-
1
-
-
0029909341
-
The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz
-
DOI 10.1088/0031-9155/41/11/002
-
Gabriel S., Lau R. W., Gabriel C., The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz Physics in Medicine and Biology 1996 41 11 2251 2269 (Pubitemid 26376902)
-
(1996)
Physics in Medicine and Biology
, vol.41
, Issue.11
, pp. 2251-2269
-
-
Gabriel, S.1
Lau, R.W.2
Gabriel, C.3
-
2
-
-
0024240108
-
An assessment of dynamic images by applied potential tomography for monitoring pulmonary perfusion
-
DOI 10.1088/0143-0815/9/4A/015
-
McArdle F. J., Suggett A. J., Brown B. H., Barber D. C., An assessment of dynamic images by applied potential tomography for monitoring pulmonary perfusion Clinical Physics and Physiological Measurement A 1988 9 4 87 91 (Pubitemid 19020091)
-
(1988)
Clinical Physics and Physiological Measurement
, vol.9
, Issue.SUPPL. A
, pp. 87-91
-
-
McArdle, F.J.1
Suggett, A.J.2
Brown, B.H.3
Barber, D.C.4
-
3
-
-
0026477169
-
Blood flow imaging using electrical impedance tomography
-
Brown B. H., Leathard A., Sinton A., McArdle F. J., Smith R. W., Barber D. C., Blood flow imaging using electrical impedance tomography Clinical Physics and Physiological Measurement A 1992 13 175 179
-
(1992)
Clinical Physics and Physiological Measurement A
, vol.13
, pp. 175-179
-
-
Brown, B.H.1
Leathard, A.2
Sinton, A.3
McArdle, F.J.4
Smith, R.W.5
Barber, D.C.6
-
4
-
-
0029161783
-
A real-time electrical impedance tomograph
-
Edic P. M., Saulnier G. J., Newell J. C., Isaacson D., A real-time electrical impedance tomograph IEEE Transactions on Biomedical Engineering 1995 42 9 849 859
-
(1995)
IEEE Transactions on Biomedical Engineering
, vol.42
, Issue.9
, pp. 849-859
-
-
Edic, P.M.1
Saulnier, G.J.2
Newell, J.C.3
Isaacson, D.4
-
5
-
-
0035111736
-
Realistic 2D human thorax modelling for EIT
-
DOI 10.1088/0967-3334/22/1/310, PII S0967333401199132
-
Borsic A., McLeod C., Lionheart W. R. B., Kerrouche N., Realistic 2D human thorax modelling for EIT Physiological Measurement 2001 22 1 77 83 (Pubitemid 32186759)
-
(2001)
Physiological Measurement
, vol.22
, Issue.1
, pp. 77-83
-
-
Borsic, A.1
McLeod, C.2
Lionheart, W.3
Kerrouche, N.4
-
6
-
-
33745160014
-
Imaging cardiac activity by the D-bar method for electrical impedance tomography
-
Isaacson D., Mueller J. L., Newell J. C., Siltanen S., Imaging cardiac activity by the D-bar method for electrical impedance tomography Physiological Measurement 2006 27 5 43 50
-
(2006)
Physiological Measurement
, vol.27
, Issue.5
, pp. 43-50
-
-
Isaacson, D.1
Mueller, J.L.2
Newell, J.C.3
Siltanen, S.4
-
7
-
-
79955615935
-
Non-invasive monitoring of central blood pressure by electrical impedance tomography: First experimental evidence
-
Sol J., Adler A., Santos A., Tusman G., Sipmann F. S., Bohm S. H., Non-invasive monitoring of central blood pressure by electrical impedance tomography: first experimental evidence Medical and Biological Engineering and Computing 2011 49 4 409 415
-
(2011)
Medical and Biological Engineering and Computing
, vol.49
, Issue.4
, pp. 409-415
-
-
Sol, J.1
Adler, A.2
Santos, A.3
Tusman, G.4
Sipmann, F.S.5
Bohm, S.H.6
-
8
-
-
33748749612
-
Statistical inverse problems: Discretization, model reduction and inverse crimes
-
DOI 10.1016/j.cam.2005.09.027, PII S0377042705007296
-
Kaipio J., Somersalo E., Statistical inverse problems: discretization, model reduction and inverse crimes Journal of Computational and Applied Mathematics 2007 198 2 493 504 (Pubitemid 44402950)
-
(2007)
Journal of Computational and Applied Mathematics
, vol.198
, Issue.2
