse learning[J]. Proceedings of the CSEE, 2010, 30(22): 64-70.
    • (2010) Proceedings of the CSEE , vol.30 , Issue.22 , pp. 64-70
    • Zhang, D.1    Xu, Y.2    Wang, Y.3
  • 11
    • 49049107557 scopus 로고    scopus 로고
    • Fault diagnostic method for power transformer based on improved wavelet neural network algorithm
    • CHEN Weigen, PAN Chong, YUN Yuxin, et al. Fault diagnostic method for power transformer based on improved wavelet neural network algorithm[J]. Chinese Journal of Scientific Instrument. 2008, 29(7): 1489-1493.
    • (2008) Chinese Journal of Scientific Instrument , vol.29 , Issue.7 , pp. 1489-1493
    • Chen, W.1    Pan, C.2    Yun, Y.3
  • 12
    • 77950984915 scopus 로고    scopus 로고
    • Power transformer fault diagnosis using weighted Fuzzy kernel clustering
    • FU Yang, TIAN Zhenning, JIANG Yurong, et al. Power transformer fault diagnosis using weighted Fuzzy kernel clustering [J]. High Voltage Engineering, 2010, 36(2): 371-374.
    • (2010) High Voltage Engineering , vol.36 , Issue.2 , pp. 371-374
    • Fu, Y.1    Tian, Z.2    Jiang, Y.3
  • 13
    • 45949092195 scopus 로고    scopus 로고
    • Application of density-based clustering technology in diagnosis of DGA data of transformer
    • XIONG Hao, LI Weiguo, SONG Wei, et al. Application of density-based clustering technology in diagnosis of DGA data of transformer[J]. High Voltage Engineering, 2008, 34(5): 1022-1026.
    • (2008) High Voltage Engineering , vol.34 , Issue.5 , pp. 1022-1026
    • Xiong, H.1    Li, W.2    Song, W.3
  • 14
    • 45949084922 scopus 로고    scopus 로고
    • Condition assessment for power transformers by Bayes networks
    • ZHAO Wenqing, ZHU Yongli, JIANG Bo, et al. Condition assessment for power transformers by Bayes networks[J]. High Voltage Engineering, 2008, 34(5): 1032-1039.
    • (2008) High Voltage Engineering , vol.34 , Issue.5 , pp. 1032-1039
    • Zhao, W.1    Zhu, Y.2    Jiang, B.3
  • 15
    • 77955813861 scopus 로고    scopus 로고
    • Transformer fault diagnosis method using random forests and kernel principle component analysis
    • HU Qing, SUN Caixin, DU Lin, et al. Transformer fault diagnosis method using random forests and kernel principle component analysis[J]. High Voltage Engineering, 2010, 36(7): 1725-1729.
    • (2010) High Voltage Engineering , vol.36 , Issue.7 , pp. 1725-1729
    • Hu, Q.1    Sun, C.2    Du, L.3
  • 16
    • 79953812659 scopus 로고    scopus 로고
    • Power transformer fault diagnosis based on genetic support vector machine and gray artificial immune algorithm
    • ZHENG Ruirui, ZHAO Jiyin, ZHAO Tingting, et al. Power transformer fault diagnosis based on genetic support vector machine and gray artificial immune algorithm[J]. Proceedings of the CSEE, 2011, 31(7): 56-63.
    • (2011) Proceedings of the CSEE , vol.31 , Issue.7 , pp. 56-63
    • Zheng, R.1    Zhao, J.2    Zhao, T.3
  • 17
    • 77958097713 scopus 로고    scopus 로고
    • Power transformer fault diagnosis based on rough set theory and support vector machines
    • WU Zhongli, YANG Jian, ZHU Yongli, Power transformer fault diagnosis based on rough set theory and support vector machines. Power System Protection and Control. 2010, 38(18): 80-83.
    • (2010) Power System Protection and Control , vol.38 , Issue.18 , pp. 80-83
    • Wu, Z.1    Yang, J.2    Zhu, Y.3
  • 18
    • 84858780242 scopus 로고    scopus 로고
    • Application of rough set and bp neural network to transformer fault diagnosis
    • ZHANG Jingming, LIU Jianguo. Application of rough set and bp neural network to transformer fault diagnosis[J]. Transformer, 2009, 46(4): 18-21.
    • (2009) Transformer , vol.46 , Issue.4 , pp. 18-21
    • Zhang, J.1    Liu, J.2
  • 20
    • 84859777645 scopus 로고    scopus 로고
    • Effect of preventive test on state evaluation of power transformer
    • DENG Xiaoqiang. Effect of preventive test on state evaluation of power transformer[J]. Transformer, 2007, 44(9): 29-32.
    • (2007) Transformer , vol.44 , Issue.9 , pp. 29-32
    • Deng, X.1
  • 21
    • 0003698521 scopus 로고    scopus 로고
    • ™-2008 IEEE Guide for the Interpretation of Gases Generated in Oil-Immersed Transformers
    • ™-2008 IEEE Guide for the Interpretation of Gases Generated in Oil-Immersed Transformers[S], 2009.
    • (2009)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.