, pp. 493-504
-
-
Kaipio, J.1
Somersalo, E.2
-
9
-
-
33645778239
-
The inverse conductivity problem with an imperfectly known boundary
-
Kolehmainen V., Lassas M., Ola P., The inverse conductivity problem with an imperfectly known boundary SIAM Journal on Applied Mathematics 2005 66 2 365 383
-
(2005)
SIAM Journal on Applied Mathematics
, vol.66
, Issue.2
, pp. 365-383
-
-
Kolehmainen, V.1
Lassas, M.2
Ola, P.3
-
10
-
-
34447101159
-
A review of errors in multi-frequency EIT instrumentation
-
McEwan A., Cusick G., Holder D. S., A review of errors in multi-frequency EIT instrumentation Physiological Measurement 2007 28 7 197 215
-
(2007)
Physiological Measurement
, vol.28
, Issue.7
, pp. 197-215
-
-
McEwan, A.1
Cusick, G.2
Holder, D.S.3
-
11
-
-
79551577471
-
Compensation of modelling errors due to unknown domain boundary in electrical impedance tomography
-
Nissinen A., Kolehmainen V. P., Kaipio J. P., Compensation of modelling errors due to unknown domain boundary in electrical impedance tomography IEEE Transactions on Medical Imaging 2011 30 2 231 242
-
(2011)
IEEE Transactions on Medical Imaging
, vol.30
, Issue.2
, pp. 231-242
-
-
Nissinen, A.1
Kolehmainen, V.P.2
Kaipio, J.P.3
-
12
-
-
0035115430
-
Variability in the cardiac EIT image as a function of electrode position, lung volume and body position
-
DOI 10.1088/0967-3334/22/1/319, PII S096733340119982X
-
Patterson R. P., Zhang J., Mason L. I., Jerosch-Herold M., Variability in the cardiac EIT image as a function of electrode position, lung volume and body position Physiological Measurement 2001 22 1 159 166 (Pubitemid 32186768)
-
(2001)
Physiological Measurement
, vol.22
, Issue.1
, pp. 159-166
-
-
Patterson, R.P.1
Zhang, J.2
Mason, L.I.3
Jerosch-Herold, M.4
-
13
-
-
0033995055
-
Electrical impedance imaging at multiple frequencies in phantoms
-
DOI 10.1088/0967-3334/21/1/309, PII S0967333400101947
-
Kerner T. E., Williams D. B., Osterman K. S., Reiss F. R., Hartov A., Paulsen K. D., Electrical impedance imaging at multiple frequencies in phantoms Physiological Measurement 2000 21 1 67 77 (Pubitemid 30120672)
-
(2000)
Physiological Measurement
, vol.21
, Issue.1
, pp. 67-77
-
-
Kerner, T.E.1
Williams, D.B.2
Osterman, K.S.3
Reiss, F.R.4
Hartov, A.5
Paulsen, K.D.6
-
14
-
-
0023450162
-
Possible technique to measure ventricular volume using electrical impedance measurements with an oesophageal electrode
-
Patterson R. P., Possible technique to measure ventricular volume using electrical impedance measurements with an oesophageal electrode Medical amp; Biological Engineering amp; Computing 1987 25 6 677 679 (Pubitemid 18534493)
-
(1987)
Medical and Biological Engineering and Computing
, vol.25
, Issue.6
, pp. 677-679
-
-
Patterson, R.P.1
-
15
-
-
0021245225
-
'Failed intubation' in obstetric anaesthesia. An indication for use of the 'esophageal gastric tube airway'
-
Tunstall M. E., Geddes C., Failed intubation in obstetric anaesthesia. An indication for use of the esophageal gastric tube airway British Journal of Anaesthesia 1984 56 6 659 661 (Pubitemid 14083296)
-
(1984)
British Journal of Anaesthesia
, vol.56
, Issue.6
, pp. 659-661
-
-
Tunstall, M.E.1
Geddes, C.2
-
17
-
-
79958788911
-
A fully parallel multi-frequency EIT system with flexible electrode configuration: KHU Mark2
-
Oh T. I., Wi H., Kim D. Y., Yoo P. J., Woo E. J., A fully parallel multi-frequency EIT system with flexible electrode configuration: KHU Mark2 Physiological Measurement 2011 32 7 835 849
-
(2011)
Physiological Measurement
, vol.32
, Issue.7
, pp. 835-849
-
-
Oh, T.I.1
Wi, H.2
Kim, D.Y.3
Yoo, P.J.4
Woo, E.J.5
-
19
-
-
84859770073
-
Feasibility of using internal electrodes to improve the accuracy cardiac electrical impedance tomography
-
Bath, UK
-
Nasehi-Tehrani J., Thiagalingam A., Jin C., Feasibility of using internal electrodes to improve the accuracy cardiac electrical impedance tomography Proceedings of the EIT Conference 2011 Bath, UK
-
(2011)
Proceedings of the EIT Conference
-
-
Nasehi-Tehrani, J.1
Thiagalingam, A.2
Jin, C.3
-
20
-
-
33745137848
-
Uses and abuses of EIDORS: An extensible software base for EIT
-
Adler A., Lionheart W. R. B., Uses and abuses of EIDORS: an extensible software base for EIT Physiological Measurement 2006 27 5 25 42
-
(2006)
Physiological Measurement
, vol.27
, Issue.5
, pp. 25-42
-
-
Adler, A.1
Lionheart, W.R.B.2
-
21
-
-
70149113909
-
GREIT: A unified approach to 2D linear EIT reconstruction of lung images
-
Adler A., Arnold J. H., Bayford R., Borsic A., Brown B., Dixon P., Faes T. J. C., Frerichs I., Gagnon H., Grber Y., Grychtol B., Hahn G., Lionheart W. R. B., Malik A., Patterson R. P., Stocks J., Tizzard A., Weiler N., Wolf G. K., GREIT: a unified approach to 2D linear EIT reconstruction of lung images Physiological Measurement 2009 30 6 35 55
-
(2009)
Physiological Measurement
, vol.30
, Issue.6
, pp. 35-55
-
-
Adler, A.1
Arnold, J.H.2
Bayford, R.3
Borsic, A.4
Brown, B.5
Dixon, P.6
Faes, T.J.C.7
Frerichs, I.8
Gagnon, H.9
Grber, Y.10
Grychtol, B.11
Hahn, G.12
Lionheart, W.R.B.13
Malik, A.14
Patterson, R.P.15
Stocks, J.16
Tizzard, A.17
Weiler, N.18
Wolf, G.K.19
-
22
-
-
83655192011
-
L1 regularization method in electrical impedance tomography by using the L1-curve (Pareto frontier curve)
-
Nasehi-Tehrani J., McEwan A., Jin C., van Schaik A., L1 regularization method in electrical impedance tomography by using the L1-curve (Pareto frontier curve) Applied Mathematical Modelling 2012 36 3 1095 1105
-
(2012)
Applied Mathematical Modelling
, vol.36
, Issue.3
, pp. 1095-1105
-
-
Nasehi-Tehrani, J.1
McEwan, A.2
Jin, C.3
Van Schaik, A.4
-
23
-
-
0002621641
-
Electrical impedance tomography
-
PII S0036144598333613
-
Cheney M., Isaacson D., Newell J. C., Electrical impedance tomography SIAM Review 1999 41 1 85 101 (Pubitemid 129723749)
-
(1999)
SIAM Review
, vol.41
, Issue.1
, pp. 85-101
-
-
Cheney, M.1
Isaacson, D.2
Newell, J.C.3
-
24
-
-
0032034236
-
Tikhonov regularization and prior information in electrical impedance tomography
-
PII S0278006298049994
-
Vauhkonen M., Vadsz D., Karjalainen P. A., Somersalo E., Kaipio J. P., Tikhonov regularization and prior information in electrical impedance tomography IEEE Transactions on Medical Imaging 1998 17 2 285 293 (Pubitemid 128747681)
-
(1998)
IEEE Transactions on Medical Imaging
, vol.17
, Issue.2
, pp. 285-293
-
-
Vauhkonen, M.1
Vadasz, D.2
Karjalainen, P.A.3
Somersalo, E.4
Kaipio, J.P.5
-
25
-
-
0001300994
-
Solution of incorrectly formulated problems and the regularization method
-
Tikhonov A., Solution of incorrectly formulated problems and the regularization method English Translation of Dokl Akad Nauk SSSR 1963 4 1035- 1038
-
(1963)
English Translation of Dokl Akad Nauk SSSR
, vol.4
, pp. 1035-1038
-
-
Tikhonov, A.1
-
26
-
-
3042816350
-
Dynamic inverse obstacle problems with electrical impedance tomography
-
Kim K. Y., Kim B. S., Kim M. C., Kim S., Dynamic inverse obstacle problems with electrical impedance tomography Mathematics and Computers in Simulation 2004 66 4-5 399 408
-
(2004)
Mathematics and Computers in Simulation
, vol.66
, Issue.45
, pp. 399-408
-
-
Kim, K.Y.1
Kim, B.S.2
Kim, M.C.3
Kim, S.4
-
28
-
-
0028501213
-
Finite-element method in electrical impedance tomography
-
DOI 10.1007/BF02515311
-
Woo E. J., Hua P., Webster J. G., Tompkins W. J., Finite-element method in electrical impedance tomography Medical and Biological Engineering and Computing 1994 32 5 530 536 (Pubitemid 24316447)
-
(1994)
Medical and Biological Engineering and Computing
, vol.32
, Issue.5
, pp. 530-536
-
-
Woo, E.J.1
Hua, P.2
Webster, J.G.3
Tompkins, W.J.4
-
29
-
-
0029954935
-
The dielectric properties of biological tissues: I. Literature survey
-
DOI 10.1088/0031-9155/41/11/001
-
Gabriel C., Gabriel S., Corthout E., The dielectric properties of biological tissues: I. Literature survey Physics in Medicine and Biology 1996 41 11 2231 2249 (Pubitemid 26376901)
-
(1996)
Physics in Medicine and Biology
, vol.41
, Issue.11
, pp. 2231-2249
-
-
Gabriel, C.1
Gabriel, S.2
Corthout, E.3
-
30
-
-
34447093466
-
Numerical modelling errors in electrical impedance tomography
-
Dehghani H., Soleimani M., Numerical modelling errors in electrical impedance tomography Physiological Measurement 2007 28 7 45 55
-
(2007)
Physiological Measurement
, vol.28
, Issue.7
, pp. 45-55
-
-
Dehghani, H.1
Soleimani, M.2
-
31
-
-
1342332826
-
EIT reconstruction algorithms: Pitfalls, challenges and recent developments
-
DOI 10.1088/0967-3334/25/1/021
-
Lionheart W. R. B., EIT reconstruction algorithms: pitfalls, challenges and recent developments Physiological Measurement 2004 25 1 125 142 (Pubitemid 38252208)
-
(2004)
Physiological Measurement
, vol.25
, Issue.1
, pp. 125-142
-
-
Lionheart, W.R.B.1
-
32
-
-
0037762997
-
Evaluation of an EIT reconstruction algorithm using finite difference human thorax models as phantoms
-
DOI 10.1088/0967-3334/24/2/357, PII S0967333403549127
-
Patterson R. P., Zhang J., Evaluation of an EIT reconstruction algorithm using finite difference human thorax models as phantoms Physiological Measurement 2003 24 2 467 475 (Pubitemid 36648411)
-
(2003)
Physiological Measurement
, vol.24
, Issue.2
, pp. 467-475
-
-
Patterson, R.P.1
Zhang, J.2
-
33
-
-
84880765336
-
NETGEN: An advancing front 2D/3D mesh generator based on abstract rules
-
Schoberl J., NETGEN: an advancing front 2D/3D mesh generator based on abstract rules Computing and Visualization in Science 1997 1 1 41 52
-
(1997)
Computing and Visualization in Science
, vol.1
, Issue.1
, pp. 41-52
-
-
Schoberl, J.1
-
34
-
-
0000570697
-
Analysis of discrete Ill-posed problems by means of the L-curve
-
Hansen P. C., Analysis of discrete Ill-posed problems by means of the L-curve SIAM Review 1992 34 4 561 580
-
(1992)
SIAM Review
, vol.34
, Issue.4
, pp. 561-580
-
-
Hansen, P.C.1
-
35
-
-
0030126713
-
Electrical impedance tomography: Regularized imaging and contrast detection
-
PII S0278006296025359
-
Adler A., Guardo R., Electrical impedance tomography: regularized imaging and contrast detection IEEE Transactions on Medical Imaging 1996 15 2 170 179 (Pubitemid 126780309)
-
(1996)
IEEE Transactions on Medical Imaging
, vol.15
, Issue.2
, pp. 170-179
-
-
Adler, A.1
Guardo, R.2
-
36
-
-
0027611152
-
Robust image reconstruction algorithm and its parallel implementation in electrical impedance tomography
-
DOI 10.1109/42.232242
-
Woo E. J., Hua P., Webster J. G., Tompkins W. J., Robust image reconstruction algorithm and its parallel implementation in electrical impedance tomography IEEE Transactions on Medical Imaging 1993 12 2 137 146 (Pubitemid 23713257)
-
(1993)
IEEE Transactions on Medical Imaging
, vol.12
, Issue.2
, pp. 137-146
-
-
Woo, E.J.1
Hua, P.2
Webster, J.G.3
Tompkins, W.J.4
|